The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Abstract
This paper presents an Energy Management System (EMS) for a stand-alone droop-controlled microgrid, which adjusts generators output power to minimize fuel consumption and also ensures stable operation. It has previously been shown that frequency-droop gains have a significant effect on stability in such microgrids. Relationship between these parameters and stability margins are therefore identified, using qualitative analysis and small-signal techniques. This allows them to be selected to ensure stability. Optimized generator outputs are then implemented in real-time by the EMS, through adjustments to droop characteristics within this constraint. Experimental results from a laboratory-sized microgrid confirm the EMS function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Self-citationDefining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Operation of a Multiagent System for Microgrid Control
Dimeas, A. L., & Hatziargyriou, N. D. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852060 · Cited by 1,031
Integration of distributed energy resources. The CERTS Microgrid Concept
Lasseter, R., Akhil, A., Marnay, C., Stephens, J., Dagle, J., Guttromsom, R., Meliopoulous, A. S., Yinger, R., & Eto, J. (2002) · doi:10.2172/799644 · Cited by 637
Fuel Consumption Minimization of a Microgrid
Hernandez-Aramburo, C. A., Green, T. C., & Mugniot, N. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847277 · Cited by 526
Self-citationUsing Low Voltage MicroGrids for Service Restoration
Moreira, C. L., Resende, F. O., & Lopes, J. A. P. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888989 · Cited by 290
Can microgrids make a major contribution to UK energy supply?
ABUSHARKH, S., ARNOLD, R., KOHLER, J., LI, R., MARKVART, T., ROSS, J., STEEMERS, K., WILSON, P., & YAO, R. (2006) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2004.09.013 · Cited by 285
Agent based micro grid management system
Oyarzabal, J., Jimeno, J., Ruela, J., Engler, A., & Hardt, C. (2005) · 2005 International Conference on Future Power Systems · doi:10.1109/fps.2005.204230 · Cited by 185
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“Small signal stability and eigenvalue analysis of converter-fed microgrids that are controlled based on droop characteristics have also been reported in the literature [82], [85], [93], [94], concluding that the dominant modes of the closed loop system are determined by droop controllers, and the overall stability of…”
BackgroundGuerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Metadata
- Authors
- Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-09
- Volume
- 23
- Issue
- 5
- Pages
- 2346-2352
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2111919291
- Cited by
- 733
- References
- 11
- FWCI
- 54.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.