Investigation Into IGBT dV/dt During Turn-Off and Its Temperature Dependence
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In many power converter applications, particularly those with high variable loads, such as traction and wind power, condition monitoring of the power semiconductor devices in the converter is considered desirable. Monitoring the device junction temperature in such converters is an essential part of this process. In this paper, a method for measuring the insulated gate bipolar transistor (IGBT) junction temperature using the collector voltagedV/dtat turn-OFF is outlined. A theoretical closed-form expression for thedV/dtat turn-OFF is derived, closely agreeing with experimental measurements. The role ofdV/dtin dynamic avalanche in high-voltage IGBTs is also discussed. Finally, the implications of the temperature dependence of thedV/dtare discussed, including implementation of such a temperature measurement technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“, [4]–[6], there still exists a need for condition monitoring of devices during the lifetime of the converter [7], [8].”
BackgroundSelf-citationReliability Prediction for Inverters in Hybrid Electrical Vehicles
Hirschmann, D., Tissen, D., Schroder, S., & De Doncker, R. W. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909236 · Cited by 209
Cited by
Ji, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329
Choi, U.-M., Blaabjerg, F., & Jorgensen, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2690500 · Cited by 248
Improved Reliability of Power Modules: A Review of Online Junction Temperature Measurement Methods
Baker, N., Liserre, M., Dupont, L., & Avenas, Y. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2312427 · Cited by 232
“High (each switching cycle) Good linearity Nanosecond or picoseconds per C [48], [49], [51], [52]”
BackgroundMethodCondition Monitoring Power Module Solder Fatigue Using Inverter Harmonic Identification
Xiang, D., Ran, L., Tavner, P., Yang, S., Bryant, A., & Mawby, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160988 · Cited by 174
Self-citationReal-Time Measurement of Temperature Sensitive Electrical Parameters in SiC Power MOSFETs
Griffo, A., Wang, J., Colombage, K., & Kamel, T. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2739687 · Cited by 175
“A number of studies have been published on the use of TSEPs for silicon (Si) MOSFETs and insulated gate bipolar transistors (IGBTs) power devices, including the monitoring of dI/dt during turn-ON or dV/dt during turn-OFF transients [14]–[16], Miller capacitance discharge time [17], threshold voltage [18]–[20], ON-stat…”
Background
Metadata
- Authors
- Bryant, A., Yang, S., Mawby, P., Xiang, D., Ran, L., Tavner, P., & Palmer, P.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-10
- Volume
- 26
- Issue
- 10
- Pages
- 3019-3031
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2166086202
- Cited by
- 235
- References
- 2
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.