Low Stress Cycle Effect in IGBT Power Module Die-Attach Lifetime Modeling
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Operational management for reliability of power electronic converters requires sensitive condition monitoring and accurate lifetime modeling. This study adds to the second aspect by examining the effect of cyclic junction temperature variations ΔTjof low amplitude in different stages of the power module ageing process. It is found that such relatively minor stress cycles, which happen frequently during normal operation, may not be able to directly initiate a crack but can contribute to the development of damage due to stress concentration. This agrees with the observation that the ageing process tends to accelerate toward the end of life. This study investigates the dependence of the ageing effect on the amplitude of ΔTj, the mean junction temperature T,,,, and the present health condition of the module, and proposes a lifetime model focusing on die-attach solder fatigue. It is assumed that the future-ageing process is independent of the operational history that has led to the current state of health. The model is intended for operational management of converter systems that are subjected to frequent low ΔTjstress cycles and are supposed to be in service reliably for a long time with a slow ageing process. Experimental results validate the model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 3×
“Coffin–Manson–Arrhenius model to account for the different values of ΔTj and Tm [9], [19].”
BackgroundSelf-citationSelected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039
Cited by
A Digital Twin Based Estimation Method for Health Indicators of DC–DC Converters
Peng, Y., Zhao, S., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009600 · Cited by 305
Hanif, A., Yu, Y., DeVoto, D., & Khan, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2860587 · Cited by 272
Overview of Real-Time Lifetime Prediction and Extension for SiC Power Converters
Ni, Z., Lyu, X., Yadav, O. P., Singh, B. N., Zheng, S., & Cao, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2962503 · Cited by 261
Power Electronics Reliability: State of the Art and Outlook
Wang, H., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3037161 · Cited by 218
Failure and Reliability Analysis of a SiC Power Module Based on Stress Comparison to a Si Device
Hu, B., Ortiz Gonzalez, J., Ran, L., Ren, H., Zeng, Z., Lai, W., Gao, B., Alatise, O., Lu, H., Bailey, C., et al. (2017) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2017.2766692 · Cited by 202
Self-citation
Metadata
- Authors
- Lai, W., Chen, M., Ran, L., Alatise, O., Xu, S., & Mawby, P.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-09
- Volume
- 31
- Issue
- 9
- Pages
- 6575-6585
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2197739317
- Cited by
- 134
- References
- 2
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.