A Three-Phase Hybrid Cascaded Modular Multilevel Inverter for Renewable Energy Environment
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
This paper presents a three-phase hybrid cascaded modular multilevel inverter topology which is derived from the proposed modified H-bridge module. This topology results in the reduction of number of power switches, losses, installation area, voltage stress and converter cost. For renewable energy environment such as photovoltaic (PV) connected to the microgrid system, it enables the tranformerless operation and enhances the power quality. This multilevel inverter is an effective and efficient power electronic interface strategy for renewable energy systems. The basic operation of single module and the proposed cascaded hybrid topology is explained. The ability to operate in both symmetrical and asymmetrical modes is analyzed. The comparative analysis is done with classical cascaded H-bridge and flying capacitor multilevel inverters. The nearest level control method is employed to generate the gating signals for the power semiconductor switches. To verify the applicability and performance of the proposed structure in PV renewable energy environment, simulation results are carried out by MATLAB/Simulink under both steady-state and dynamic conditions. Experimental results are presented to validate the simulation results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comprehensive Approach to Modeling and Simulation of Photovoltaic Arrays
Villalva, M. G., Gazoli, J. R., & Filho, E. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2013862 · Cited by 4,390 · cited 1×
“8 [32].”
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“The different topology presented in the literature as multilevel converters [3], [4] possesses the number of characteristics, giving their clear advantages over bilevel converters.”
Optimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002 · cited 1×
“Because of simplicity and efficient tracking, P&O is implemented [34]–[44].”
A Comparative Study on Maximum Power Point Tracking Techniques for Photovoltaic Power Systems
Subudhi, B., & Pradhan, R. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2202294 · Cited by 1,867
Multi-level conversion: high voltage choppers and voltage-source inverters
Meynard, T. A., & Foch, H. (2003) · PESC `92 Record. 23rd Annual IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1992.254717 · Cited by 1,455 · cited 2×
“Parameter Symmetrical [7] Asymmetrical [30] FC [2] Symmetrical (P) Asymmetrical”
Abu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337 · cited 1×
“The different topology presented in the literature as multilevel converters [3], [4] possesses the number of characteristics, giving their clear advantages over bilevel converters.”
Multilevel Inverter Topologies With Reduced Device Count: A Review
Gupta, K. K., Ranjan, A., Bhatnagar, P., Sahu, L. K., & Jain, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2405012 · Cited by 1,193 · cited 1×
“Single-phase and three-phase MLI topologies are reported in [11] and [12] focusing on less switch count.”
Li, Q., & Wolfs, P. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.920883 · Cited by 1,153 · cited 1×
“Various MLI topologies for renewable energy applications are listed in [8]–[10].”
High-Performance Adaptive Perturb and Observe MPPT Technique for Photovoltaic-Based Microgrids
Abdelsalam, A. K., Massoud, A. M., Ahmed, S., & Enjeti, P. N. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106221 · Cited by 879
Multilevel Inverter Topologies for Stand-Alone PV Systems
Daher, S., Schmid, J., & Antunes, F. L. M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922601 · Cited by 641 · cited 1×
“Various MLI topologies for renewable energy applications are listed in [8]–[10].”
Single-Phase Seven-Level Grid-Connected Inverter for Photovoltaic System
Rahim, N. A., Chaniago, K., & Selvaraj, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064278 · Cited by 438
Meshram, P. M., & Borghate, V. B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2317705 · Cited by 405 · cited 1×
“The NLC or round method is a low switching frequency control technique [48].”
Self-citationA hybrid multilevel inverter topology for drive applications
Manjrekar, M. D., & Lipo, T. A. (2002) · APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1998.653825 · Cited by 354
Classification and Comparative Evaluation of PV Panel-Integrated DC–DC Converter Concepts
Kasper, M., Bortis, D., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273399 · Cited by 332 · cited 1×
“Because of simplicity and efficient tracking, P&O is implemented [34]–[44].”
Brunton, S. L., Rowley, C. W., Kulkarni, S. R., & Clarkson, C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049747 · Cited by 328
Islam, M. R., Guo, Y., & Zhu, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2290313 · Cited by 301 · cited 1×
“Three-phase topologies are developed focusing on reducing the complexity issue [18], [19].”
Line–Line Fault Analysis and Protection Challenges in Solar Photovoltaic Arrays
Zhao, Y., De Palma, J.-F., Mosesian, J., Lyons, R., & Lehman, B. (2013) · Industrial Electronics, IEEE Transactions on · doi:10.1109/tie.2012.2205355 · Cited by 300 · cited 1×
“To discuss the impact of removing a PV panel for the purpose of maintenance or failure due to faults [49] on the behavior of overall inverter, the PV RES connected to the proposed ninelevel HCM MLI for single phase is shown in Fig.”
Photovoltaic DC-Building-Module-Based BIPV System—Concept and Design Considerations
Liu, B., Duan, S., & Cai, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2085087 · Cited by 278
Lyden, S., & Haque, M. E. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2468592 · Cited by 248
Partial Shading Detection and Smooth Maximum Power Point Tracking of PV Arrays Under PSC
Ghasemi, M. A., Foroushani, H. M., & Parniani, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2504515 · Cited by 217
Babaei, E., Farhadi Kangarlu, M., & Sabahi, M. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0057 · Cited by 212 · cited 1×
“In order to reduce one source, two capacitors and one dc source are employed [29].”
A Nine-Level Grid-Connected Converter Topology for Single-Phase Transformerless PV Systems
Buticchi, G., Barater, D., Lorenzani, E., Concari, C., & Franceschini, G. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2286562 · Cited by 204
Symmetrical Hybrid Multilevel DC–AC Converters With Reduced Number of Insulated DC Supplies
Ruiz-Caballero, D., Astudillo, R. R., Mussa, S. A., & Heldwein, M. L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036636 · Cited by 160 · cited 1×
“The hybrid three-phase symmetrical [22], [23] and asymmetrical [24]–[26] configurations are developed.”
Three-Phase Cascaded Multilevel Inverter Using Power Cells With Two Inverter Legs in Series
Waltrich, G., & Barbi, I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043040 · Cited by 159 · cited 1×
“Three-phase topologies are developed focusing on reducing the complexity issue [18], [19].”
Impedance Matching in Photovoltaic Systems Using Cascaded Boost Converters and Sliding-Mode Control
Haroun, R., Aroudi, A. E., Cid‐Pastor, A., García, G., Olalla, C., & Martinez-Salamero, L. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2339134 · Cited by 157
Improved Design of Sliding-Mode Controllers Based on the Requirements of MPPT Techniques
Montoya, D. G., Ramos‐Paja, C. A., & Giral, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2397831 · Cited by 154
A Solar Power Generation System With a Seven-Level Inverter
Wu, J., & Chou, C.-W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2279880 · Cited by 148
Novel Vector Control Method for Three-Stage Hybrid Cascaded Multilevel Inverter
Mekhilef, S., & Kadir, M. N. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049716 · Cited by 137
Maximum Power Point Tracking Using Model Reference Adaptive Control
Khanna, R., Zhang, Q., Stanchina, W. E., Reed, G. F., & Mao, Z. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2263154 · Cited by 135
Simplified Space Vector Modulation Techniques for Multilevel Inverters
Ahmed, I., Borghate, V. B., Matsa, A., Meshram, P. M., Suryawanshi, H. M., & Chaudhari, M. A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2520078 · Cited by 132 · cited 1×
“The application of SVM for MLIs is limited due to its complexity with an increase in the number of levels despite the efforts have been made to reduce it [45], [46].”
Self-citationSharma, P., & Agarwal, V. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2285075 · Cited by 118 · cited 1×
“The partial shading causes the fluctuations in irradiance [50]–[52].”
Simplified space vector modulation technique for seven‐level cascaded H‐bridge inverter
Ahmed, I., & Borghate, V. B. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0135 · Cited by 98 · cited 1×
“The application of SVM for MLIs is limited due to its complexity with an increase in the number of levels despite the efforts have been made to reduce it [45], [46].”
Self-citationCharge balance control methods for asymmetrical cascade multilevel converters
Babaei, E., & Hosseini, S. H. (2007) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems12746.2007.4412143 · Cited by 88
Chen, C., Liao, C.-Y., Chen, K.-H., & Chen, Y.-M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2367594 · Cited by 86
Global Maximum Power Point Tracking of Flexible Photovoltaic Modules
Konstantopoulos, C., & Koutroulis, E. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2275947 · Cited by 76
A Function-Based Maximum Power Point Tracking Method for Photovoltaic Systems
Tousi, S. M. R., Moradi, M. H., Basir, N. S., & Nemati, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2426652 · Cited by 65
Multilevel Converters in Renewable Energy Systems
Nami, A., & Zare, F. (2009) · InTech eBooks · doi:10.5772/7365 · Cited by 18
Cited by
Bana, P. R., Panda, K. P., Naayagi, R. T., Siano, P., & Panda, G. (2019) · IEEE Access · doi:10.1109/access.2019.2913447 · Cited by 361
Prabaharan, N., & Palanisamy, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.121 · Cited by 302
Salem, A., Van Khang, H., Robbersmyr, K. G., Norambuena, M., & Rodriguez, J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011908 · Cited by 285
Rana, R. A., Patel, S. A., Muthusamy, A., Lee, C. W., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics8111329 · Cited by 102
Metadata
- Authors
- Karasani, R. R., Borghate, V. B., Meshram, P. M., Suryawanshi, H. M., & Sabyasachi, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-02
- Volume
- 32
- Issue
- 2
- Pages
- 1070-1087
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2324522970
- Cited by
- 195
- References
- 37
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.