The DOI matches its Crossref record.
A Fault Clearing Method in Converter-Dominated Microgrids With Conventional Protection Means
Abstract
The integration of converter-interfaced distributed generation in microgrids has raised several technical issues, including the successful operation of protective devices during faults. The protection issue is associated with the lack of large current injection during a fault, due to limits imposed by the semiconductor switches. This paper proposes a fault-detection and clearing control strategy method for symmetrical and asymmetrical line faults in a looped microgrid. The protection devices are simple overcurrent devices with the same settings, due to the looped microgrid topology. The proposed method is applied without using any kind of physical communication. The fault is detected by measuring indirectly the microgrid impedance. After the fault identification, the distributed energy resources (DERs) adjust their control in order to inject a current proportional to the measured microgrid impedance, according to a droop curve. This means that the DER closer to the fault injects a relatively larger current, achieving by this way a selective coordination of the protection means. The effectiveness of the proposed control strategy is evaluated through detailed simulation and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959085 · Cited by 256
Metadata
- Authors
- Oureilidis, K. O., & Demoulias, C. S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-06
- Volume
- 31
- Issue
- 6
- Pages
- 4628-4640
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2242939248
- Cited by
- 199
- References
- 0
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fault Clearing Method in Converter-Dominated Microgrids With Conventional Protection Means. https://app.cochat.ai/papers/10.1109/tpel.2015.2476702
- The paper
- Oureilidis, K. O., & Demoulias, C. S. (2016). A Fault Clearing Method in Converter-Dominated Microgrids With Conventional Protection Means. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2015.2476702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.