The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Transient Stability Analysis and Control Design of Droop-Controlled Voltage Source Converters Considering Current Limitation
Abstract
In the modern power grid, distributed generators are widely connected to the grid via voltage source converters (VSCs). Analyzing the transient stability of VSCs under large disturbances is useful for maintaining the security of the grid. However, this topic is very little studied. In this paper, the transient stability behavior of the droop-controlled VSC is theoretically explained. In particular, it is shown that transient instability can occur to the droop-controlled VSC when its current is saturated under large disturbances. In addition, the dynamics of the VSC under voltage sags that could incur instability problem is elaborately studied to consider special non-fault disturbances. To deal with this instability problem, a stability enhanced P-f droop control is proposed. Simulations and hardware-in-the-loop experiments verify the validity of the transient stability analysis and the effectiveness of the proposed control scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Cited by
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Transient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546
Metadata
- Authors
- Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-01
- Volume
- 10
- Issue
- 1
- Pages
- 578-591
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2750703600
- Cited by
- 602
- References
- 34
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transient Stability Analysis and Control Design of Droop-Controlled Voltage Source Converters Considering Current Limitation. https://app.cochat.ai/papers/10.1109/tsg.2017.2749259
- The paper
- Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019). Transient Stability Analysis and Control Design of Droop-Controlled Voltage Source Converters Considering Current Limitation. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2017.2749259
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.