The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Modeling, analysis, and implementation of parallel multi-inverter systems with instantaneous average-current-sharing scheme
Abstract
Parallel multi-inverter systems can be designed to have the advantages of expandable output power, improved reliability, and easy N+X redundancy operation. However, a current-sharing control scheme has to be employed to enable the inverters to share the load current equally. A multi-inverter system with instantaneous average-current-sharing scheme is presented in this paper. By introducing a disturbance source to represent all the sources that may cause current unbalances, a model of the system can be built. Some key issues are discussed based on the model, including stability of the current-sharing controller, impedance characteristics and voltage regulation. Three experimental 110 VAC/1.1 kVA inverters are built and paralleled to verify the theoretical predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power electronics converters, applications and design
Robinson, F. V. P. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(97)87859-7 · Cited by 5,075
Rashid, R. (1988) · Cited by 2,662
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Levine, W. S. (2005) · Cited by 1,064
Impedance specifications for stable DC distributed power systems
Feng, X., Liu, J., & Lee, F. C. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988825 · Cited by 582
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.387992 · Cited by 520
Linear Control System Analysis and Design: Conventional and Modern
D’Azzo, J. J., & Houpis, C. H. (1995) · Virtual Defense Library (Ministerio de Defensa) · Cited by 432
Control topology options for single-phase UPS inverters
Ryan, M. J., Brumsickle, W. E., & Lorenz, R. D. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568015 · Cited by 429
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (2002) · Proceedings of IEEE Power Electronics Specialist Conference - PESC '93 · doi:10.1109/pesc.1993.472017 · Cited by 401
3C strategy for inverters in parallel operation achieving an equal current distribution
Wu, T.-F., Chen, Y.-K., & Huang, Y.-H. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.836342 · Cited by 269
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Control of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700
Metadata
- Authors
- Sun, X., Lee, Y.-S., & Xu, D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2003-05
- Volume
- 18
- Issue
- 3
- Pages
- 844-856
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2104834052
- Cited by
- 259
- References
- 10
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.