Condition Monitoring Power Module Solder Fatigue Using Inverter Harmonic Identification
Abstract
Condition monitoring power semiconductor devices can inform converter maintenance and reduce damage. This paper presents a method to monitor solder fatigue in a voltage source inverter insulated gate bipolar transistor power module by detecting the change of an inverter output harmonic. It is shown that low-order harmonics, caused by nonideal switching, are affected by the device junction temperature, which in turn depends upon module solder condition. To improve the detection accuracy of the phenomenon, the inverter controller is set to cause harmonic resonance at the target harmonic frequency. The would-be resonance is suppressed by an outer control loop where the control action can be used as the condition monitoring signal. Simulation and experiment are presented to validate the method and evaluate its performance in operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
Self-citationSelected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Self-citation
Cited by
A Lifetime Estimation Technique for Voltage Source Inverters
Huang, H., & Mawby, P. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2229472 · Cited by 394
Self-citationA Digital Twin Based Estimation Method for Health Indicators of DC–DC Converters
Peng, Y., Zhao, S., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009600 · Cited by 305
Hanif, A., Yu, Y., DeVoto, D., & Khan, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2860587 · Cited by 272
Review of active thermal and lifetime control techniques for power electronic modules
Andresen, M., Liserre, M., & Buticchi, G. (2014) · 2014 16th European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910822 · Cited by 81
Metadata
- Authors
- Xiang, D., Ran, L., Tavner, P., Yang, S., Bryant, A., & Mawby, P.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-01
- Volume
- 27
- Issue
- 1
- Pages
- 235-247
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1966994623
- Cited by
- 174
- References
- 3
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condition Monitoring Power Module Solder Fatigue Using Inverter Harmonic Identification. https://app.cochat.ai/papers/10.1109/tpel.2011.2160988
- The paper
- Xiang, D., Ran, L., Tavner, P., Yang, S., Bryant, A., & Mawby, P. (2012). Condition Monitoring Power Module Solder Fatigue Using Inverter Harmonic Identification. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2160988
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.