Analysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
This paper presents a fault-tolerant powertrain topology for series hybrid electric vehicles (SHEVs). The introduction of a redundant phase-leg that is shared by three converters in a standard SHEV powertrain allows us to maximize the reliability improvement with minimal part-count increase. Therefore, the cost increase is kept to minimum as well. The new topology features fast response in fault detection and isolation, and postfault operation at rated power throughput. Two implementations of the fault-tolerant design are presented in conjunction with elaborated discussion of the operating principles, control schemes, and fault diagnostic methods. The substantially improved reliability over standard SHEV powertrains is demonstrated by analysis of the Markov reliability model. Time-domain simulation based on a Saber model has been conducted and the results have verified the feasibility and performance of the proposed SHEV drive system. A scaled-down laboratory prototype has been built and the experimental results further validate the robust fault detection/isolation scheme and uncompromised postfault performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, phase redundancy approaches [239], [309] have gained popularity due to their full fault recovery without oversizing the drive.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [309]
Citations
Cites
Khaligh, A., & Li, Z. (2010) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2010.2047877 · Cited by 1,817
Modern electric, hybrid electric, and fuel cell vehicles fundamentals, theory, and design
Ehsani, M., Gao, Y., & Emadi, A. (2005) · Cited by 1,613
Overview of Permanent-Magnet Brushless Drives for Electric and Hybrid Electric Vehicles
Chau, K. T., Chan, C. C., & Liu, C. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918403 · Cited by 1,496 · cited 12×
“The reduced reliability of HEVs not only discounts fuel-saving premium, but also increases repair time and repair cost.”
BackgroundInfluentialSurvey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861 · cited 1×
“In fact, aggregation of many power electronic devices into drive systems of vehicles may adversely affect reliability of the overall system [16], [17].”
BackgroundSelf-citationWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“Based on performance metrics proposed in [35], the new topology can obtain the post-”
BackgroundSystem Reliability Theory: Models, Statistical Methods, and Applications
Rausand, M., & Høyland, A. (1994) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316900 · Cited by 674
Modeling and Control of a Power-Split Hybrid Vehicle
Liu, J., & Peng, H. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2008.919447 · Cited by 662 · cited 1×
“ment [9]–[12], and control in the system level [13]–[15], while significantly less attention has been devoted to the reliability and fault mitigation of HEVs’ powertrains.”
BackgroundHegazy, O., Mierlo, J. V., & Lataire, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2183148 · Cited by 394 · cited 1×
“A literature survey conducted by the authors of this paper suggests that major research effort has been focused on power electronic converter topologies [2]–[7], design and control of traction motors related to HEVs [8], energy storage unit and energy manage-”
BackgroundInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Research works printed but not linked: 1
- hoyland, 1994, System Reliability Theory
Cited by
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
“I. INTRODUCTION POWER electronic converters—featuring higher efficiencyand higher power density—play an increasingly important role in adjustable-speed drives, utility interface of renewable energy resources, flexible high-voltage direct current (HVDC) transmission systems, and electric or hybrid electric vehicles (HE…”
BackgroundMethodFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2325891 · Cited by 258
“The fault-tolerant methods using an additional leg have also been proposed in many papers [8], [10], [14], [15].”
MethodModel-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Review on fault‐diagnosis and fault‐tolerance for DC–DC converters
Kumar, G. K., & Elangovan, D. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.0672 · Cited by 158
Zhang, G., Zhang, H., Huang, X., Wang, J., Yu, H., & Graaf, R. (2015) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2501354 · Cited by 138
Xing, Y., & Lv, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2952807 · Cited by 138
“In [22], a brake pressure estimation approach was developed to realize a fault-tolerant control for the EVs.”
MethodQuasi-Z-Source Inverter With a T-Type Converter in Normal and Failure Mode
Pires, V. F., Cordeiro, A., Foito, D., & Martins, J. F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2514979 · Cited by 115
“This area has been extensively studied in classical inverters [32]–[37], but most of these solutions require redundant extra-phase legs or branches and/or switches.”
BackgroundTousizadeh, M., Seng, H., Selvaraj, J. A.-L., Rahim, N. A., & Ooi, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2850006 · Cited by 124
Lv, C., Xing, Y., Lu, C., Liu, Y., Guo, H., Gao, H., & Cao, D. (2018) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2808359 · Cited by 119
Hu, K., Liu, Z., Yang, Y., Iannuzzo, F., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2994368 · Cited by 99
Garg, P., Essakiappan, S., Krishnamoorthy, H. S., & Enjeti, P. N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2361905 · Cited by 101
Tousizadeh, M., Seng, H., Selvaraj, J. A.-L., Rahim, N. A., & Ooi, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2884759 · Cited by 90
“If the fault is restricted to be within the inverter leg, fault tolerant can be achieved by connecting the motor terminal of the faulted inverter leg either to the midpoint of dc link [3]–[6], or to an auxiliary inverter leg [9], using configurations known”
MethodFarhadi, M., Fard, M. T., Abapour, M., & Hagh, M. T. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2683534 · Cited by 84
Kumar, V., & Fernandes, B. G. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2687126 · Cited by 90
E-Mobility — Advancements and Challenges
Adib, A., Shadmand, M. B., Shamsi, P., Afridi, K. K., Amirabadi, M., Fateh, F., Ferdowsi, M., Lehman, B., Lewis, L. H., Mirafzal, B., et al. (2019) · IEEE Access · doi:10.1109/access.2019.2953021 · Cited by 79
A new structure for multilevel inverters with fault-tolerant capability against open circuit faults
Choupan, R., Golshannavaz, S., Nazarpour, D., & Barmala, M. (2018) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.11.013 · Cited by 76
Event-Based Anomaly Detection Using a One-Class SVM for a Hybrid Electric Vehicle
Ji, Y., & Lee, H. (2022) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2022.3165526 · Cited by 71
Hajary, A., Kianinezhad, R., Seifossadat, S. G., Mortazavi, S. S., & Saffarian, A. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2901598 · Cited by 61
“THREE-PHASE induction motor drives have become one of the main devices in various high-performance industrial applications such as hybrid and electric vehicles, automotive powertrains, oil pumps, and renewable energy conversion systems [1]–[3].”
BackgroundAviña-Corral, V., Rangel‐Magdaleno, J., Barrón-Zambrano, J. H., & Rosales-Nunez, S. A. (2024) · Measurement · doi:10.1016/j.measurement.2024.114864 · Cited by 64
Fault Management Techniques to Enhance the Reliability of Power Electronic Converters: An Overview
Rahimpour, S., Husev, O. O., Vinnikov, D., Kurdkandi, N. V., & Tarzamni, H. (2023) · IEEE Access · doi:10.1109/access.2023.3242918 · Cited by 58
Moosavi, S. S., Djerdir, A., Ait‐Amirat, Y., Khaburi, D. A., & N’Diaye, A. (2015) · IET Electrical Systems in Transportation · doi:10.1049/iet-est.2014.0055 · Cited by 58
“In [15], a fault-tolerant power-train topology for SHEVs is presented.”
BackgroundFault Detection and Identification Scheme for Dual-Inverter Fed OEWIM Drive
Yang, S., Sun, X., Ma, M., Zhang, X., & Chang, L. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2922924 · Cited by 46
Online Open-Phase Fault Detection for Permanent Magnet Machines With Low Fault Harmonic Magnitudes
Yang, S.-C., Hsu, Y., Chou, P., Chen, G., & Jian, D.-R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2758752 · Cited by 42
Review of SiC MOSFET based three-phase inverter lifetime prediction
Ni, Z., Lyu, X., Yadav, O. P., & Cao, D. (2017) · 2017 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2017.7930819 · Cited by 40
“Others use Markov reliability model to analyze the lifetime of paralleled devices [16] or paralleled topologies [17] [18].”
MethodFault Diagnosis and Tolerance With Low Torque Ripple for Open-Switch Fault of IM Drives
Hu, K., Liu, Z., Tasiu, I. A., & Chen, T. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3006057 · Cited by 43
PM Synchronous Machine Drive Response to Asymmetrical Short-Circuit Faults
Choi, G., & Jahns, T. M. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2518992 · Cited by 37
Fault Diagnosis in Hybrid Electric Vehicle Regenerative Braking System
Sankavaram, C., Pattipati, B., Pattipati, K. R., Zhang, Y., & Howell, M. (2014) · IEEE Access · doi:10.1109/access.2014.2362756 · Cited by 39
“[17] discussed a fault-tolerant powertrain topology for series hybrid electric vehicles.”
BackgroundZhang, W., & Xu, D. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2844092 · Cited by 34
“As for extra bridge solutions, a redundant parallel bridge is added and shared by three main phases, which can achieve a better compromise between system costs and performance [10], [11].”
BackgroundA Mission Profile-Based Reliability Modeling Framework for Fault-Tolerant Electric Propulsion
Thurlbeck, A., & Cao, Y. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3144620 · Cited by 31
Akhtar, I., Jameel, M., Altamimi, A., & Kirmani, S. (2022) · IEEE Access · doi:10.1109/access.2022.3174365 · Cited by 28
“Furthermore, a general structure of charging station of electric vehicles has been proposed to know the power electronics based elements reliability in Electric vehicles [25] and hybrid Electric vehicles reliability observation is also important for design, control, planning and management of Electric vehicles[26],[27…”
BackgroundWang, J., Cai, Y., Chen, L., Shi, D., Wang, S., & Zhu, Z. (2020) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2020.3040777 · Cited by 22
Yang, S.-C., Chen, G., & Jian, D.-R. (2017) · IEEE Access · doi:10.1109/access.2017.2651113 · Cited by 23
“Conventional phase fault tolerant control relies on redundant phases in existing machines or redundant switching legs in standard inverters [15]–[18].”
BackgroundSwitch failure diagnosis based on inductor current observation for boost converters
Jamshidpour, E., Poure, P., & Saadate, S. (2016) · International Journal of Electronics · doi:10.1080/00207217.2016.1138243 · Cited by 24
“Failure in DC–DC power electronics has been subject to several studies (Wang et al., 2013; Wolfgang, 2007), as well as reliability of power electronics (Song & Wang, 2013a).”
BackgroundMethodInfluentialRecovering Partial Three-Level Operation in a T-Type Inverter With Fault Management Redundant Unit
Wang, B., Li, Z., Dong, M., Bai, Z., Krein, P. T., & Ma, H. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2972592 · Cited by 18
Self-citationJi, Y., Jeong, S., Cho, Y., Seo, H., Bang, J., Kim, J., & Lee, H. (2021) · Applied Sciences · doi:10.3390/app112110187 · Cited by 17
“In addition, the fault detection methods with simple logic based on hardware redundancies were proposed [8,11].”
MethodPM synchronous machine drive response to asymmetrical short-circuit faults
Choi, G., & Jahns, T. M. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953453 · Cited by 15
An Improved T-Type Multiphase Fault Tolerant Inverter With Preserved Rated Output
Kumar, B., & Peddapati, S. (2024) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2024.3391814 · Cited by 15
“In this work, reliability analysis of the converter is conducted using the Markov chain model [23], which is shown in Fig.”
MethodLoad and Source Battery Simulator Based on Z-Source Rectifier
Choi, S.-C., Lee, J.-H., Noh, Y.-S., Kim, D.-Y., Kim, B.-J., & Won, C.-Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2617742 · Cited by 15
Reliability comparison of fault-tolerant HVDC based modular multilevel converters
Alharbi, M., Bhattacharya, S., & Yousefpoor, N. (2017) · 2017 IEEE Power & Energy Society General Meeting · doi:10.1109/pesgm.2017.8274712 · Cited by 12
A Fault-Tolerant Switching Scheme for an Isolated DC/AC Matrix Converter
Tajfar, A., & Mazumder, S. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360706 · Cited by 12
Reliability Assessment of Fault-Tolerant Power Converters including Wear-Out Failure
Sangwongwanich, A., & Blaabjerg, F. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773367 · Cited by 14
Review of Fault Tolerant Multi-Motor Drive Topologies for Automotive Applications
Sakka, M. A., Geury, T., Baghdadi, M. E., Dhaens, M., Sakka, M. A., & Hegazy, O. (2022) · Energies · doi:10.3390/en15155529 · Cited by 13
Meyyappan, C., & Ravichandran, C. S. (2022) · Solar Energy · doi:10.1016/j.solener.2022.08.015 · Cited by 12
Impact of modulation schemes on DC-link capacitor of VSI in HEV applications
Yao, F., Geng, L., Janabi, A., & Wang, B. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8002186 · Cited by 11
“A large portion of current ripple from both backward circuit and forward circuit are absorbed by DC-link circuit so that there is less interference effect between input source and output load[1][2].”
BackgroundSelf-citationA Multiphase Fault-Tolerant MLI With Preserved Rated Output for Emergency Load Applications
Kumar, B., & Peddapati, S. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3302869 · Cited by 12
Performance Analysis of Fault-Tolerance Techniques Towards Solar Fed Cascaded Multilevel Inverter
Meyyappan, C., & Ravichandran, C. S. (2021) · International Conference on Computer Communication and Informatics (ICCCI) · doi:10.1109/iccci50826.2021.9402705 · Cited by 13
Device-Level Parallel-in-Time Simulation of MMC-Based Energy System for Electric Vehicles
Lyu, C., Lin, N., & Dinavahi, V. (2021) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2021.3081534 · Cited by 11
A new fault-tolerant control strategy for switch open-circuit fault in open-winding driving system
Cui, R., Fan, Y. J., Zhang, X., Zhu, W., & Cheng, M. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793131 · Cited by 8
“For short-circuit fault, adopting fuse to rapidly disconnect faulty phase can avoid secondary impact on the driving system [5].”
BackgroundFault diagnosis in non-isolated bidirectional half-bridge DC-DC converters
Ribeiro, E., Cardoso, A. J. M., & Boccaletti, C. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049174 · Cited by 8
“These methods can be generically assigned into two different categories, according to the type of data used for fault diagnostic [13]: methods based on the analysis of converter variables [8-16] and methods based on the power switches voltages and currents [17-19].”
Method(2016) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-4666-9429-3.ch011 · Cited by 7
Longitudinal Driver Intention Inference
Xing, Y., Lv, C., & Cao, D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819113-2.00007-5 · Cited by 8
Kousar, S., Aslam, F., Kausar, N., Pamucar, D. S., & Addis, G. M. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/3684727 · Cited by 6
“A fault-tolerant power train topology for series hybrid electric vehicles was discussed by Song and Wang [52].”
BackgroundA modified inverter topology for fault-tolerant direct torque control induction motor drive
Gupta, Y. B. S. S., & Rao, S. S. (2020) · International Journal of Electronics · doi:10.1080/00207217.2020.1756445 · Cited by 7
Post-fault operation of Multiphase Energy Generation System
Rolak, M., & Malinowski, M. (2015) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2015.7231089 · Cited by 5
“Similarly, some solutions devoted to multiphase machines have been proposed to assure increased level of redundancy for particular converter’s leg [17].”
BackgroundOpen-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power Generation System
Das, P. S., & Kim, K. (2015) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v6.i2.pp293-304 · Cited by 5
“A fault-tolerant powertrain for series hybrid electric vehicles with two different techniques has been studied [12].”
MethodModel-Based Dependability Analysis of Fail-Operational Electric Drivetrains
Ebner, C., Gorelik, K., & Zimmermann, A. (2020) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim43001.2020.9158882 · Cited by 6
“, for power converters [18], [19] or electrical machines [20].”
BackgroundMethodTopology and Control of Two-Stage Bidirectional AC/DC Fault Tolerant Converter
Li, J., Lv, H., Shang, S., & Jin, N. (2018) · International Conference on Information Science and Control Engineering · doi:10.1109/icisce.2018.00207 · Cited by 4
Open Circuit Fault Mitigation in a Nine-Level Modified Packed E-Cell Inverter
Khan, S. A., Sarwar, A., Tariq, M., Urooj, S., & Hossain, M. A. (2022) · Energies · doi:10.3390/en15217976 · Cited by 3
Bhakar, P. S., Kalaiselvi, J., Gorla, N. B. Y., & Pou, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3395796 · Cited by 5
“A solution for providing redundancy in a single-phase two-level inverter is through an additional phase leg, which involves two redundant switches and four additional connecting devices (such as TRIACs) [6], [7].”
BackgroundFault Diagnosis Techniques for Electrical Powertrain System- A Review
Ouamara, D., Maidi, A., Chaibet, A., & Boukhnifer, M. (2019) · International Conference on Applied Automation and Industrial Diagnostics (ICAAID) · doi:10.1109/icaaid.2019.8935003 · Cited by 4
“The power inverter contains static switches which can be affected by short circuits [7, 8] and/or open circuits [9, 10] fault types.”
BackgroundOptimization of Fail-Operational Vehicle Traction Battery System Design
Ebner, C., Gorelik, K., & Zimmermann, A. (2020) · IEEE International Symposium on Systems Engineering · doi:10.1109/isse49799.2020.9272023 · Cited by 4
Rolak, M. (2015) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2015.05.34 · Cited by 2
“However an another way to increase reliability is a utilization of redundant elements such a inverter branch [5], or whole redundant machine set [6] .”
BackgroundNaghavi, M., Ghanbari, M., Ebrahimi, R., Jannati, M., & Sutikno, T. (2023) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v14.i2.pp809-818 · Cited by 1
Recognition of Driver Braking Intensity of EHB System Using a Hybrid Learning Approach
Yang, H., Kaku, C., & Yu, F. (2020) · IEEE Intelligent Vehicles Symposium · doi:10.1109/iv47402.2020.9304805 · Cited by 1
“In [4, 5], a fault tolerant control method in response to brake pressure sensor failure of EHB system was developed.”
MethodKumar, K. S., & Lavanya, V. U. P. (2022) · Advances in transdisciplinary engineering · doi:10.3233/atde220754 · Cited by 2
Abdelghani, H. B. (2016) · theses.fr (ABES) · doi:10.70675/7608b1adz029dz45f7z89f3z9afbbda80e36 · Cited by 4
A FAULT-TOLERANT HYBRID ELECTRIC VEHICLE POWERTRAIN
Song, Y., & Wang, B. (2013) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2024-01-3418
Self-citationYelamarthi, B. S. S. G., & Sandepudi, S. R. (2019) · 2019 International Conference on Power Electronics, Control and Automation (ICPECA) · doi:10.1109/icpeca47973.2019.8975479
“Once the fault is isolated, reconfiguration of the inverter is done automatically and post-fault control technique has to apply for restoring normal operation [7-25].”
BackgroundMethodAn adaptive, observer-based switching method for B4 inverters feeding three-phase induction motors
Holagh, H. V., Najafabadi, T. A., & Safamehr, H. (2021) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2021-0061
An Improved Secondary Fault-Tolerant Inverter and its Control Strategy
Li, Y., Yang, Z., & Cheng, X. Y. (2021) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc52312.2021.9602513
Fault‐Tolerant Converter Design for Photovoltaic System
Malik, A., & Haque, A. (2022) · Wiley eBooks · doi:10.1002/9781119873785.ch8
Submodule Fault-Tolerant Strategy for Modular Multilevel Converter with Scalable Control Structure
Alharbi, M., Isik, S., & Bhattacharya, S. (2022) · Sustainability · doi:10.3390/su142416445
“To validate the effectiveness of the proposed design, the Markov model, which is fundamentally explained in [30], is used to evaluate the reliability of the MMC system under different MMC designs.”
MethodVenkedesh, R. (2024) · International Journal of Electrical and Electronics Engineering · doi:10.14445/23488379/ijeee-v11i3p108
“The isolation of the defective components is done by using additional components such as TRIACs [33-35] and fuses [36].”
MethodA Fault-Tolerant Single-Phase Inverter Using Redundant Leg
Tripathi, A., Bhakar, P. S., & Kalaisel, J. (2024) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intelec60315.2024.10679020
Wang, H., Chen, M., Li, G., Zheng, M., & Hu, C. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3543535
“In contrast, hardware redundancy can ensure effective system operation [15], [16], [17], [18], [19].”
Transition and Fault-Tolerant Scheme for Single-Phase Inverter
Bhakar, P. S., Gorla, N. B. Y., & Kalaiselvi, J. (2024) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes61459.2024.10961398
“The simplest approach for adding redundancy to inverters is to introduce an extra leg [12].”
Wang, Z., Xu, P., Weng, X., & Zheng, Y. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3578523
“To achieve safety requirements derived from those hazards, many studies have investigated improving the safety performance of the motor driver through FTC strategies using open circuit (OC) and active short circuit (ASC) methods [16], [17], [18], [19], [20], [21], [22], [23], [24].”
Observation et commande tolérantes aux fautes de la dynamique latérale d'un véhicule
Alaridh, I. (2019) · theses.fr (ABES) · doi:10.70675/9b5d4e2bz2a6dz4391z9c7cz562f2b80b8d0
Reliability Improvements in Dual Traction Inverters for Hybrid Electric Vehicles
Ye, H. (2014) · MacSphere (McMaster University) · doi:10.71548/11579 · Cited by 1
Metadata
- Authors
- Song, Y., & Wang, B.
- Affiliations
- Michigan State University (US)
- ORCID
- Wang, Bingsen
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-12
- Volume
- 28
- Issue
- 12
- Pages
- 5854-5864
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2001075346
- Cited by
- 81
- References
- 41
- Citations by year
- 2025: 2 · 2024: 6 · 2023: 3 · 2022: 12 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 6 · 2017: 8 · 2016: 8 · 2015: 5 · 2014: 8 · 2013: 1
- FWCI
- 11.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Automotive Engineering › Electric and Hybrid Vehicle Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- series hybrid electric vehicle, converter redundancy, fault detection and isolation, Markov reliability model, fault diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.