The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Critical Clearing Time Determination and Enhancement of Grid-Forming Converters Embedding Virtual Impedance as Current Limitation Algorithm
Open accessAbstract
This article deals with the postfault synchronization of a voltage source converter based on the droop control. In the case of large disturbances on the grid, the current is limited via current limitation algorithms such as the virtual impedance. During the fault, the power converter internal frequency deviates, resulting in a converter angle divergence. Thereby, the system may lose the synchronism after fault clearing and which may lead to instability. Hence, this article proposes a theoretical approach to explain the dynamic behavior of the grid-forming converter subject to a three-phase bolted fault. A literal expression of the critical clearing time is defined. Due to the precise analysis of the phenomenon, a simple algorithm can be derived to enhance the transient stability. It is based on adaptive gain included in the droop control. These objectives have been achieved with no external information and without switching from one control to the other. To prove the effectiveness of the developed control, experimental test cases have been performed in different faulted conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602
Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators
Paquette, A. D., & Divan, D. M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2345877 · Cited by 580
An Enhanced Microgrid Load Demand Sharing Strategy
He, J., & Li, Y. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2190099 · Cited by 429
Poolla, B. K., Gros, D., & Dorfler, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892290 · Cited by 400
An Improved Droop Control Strategy for Reactive Power Sharing in Islanded Microgrid
Han, H., Liu, Y., Sun, Y., Su, M., & Guerrero, J. M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2332181 · Cited by 301
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2521325 · Cited by 299
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“Simulation tests of the virtual impedance with inner-loop control [65] and without inner-loop control [20] are conducted.”
BackgroundRokrok, E., Qoria, T., Bruyere, A., Francois, B., & Guillaud, X. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3107959 · Cited by 311
Self-citation
Metadata
- Authors
- Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2020-06
- Volume
- 8
- Issue
- 2
- Pages
- 1050-1061
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2996528132
- Cited by
- 256
- References
- 20
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Critical Clearing Time Determination and Enhancement of Grid-Forming Converters Embedding Virtual Impedance as Current Limitation Algorithm. https://app.cochat.ai/papers/10.1109/jestpe.2019.2959085
- The paper
- Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020). Critical Clearing Time Determination and Enhancement of Grid-Forming Converters Embedding Virtual Impedance as Current Limitation Algorithm. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2019.2959085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.