Active Redundant Submodule Configuration in Modular Multilevel Converters
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The modular multilevel converter (MMC) is based on the cascaded connection of identical submodules (SMs) enabling additional redundancies. This paper proposes the configuration of the MMC topology with redundant SMs and demonstrates the effects of active redundancies. The proposed configuration decreases the switching frequency per SM while reducing the SM capacitor voltage ripples. An analytical model for determining the SM capacitor voltage ripple and voltage dynamics is derived. The results from the analytical model are compared with the switching model for a 21-level MMC with five redundant (25 in total) SMs per arm. Experimental results based on a single-phase laboratory prototype with five SMs per arm and a single redundant cell further illustrate the operation and verify the derived mathematical model and simulation results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“and lower switching frequency, resulting in more efficient operation of the overall conversion system [3].”
BackgroundSelf-citationAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 2×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundVSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“Multilevel converters are particularly suitable for high-power applications, such as high-voltage direct current (HVDC) transmission [1], static synchronous compensators”
BackgroundSelf-citationControl and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“The MMC is a member of the broad family of cascade multilevel converters [17] and features significant ad-”
BackgroundModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Gnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“as steady-state [24] and dynamic [25] analysis of the converter”
Background
Cited by
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
“3) Reliability: The MMC, due to its structural modularity, can improve fault tolerance by augmenting redundant SMs in its structure [12], [68], thereby, increasing its reliability.”
BackgroundSurvey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“always operate in normal/healthy conditions; therefore, the average switching frequency per module can be reduced and the task of voltage balancing can be simplified as detailed in [51].”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
“There are two types of the SM reserve mode for the MMC: the cold reserve mode and the spinning reserve mode [39], [40].”
MethodModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
Self-citationTowards Long Lifetime Battery: AI-Based Manufacturing and Management
Liu, K., Wei, Z., Zhang, C., Shang, Y., Teodorescu, R., & Han, Q.-L. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.105599 · Cited by 302
“Diverse reconfigurable topologies with 1~6 switches per cell have been reported in the existing literature [52].”
Background
Metadata
- Authors
- Konstantinou, G., Pou, J., Ceballos, S., & Agelidis, V. G.
- Affiliations
- UNSW Sydney (AU)
- Tecnalia (ES)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2013-10
- Volume
- 28
- Issue
- 4
- Pages
- 2333-2341
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W1995673130
- Cited by
- 152
- References
- 30
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 7 · 2023: 14 · 2022: 8 · 2021: 11 · 2020: 14 · 2019: 15 · 2018: 16 · 2017: 11 · 2016: 18 · 2015: 16 · 2014: 14
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (acceptedVersion, other-oa)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, active redundancy, switching frequency reduction, voltage dynamics, analytical model, single-phase converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Redundant Submodule Configuration in Modular Multilevel Converters. https://app.cochat.ai/papers/10.1109/tpwrd.2013.2264950
- The paper
- Konstantinou, G., Pou, J., Ceballos, S., & Agelidis, V. G. (2013). Active Redundant Submodule Configuration in Modular Multilevel Converters. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2013.2264950
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.