The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme
Abstract
This paper explores the impact of the output impedance on the active and reactive power flows between parallelized inverters operating with the droop method. In these systems, a virtual output impedance is usually added to the control loop of each inverter to improve the reactive power sharing, regardless of line-impedance unbalances and the sharing of nonlinear loads. The virtual impedance is usually implemented as the time derivative of the inverter output current, which makes the system highly sensitive to the output current noise and to nonlinear loads with high slew rate. To solve this, a second-order general-integrator (SOGI) scheme is proposed to implement the virtual impedance, which is less sensitive to the output current noise, avoids to perform the time derivative function, achieves better output-voltage total harmonic distortion, and enhances the sharing of nonlinear loads. Experimental results with two 2-kVA inverter systems under linear and nonlinear loads are provided to validate this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Self-citationA new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Self-citationGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Self-citationYao, W., Chen, M., Matas, J., Guerrero, J. M., & Qian, Z.-M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046001 · Cited by 844
Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 815
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Self-citation
Cited by
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
A review of droop control techniques for microgrid
Tayab, U. B., Roslan, M. A. B., Hwai, L. J., & Kashif, M. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.028 · Cited by 512
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454
Stability and Control Aspects of Microgrid Architectures–A Comprehensive Review
Ahmed, M., Meegahapola, L., Vahidnia, A., & Datta, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014977 · Cited by 326
Metadata
- Authors
- Alcala, J. M., Castilla, M., de Vicuña, L. G., Miret, J., & Vasquez, J. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 2993-3002
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2103319213
- Cited by
- 257
- References
- 13
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme. https://app.cochat.ai/papers/10.1109/tpel.2010.2082003
- The paper
- Alcala, J. M., Castilla, M., de Vicuña, L. G., Miret, J., & Vasquez, J. C. (2010). Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2082003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.