High-Efficiency Transcutaneous Energy Transfer for Implantable Mechanical Heart Support Systems
Abstract
Inductive power transfer technology is a promising solution for powering implantable mechanical circulatory support systems, due to the elimination of the percutaneous driveline, which is still the major cause of severe infections. However, at the present time, no transcutaneous energy transfer (TET) system is commercially available and ready for long-term use. Specifically, the heating of the tissue due to power losses in the TET coils and the implanted electronic components are a major problem. The focus of this paper is, therefore, on the design and realization of a highly efficient TET system and the minimization of the power losses in the implanted circuits in particular. Parameter sweeps are performed in order to find the optimal energy transmission coil parameters. In addition, simple and meaningful design equations for optimal load matching are presented together with a detailed mathematical model of the power electronic stages. To achieve highest efficiencies, a high-frequency self-driven synchronous rectifier circuit with minimized volume is developed. Extensive measurements are carried out to validate the mathematical models and to characterize the performance of the prototype system. The optimized system is capable of transmitting 30 W of power with an efficiency greater than 95 %, even at a coil separation distance of 20 mm (0.79 in) and 70 mm (2.76 in) coil diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Powering an Artificial Heart: Birth of the Inductively Coupled–Radio Frequency System in 1960
Schuder, J. C. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.07130.x · Cited by 106
Cited by
Vu, V.-B., Tran, D.-H., & Choi, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2766605 · Cited by 450
Multi-Objective Optimization of 50 kW/85 kHz IPT System for Public Transport
Bosshard, R., & Kolar, J. W. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2598755 · Cited by 317
Self-citationRoy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“56 70 doutT = 100 doutR = 18 [30] 2015 2 MHz 1450 27 80 doutT = 140 doutR = 65 [80] 2015 800 kHz 30 w 95 20 doutT = 70 doutR = 34 [81] 2012 742 kHz 85 0–50 doutT = 38 doutR = 16.”
Near-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Metadata
- Authors
- Knecht, O., Bosshard, R., & Kolar, J. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-11
- Volume
- 30
- Issue
- 11
- Pages
- 6221-6236
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2068636597
- Cited by
- 186
- References
- 1
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Efficiency Transcutaneous Energy Transfer for Implantable Mechanical Heart Support Systems. https://app.cochat.ai/papers/10.1109/tpel.2015.2396194
- The paper
- Knecht, O., Bosshard, R., & Kolar, J. W. (2015). High-Efficiency Transcutaneous Energy Transfer for Implantable Mechanical Heart Support Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2015.2396194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.