Abstract
This paper analyzes the effects of unbalanced voltage on doubly fed induction generators. It also presents a novel control strategy based on direct power control (DPC+) applied to this type of generators, predominant in wind energy applications, that enables them to work under perturbed conditions and achieve optimum results. Although the technique can be implemented to control both rotor converters and grid converters, we will hereby exemplify the former which regulates stator active and reactive power. The results obtained with DPC+ are then compared through experimental tests to indicate that the technique is suitable and achieves good dynamic responses while controlling current distortion, power or torque oscillations. The validation of results has been performed through experimental tests on a 20-kW generator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
Direct self-control (DSC) of inverter-fed induction machine
Depenbrock, M. (1988) · IEEE Transactions on Power Electronics · doi:10.1109/63.17963 · Cited by 1,705
High-performance direct torque control of an induction motor
Takahashi, I., & Ohmori, Y. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.25540 · Cited by 598 · cited 2×
“5) is made of four different modules which calculate: 1) the stator voltage symmetrical components and their angle in real time (2)–(5); 2) the positive and negative active and reactive power (10), (11); 3) the power (including the control strategy (23), (24) and feedback it; 4) the power error in order to feed the hy…”
BackgroundDefinitions of voltage unbalance
Pillay, P., & Manyage, M. (2001) · IEEE Power Engineering Review · doi:10.1109/39.920965 · Cited by 358
Symmetrical components in the time domain and their application to power network calculations
Paap, G. C. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.867135 · Cited by 310 · cited 2×
“The graphical meaning of this decomposition may be understood better if the three space vector voltage system is represented by Clarke transformation [16] in a stationary reference , and where the resulting elliptical trajectory is obtained by adding two vectors of circular trajectory (3), constant pulsation (see Fig.”
BackgroundMethodThree phase PWM converter/inverter by means of instantaneous active and reactive power control
Ohnishi, T. (2002) · Proceedings IECON '91: 1991 International Conference on Industrial Electronics, Control and Instrumentation · doi:10.1109/iecon.1991.239183 · Cited by 232
Understanding the unbalanced-voltage problem in wind turbine generation
Muljadi, E., Yıldırım, D., Batan, T., & Butterfield, C. P. (2003) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1999.801678 · Cited by 149
Phase frame analysis of the effects of voltage unbalance on induction machines
Kersting, W. H., & Phillips, W. H. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568004 · Cited by 109
Definitions of voltage unbalance
Bollen, M. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.1045567 · Cited by 86 · cited 1×
“This decomposition yields in (1) the “true unbalance” voltage factor which is very similar to NEMA or IEEE definitions [17], [ 18 ]”
MethodPrecise derating of three-phase induction motors with unbalanced voltages
Faiz, J., & Ebrahimpour, H. (2005) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2005.1518352 · Cited by 39 · cited 1×
“All of them show that even a slight unbalance has a high influence on rotor losses, which leads to calculate the necessary derating factor for the machine as presented in [5]–[7].”
Background
Cited by
Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Rodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681
Overview of Control Systems for the Operation of DFIGs in Wind Energy Applications
Cardenas, R., Pena, R., Alepuz, S., & Asher, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2243372 · Cited by 670
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions
Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2391436 · Cited by 201
“Likewise, advanced control functionalities for the power converters have also been proposed [17], [18].”
Background
Metadata
- Authors
- Santos-Martin, D., Rodriguez-Amenedo, J. L., & Arnalte, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-09
- Volume
- 23
- Issue
- 5
- Pages
- 2328-2336
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2139518216
- Cited by
- 190
- References
- 10
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.