A Fast and Accurate Synchronization Technique for Extraction of Symmetrical Components
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper introduces an approach for the real-time extraction of the frequency, phase angle, and symmetrical components of the grid signal, which is of great importance for many applications in power systems such as power quality and protection. The proposed method is based on the concept of the adaptive notch filter that provides a fast and accurate estimation of the symmetrical components in the presence of frequency and amplitude variations. In addition, the system offers a high degree of immunity and insensitivity to power system disturbances, harmonics, and other types of pollutions that exist in the grid signal. The simplicity of the structure makes the method suitable for both software and hardware implementations. Moreover, this very simple and very powerful tool can be used as a synchronization technique, which further simplifies the control issues currently challenging the integration of distributed energy technologies into the electricity grid. Mathematical derivations are presented to describe the principles of operation, and experimental results confirm the validity of the analytical work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“units with the utility systems and keep the generation up during the grid faults [ 2 ].”
BackgroundPower electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359 · cited 2×
“Among the improved versions, a DSRF-PLL [34], [35], which is based on the separation of the positive and negative sequences, is introduced as an optimal solution for utility grids with unbalanced voltages.”
BackgroundMethodA phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903 · cited 2×
“Moreover, phase-locked loop (PLL) based algorithms [ 21 ]–[30], filtering algorithms [31]–[34], and the decoupled double synchronous reference frame PLL (DDSRF-PLL) [35] have been introduced to extract the symmetrical components in order to handle the unbalance phenomenon.”
BackgroundYuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 896
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842 · cited 1×
“The SRF-PLL with a positive-sequence filter PLL (PSFPLL) [40], the SRF-PLL with a sinusoidal signal integrator PLL (SSI-PLL) [41], and the double second-order generalized integrator PLL (DSOGI-PLL) [42] are among the newly developed solutions to improve SRF-PLL performance.”
BackgroundFlexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Cited by
Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Rodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681
Guo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Addressing DC Component in PLL and Notch Filter Algorithms
Karimi-Ghartemani, M., Khajehoddin, S. A., Jain, P. K., Bakhshai, A., & Mojiri, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2158238 · Cited by 380
Self-citationWang, F., Duarte, J. L., & Hendrix, M. A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052289 · Cited by 327
Problems of Startup and Phase Jumps in PLL Systems
Ghartemani, M. K., Khajehoddin, S. A., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2169089 · Cited by 233
Self-citationFast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Saber, C., Labrousse, D., Revol, B., & Gascher, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2500958 · Cited by 73
Metadata
- Authors
- Yazdani, D., Mojiri, M., Bakhshai, A., & Joos, G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2009-03
- Volume
- 24
- Issue
- 3
- Pages
- 674-684
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2135291726
- Cited by
- 224
- References
- 24
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.