Effects of Magnetic Coupling of Nonadjacent Resonators on Wireless Power Domino-Resonator Systems
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
In this paper, the effects of the magnetic coupling of nonadjacent resonators on the optimal frequency of wireless power transfer are addressed. A power analysis has been carried out to identify the adjacent and nonadjacent power flow components. It is found that such cross-coupling effects of nonadjacent resonators would cause the maximum efficiency operation to slightly shift away from the resonance frequency of the resonators. Theoretical reasons for such phenomena are provided and experimentally confirmed with practical measurements in a wireless power transfer system comprising several magnetically coupled resonators arranged in a straight domino form.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A treatise on electricity and magnetism
(1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90053-8 · Cited by 9,077
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Hui, S. Y. R., & Ho, W. W. C. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.846550 · Cited by 501
Self-citationA contactless electrical energy transmission system for portable-telephone battery chargers
Jang, Y., & Jovanovic, M. M. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.812472 · Cited by 484
A Three-Phase Inductive Power Transfer System for Roadway-Powered Vehicles
Covic, G. A., Boys, J. T., Kissin, M. L. G., & Lu, H. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904025 · Cited by 439
Design of a contactless battery charger for cellular phone
Kim, C.-G., Seo, D.-H., You, J.-S., Park, J.-H., & Cho, B. H. (2001) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.969404 · Cited by 345
Imura, T., Okabe, H., & Hori, Y. (2009) · 2009 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2009.5289747 · Cited by 312
Choi, B., Nho, J., Cha, H., Ahn, T., & Choi, S. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822039 · Cited by 237
Wireless power transfer using weakly coupled magnetostatic resonators
Mur-Miranda, J. O., Fanti, G., Feng, Y., Omanakuttan, K., Ongie, R., Setjoadi, A., & Sharpe, N. (2010) · 2010 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2010.5617728 · Cited by 160
Liu, X., & Hui, S. (2007) · IEEE transactions on power electronics · doi:10.1109/tpel.2007.909301 · Cited by 159
Self-citation
Cited by
Wireless Power Transfer for Electric Vehicle Applications
Li, S., & Mi, C. C. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2319453 · Cited by 2,185
A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer
Hui, S. Y. R., Zhong, W., & Lee, C. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2249670 · Cited by 1,465
Self-citationA Double-Sided LCC Compensation Network and Its Tuning Method for Wireless Power Transfer
Li, S., Li, W., Deng, J., Nguyen, T. D., & Mi, C. C. (2015) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2347006 · Cited by 1,091
Wireless Charging Technologies: Fundamentals, Standards, and Network Applications
Lu, X., Wang, P., Niyato, D., Kim, D. I., & Han, Z. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2499783 · Cited by 968
An Adaptive Impedance-Matching Network Based on a Novel Capacitor Matrix for Wireless Power Transfer
Lim, Y., Tang, H., Lim, S., & Park, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292596 · Cited by 484
Maximum Energy Efficiency Tracking for Wireless Power Transfer Systems
Zhong, W. X., & Hui, S. Y. R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2351496 · Cited by 476
Self-citationModeling of Mutual Coupling Between Planar Inductors in Wireless Power Applications
Raju, S., Wu, R., Chan, M., & Yue, C. P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2253334 · Cited by 343
Barman, S. D., Reza, A. W., Kumar, N., Karim, M. E., & Munir, A. B. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.031 · Cited by 303
Control design for optimizing efficiency in inductive power transfer systems
Huang, Z., Wong, S.-C., & Tse, C. K. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2724039 · Cited by 242
Comparative Analysis of Two-Coil and Three-Coil Structures for Wireless Power Transfer
Zhang, J., Yuan, X., Wang, C., & He, Y. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2526780 · Cited by 186
“It has been reported that the cross-coupling effects of nonadjacent resonators would cause the maximum efficiency operation to shift away slightly from the resonance frequency in domino-resonator systems [24], and the source coil could induce a bifurcation phenomenon in the three-coil system [30]; therefore, if M02 ca…”
BackgroundReflexive Field Containment in Dynamic Inductive Power Transfer Systems
Lee, K., Pantic, Z., & Lukic, S. M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2287262 · Cited by 173
Wireless power transfer inspired by the modern trends in electromagnetics
Song, M., Belov, P., & Kapitanova, P. (2017) · Applied Physics Reviews · doi:10.1063/1.4981396 · Cited by 172
Abou Houran, M., Yang, X., & Chen, W. (2018) · Electronics · doi:10.3390/electronics7110296 · Cited by 170
“WPT systems can be categorized according to the number of coils, as shown in Figure 7, where they can be classified as follows: two-coil structure (2C) [64,113], three-coil structure (3C) [116,132], four-coil structure (4C) [119,122], and multi-coil structure (MC) [136,151,152].”
Background
Metadata
- Authors
- Lee, C. K., Zhong, W. X., & Hui, S. Y. R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-04
- Volume
- 27
- Issue
- 4
- Pages
- 1905-1916
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2021776814
- Cited by
- 309
- References
- 13
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.