Reliable Modular Multilevel Converter Fault Detection With Redundant Voltage Sensor
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper presents a fault-tolerant configuration for the modular multilevel converter (MMC). The procedure is able to detect faults in voltage sensors and semiconductor switching devices, and it can reconfigure the system so that it can keep on operating. Both switch and sensor faults can be detected by comparing the output voltage of a set of submodules (SMs), which is measured by a so-called supervisory sensor, with two calculated reference voltages. Faults in the supervisory sensors are also considered. Sensor faults are overcome by using a measuring technique based on estimates that are periodically updated with the voltage measurements of the supervisory sensors. Additional SMs are included in the arms so that the MMC can bypass a faulty SM and continue operating without affecting the output voltage of the phase-leg. Experimental results obtained from a low-power MMC prototype are presented in order to demonstrate the effectiveness of the proposed techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“The harmonic components can be eliminated [12] or controlled for further reduction of capacitor voltage ripples [13], [14].”
BackgroundCircuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 1×
“Among the multilevel converter topologies, the modular multilevel converter (MMC) has become the most attractive topology [3]–[7] for high-voltage direct-current (HVDC) transmission systems [8], [9] and flexible alternating current transmission systems [10].”
BackgroundDesign and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Pou, J., Ceballos, S., Konstantinou, G., Agelidis, V. G., Picas, R., & Zaragoza, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336608 · Cited by 406 · cited 2×
“A circulating current controller [14] is implemented to regulate the internal dynamics of the converter as well as to reduce capacitor voltage ripples.”
BackgroundSelf-citationReliability Calculation of Multilevel Converters: Theory and Applications
Richardeau, F., & Pham, T. T. L. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2211315 · Cited by 212
Active Redundant Submodule Configuration in Modular Multilevel Converters
Konstantinou, G., Pou, J., Ceballos, S., & Agelidis, V. G. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2264950 · Cited by 152 · cited 2×
“Since the technique of “active” redundant SMs [21] is used, the system can maintain its performance without using the faulty SM anymore.”
BackgroundMethodSelf-citationNew Measuring Technique for Reducing the Number of Voltage Sensors in Modular Multilevel Converters
Picas, R., Zaragoza, J., Pou, J., Ceballos, S., & Balcells, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2412658 · Cited by 62
Self-citation
Cited by
Hong, J., Wang, Z., & Yao, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113381 · Cited by 378
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“The proposed measurement technique can also be used to detect submodule failures, including both, open- and shortcircuit semiconductor faults [132].”
MethodSelf-citationReliability and Cost based Redundancy Design for Modular Multilevel Converter
Tu, P., Yang, S., & Wang, P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793263 · Cited by 199
“plement redundant designs, which include cell overrating [17] and backup cells [8], [10], [18]–[20].”
BackgroundOpen-Circuit IGBT Fault Detection and Location Isolation for Cascaded Multilevel Converters
Lamb, J., & Mirafzal, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674629 · Cited by 170
“, [12], [27], the fault location must be pinpointed [9].”
BackgroundMethodInfluentialZhou, D., Yang, S., & Tang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2796584 · Cited by 143
Metadata
- Authors
- Picas, R., Zaragoza, J., Pou, J., & Ceballos, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-01
- Volume
- 32
- Issue
- 1
- Pages
- 39-51
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2343375316
- Cited by
- 134
- References
- 7
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.