High-Efficiency Transcutaneous Energy Transfer for Implantable Mechanical Heart Support Systems
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Inductive power transfer technology is a promising solution for powering implantable mechanical circulatory support systems, due to the elimination of the percutaneous driveline, which is still the major cause of severe infections. However, at the present time, no transcutaneous energy transfer (TET) system is commercially available and ready for long-term use. Specifically, the heating of the tissue due to power losses in the TET coils and the implanted electronic components are a major problem. The focus of this paper is, therefore, on the design and realization of a highly efficient TET system and the minimization of the power losses in the implanted circuits in particular. Parameter sweeps are performed in order to find the optimal energy transmission coil parameters. In addition, simple and meaningful design equations for optimal load matching are presented together with a detailed mathematical model of the power electronic stages. To achieve highest efficiencies, a high-frequency self-driven synchronous rectifier circuit with minimized volume is developed. Extensive measurements are carried out to validate the mathematical models and to characterize the performance of the prototype system. The optimized system is capable of transmitting 30 W of power with an efficiency greater than 95 %, even at a coil separation distance of 20 mm (0.79 in) and 70 mm (2.76 in) coil diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of half-bridge resonant converter topologies
Steigerwald, R. L. (1988) · IEEE Transactions on Power Electronics · doi:10.1109/63.4347 · Cited by 1,972 · cited 1×
“According to [25], the simplified equivalent load R̃L,eq is used to model the actual load together with the full-wave rectifier”
MethodWang, C.-S., Covic, G. A., & Stielau, O. H. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822038 · Cited by 1,213 · cited 1×
“In a preliminary step, four promising topologies, known from previous literature [5], [16]–[21], the series-series (SS), series– parallel (SP) and the series-series-parallel (SSP) compensation as well as the SS compensated topology operated at conditions for load independent unity voltage gain (SSU) were studied and c…”
BackgroundZhang, W., Wong, S.-C., Tse, C. K., & Chen, Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2249112 · Cited by 505 · cited 1×
“The peak gain resonance frequency of the system is at fr = f0 √ 1 − k0 and is below the operating frequency f0 , which is known as operating point with load independent voltage gain and is explained in detail in [5], [17], and [20].”
BackgroundBosshard, R., Kolar, J. W., Muhlethaler, J., Stevanovic, I., Wunsch, B., & Canales, F. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2311302 · Cited by 411 · cited 3×
“It was shown in [21], [22] and [24] that the energy transmission efficiency of an IPT system is a maximum, if the load is matched to the secondary side inductance.”
BackgroundMethodSelf-citationZhang, W., Wong, S.-C., Tse, C. K., & Chen, Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273364 · Cited by 406
Analysis, Design, and Control of a Transcutaneous Power Regulator for Artificial Hearts
Chen, Q., Wong, S. C., Tse, C. K., & Ruan, X. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2006492 · Cited by 244 · cited 2×
“The peak gain resonance frequency of the system is at fr = f0 √ 1 − k0 and is below the operating frequency f0 , which is known as operating point with load independent voltage gain and is explained in detail in [5], [17], and [20].”
BackgroundInductive Powering: Basic Theory and Application to Biomedical Systems
Schuylenbergh, K. V., & Puers, R. (2009) · Medical Entomology and Zoology · Cited by 240
Modeling and optimization of bidirectional dual active bridge DC-DC converter topologies
Krismer, F. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-006395373 · Cited by 230
Modeling and multi-objective optimization of inductive power components
Mühlethaler, J. (2012) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-007328104 · Cited by 159 · cited 2×
“The parasitic resistances RL1 and RL2 of the energy transmission coils can be measured at the operating frequency or calculated using FE analysis and analytical models as it is explained in [26].”
MethodLCL Pickup Circulating Current Controller for Inductive Power Transfer Systems
Huang, C.-Y., Boys, J. T., & Covic, G. A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199132 · Cited by 114 · cited 1×
“Another possibility to control the transferred energy is to estimate the coil coupling and the system output voltage from the measurement of the primary side operating conditions as it is reported in [14] or by the direct control of the received amount of power on the secondary side [15].”
Background
Cited by
Vu, V.-B., Tran, D.-H., & Choi, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2766605 · Cited by 450
Multi-Objective Optimization of 50 kW/85 kHz IPT System for Public Transport
Bosshard, R., & Kolar, J. W. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2598755 · Cited by 317
Self-citationRoy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Jiang, Y., Wang, L., Wang, Y., Liu, J., Li, X., & Ning, G. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2795523 · Cited by 189
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“56 70 doutT = 100 doutR = 18 [30] 2015 2 MHz 1450 27 80 doutT = 140 doutR = 65 [80] 2015 800 kHz 30 w 95 20 doutT = 70 doutR = 34 [81] 2012 742 kHz 85 0–50 doutT = 38 doutR = 16.”
Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial
Schormans, M., Valente, V., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2846020 · Cited by 170
“Particularly in the case of high power delivery, the total system efficiency can be >95% [26].”
BackgroundNear-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Metadata
- Authors
- Knecht, O., Bosshard, R., & Kolar, J. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-11
- Volume
- 30
- Issue
- 11
- Pages
- 6221-6236
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2068636597
- Cited by
- 186
- References
- 21
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.