A Fault Clearing Method in Converter-Dominated Microgrids With Conventional Protection Means
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The integration of converter-interfaced distributed generation in microgrids has raised several technical issues, including the successful operation of protective devices during faults. The protection issue is associated with the lack of large current injection during a fault, due to limits imposed by the semiconductor switches. This paper proposes a fault-detection and clearing control strategy method for symmetrical and asymmetrical line faults in a looped microgrid. The protection devices are simple overcurrent devices with the same settings, due to the looped microgrid topology. The proposed method is applied without using any kind of physical communication. The fault is detected by measuring indirectly the microgrid impedance. After the fault identification, the distributed energy resources (DERs) adjust their control in order to inject a current proportional to the measured microgrid impedance, according to a droop curve. This means that the DER closer to the fault injects a relatively larger current, achieving by this way a selective coordination of the protection means. The effectiveness of the proposed control strategy is evaluated through detailed simulation and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 1×
“Due to the renewable energy growth, the microgrids present a high proliferation of dc/ac and ac/dc/ac converters [2].”
BackgroundDecoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359 · cited 13×
“3(b), the angle θPLL results from the error of the d-axis component of the voltage Vmgd .”
MethodInfluentialMohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230 · cited 1×
“2476702 control philosophy [4].”
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189 · cited 1×
“The detection of an asymmetrical fault can be implemented with the above presented fault-detection method, by using an orthogonal signal generator second-order generalized integrator (OSG-SOGI) PLL for each phase [33], [34].”
MethodRodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681 · cited 1×
“The detection of an asymmetrical fault can be implemented with the above presented fault-detection method, by using an orthogonal signal generator second-order generalized integrator (OSG-SOGI) PLL for each phase [33], [34].”
MethodBrahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.820204 · Cited by 679
Wireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters
Guerrero, J. M., Matas, J., Garcia De Vicunagarcia De Vicuna, L., Castilla, M., & Miret, J. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882015 · Cited by 662 · cited 1×
“2, in order to minimize the circulating currents among the connected DERs [27], [28].”
BackgroundMicrogrid Protection Using Communication-Assisted Digital Relays
Sortomme, E., Venkata, S. S., & Mitra, J. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2035810 · Cited by 537
An Islanding Microgrid Power Sharing Approach Using Enhanced Virtual Impedance Control Scheme
He, J., Li, Y. W., Guerrero, J. M., Blaabjerg, F., & Vasquez, J. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2243757 · Cited by 482 · cited 1×
“2, in order to minimize the circulating currents among the connected DERs [27], [28].”
BackgroundProtection Principles for Future Microgrids
Laaksonen, H. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2066990 · Cited by 380 · cited 1×
“These requirements present new challenges to meliorate the control strategy and tackle with the protection issues in microgrids consisting of converter-interfaced sources [3].”
Background
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959085 · Cited by 256
Current limiting algorithms and transient stability analysis of grid-forming VSCs
Qoria, T., Gruson, F., Colas, F., Kestelyn, X., & Guillaud, X. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106726 · Cited by 249
“To avoid this instability issue, some papers proposed to switch from voltage control based on the droop control to current control based on a phase-locked loop [1], [17].”
BackgroundLiu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
Habib, H. F., Lashway, C. R., & Mohammed, O. A. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2776858 · Cited by 167
“and energy storage devices (ESDs) are constantly connected and disconnected [4], [5].”
BackgroundAn Adaptive Fault Ride-Through Scheme for Grid-Forming Inverters Under Asymmetrical Grid Faults
Li, Z., Chan, K. W., Hu, J., & Or, S. W. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3135641 · Cited by 121
Huang, L., Wu, C., Zhou, D., & Blaabjerg, F. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3199906 · Cited by 107
Metadata
- Authors
- Oureilidis, K. O., & Demoulias, C. S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-06
- Volume
- 31
- Issue
- 6
- Pages
- 4628-4640
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2242939248
- Cited by
- 199
- References
- 14
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.