Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme

Alcala, José Matas, Castilla, Miguel, de Vicuña, Luis García, Miret, Jaume, Vasquez, Juan Carlos · 2010 · IEEE Transactions on Power Electronics

Abstract

This paper explores the impact of the output impedance on the active and reactive power flows between parallelized inverters operating with the droop method. In these systems, a virtual output impedance is usually added to the control loop of each inverter to improve the reactive power sharing, regardless of line-impedance unbalances and the sharing of nonlinear loads. The virtual impedance is usually implemented as the time derivative of the inverter output current, which makes the system highly sensitive to the output current noise and to nonlinear loads with high slew rate. To solve this, a second-order general-integrator (SOGI) scheme is proposed to implement the virtual impedance, which is less sensitive to the output current noise, avoids to perform the time derivative function, achieves better output-voltage total harmonic distortion, and enhances the sharing of nonlinear loads. Experimental results with two 2-kVA inverter systems under linear and nonlinear loads are provided to validate this approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2010.2082003

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 257

Metadata

Authors
Alcala, J. M., Castilla, M., de Vicuña, L. G., Miret, J., & Vasquez, J. C.
Venue
IEEE Transactions on Power Electronics
Published
2010-12
Volume
25
Issue
12
Pages
2993-3002
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2103319213
Cited by
257
References
13
FWCI
10.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme. https://app.cochat.ai/papers/10.1109/tpel.2010.2082003
The paper
Alcala, J. M., Castilla, M., de Vicuña, L. G., Miret, J., & Vasquez, J. C. (2010). Virtual Impedance Loop for Droop-Controlled Single-Phase Parallel Inverters Using a Second-Order General-Integrator Scheme. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2082003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.