Analysis and Design of a Bidirectional Isolated DC–DC Converter for Fuel Cells and Supercapacitors Hybrid System
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Electrical power systems in future uninterruptible power supplies or electrical vehicles may employ hybrid energy sources, such as fuel cells and supercapacitors. It will be necessary to efficiently draw the energy from these two sources as well as recharge the energy storage elements by the dc bus. In this paper, a bidirectional isolated dc-dc converter controlled by phase-shift angle and duty cycle for the fuel-cell hybrid energy system is analyzed and designed. The proposed topology minimizes the number of switches and their associated gate driver components by using two high-frequency transformers that combine a half-bridge circuit and a full-bridge circuit together on the primary side. The voltage doubler circuit is employed on the secondary side. The current-fed input can limit the input current ripple that is favorable for fuel cells. The parasitic capacitance of the switches is used for zero voltage switching (ZVS). Moreover, a phase-shift and duty-cycle modulation method is utilized to control the bidirectional power flow flexibly and it also makes the converter operate under a quasi-optimal condition over a wide input voltage range. This paper describes the operation principle of the proposed converter, the ZVS conditions, and the quasi-optimal design in depth. The design guidelines and considerations regarding the transformers and other key components are given. Finally, a 1-kW 30~50-V-input 400-V-output laboratory prototype operating at 100-kHz switching frequency is built and tested to verify the effectiveness of the presented converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Effects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438 · cited 2×
“Based on Dowell’s assumptions and the general field solutions for the distribution of current density in a single layer of an infinitely foil conductor, the expression for ac resistance of the mth layer was derived in [32] and [33] as”
BackgroundAn Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
Zhao, C., Round, S. D., & Kolar, J. W. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002056 · Cited by 900
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514 · cited 1×
“To increase the conversion efficiency, generally based on the precise mathematic model of the power loss of each component and the converter switching times, the phase-shift angle, and the duty cycle can be calculated to control the converter and make the total power losses minimal [31].”
MethodTransformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Krishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411 · cited 1×
“Converters using resonant tank or interleaved transformer windings were reported in [24] and [25], respectively.”
BackgroundModeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399 · cited 1×
“Based on the traditional half-bridge topology, a novel four-port converter with bidirectional ability was presented in [15] and [16].”
BackgroundA Systematic Approach to Synthesizing Multi-Input DC–DC Converters
Liu, Y.-C., & Chen, Y.-M. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2009170 · Cited by 399
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Jung, J.-H., Kim, H.-S., Ryu, M.-H., & Baek, J.-W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2213346 · Cited by 621
Emergence of hybrid energy storage systems in renewable energy and transport applications – A review
Hemmati, R., & Saboori, H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.029 · Cited by 423
Battery/Supercapacitors Combination in Uninterruptible Power Supply (UPS)
Lahyani, A., Venet, P., Guermazi, A., & Troudi, A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210736 · Cited by 355
Guo, W., Yu, C., Li, S., & Qiu, J. (2021) · Energy & Environmental Science · doi:10.1039/d0ee02649b · Cited by 344
Zhao, B., Song, Q., Liu, W., Liu, G., & Zhao, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2430934 · Cited by 302
Pan, X., Li, H., Liu, Y., Zhao, T., Ju, C., & Rathore, A. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2931739 · Cited by 215
“In addition to the topologies mentioned above, there are many other distinct types of current-fed converters which are out of common features [79]–[91].”
BackgroundZhao, B., Song, Q., Li, J., Liu, W., Liu, G., & Zhao, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2483543 · Cited by 175
“Moreover, many literatures discuss isolated bidirectional dc–dc converters (IBDCs), which are very important for achieving electrical isolation [9]–[12].”
BackgroundWang, Y., Song, Q., Zhao, B., Li, J., Sun, Q., & Liu, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2772833 · Cited by 71
Non-isolated bidirectional soft-switching SEPIC/ZETA converter with reduced ripple currents
Song, M.-S., Son, Y.-D., & Lee, K.-H. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.4.649 · Cited by 56
A bidirectional three-phase push–pull converter with dual asymmetrical PWM method
Kwon, M., Park, J., & Choi, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2431273 · Cited by 47
Bidirectional converter for high-efficiency fuel cell powertrain
Fardoun, A. A., Ismail, E. H., Sabzali, A. J., & Al-Saffar, M. A. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.10.122 · Cited by 38
Wang, Z., Su, X., Zeng, N., & Jiang, J. (2024) · Energies · doi:10.3390/en17102434 · Cited by 41
Metadata
- Authors
- Zhang, Z., Ouyang, Z., Thomsen, O. C., & Andersen, M. A. E.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 848-859
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2070623205
- Cited by
- 166
- References
- 30
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.