Current Similarity Analysis-Based Open-Circuit Fault Diagnosis for Two-Level Three-Phase PWM Rectifier
The DOI matches its Crossref record; 36 of the 39 references it cites were found in a registry or an index.
Abstract
This paper proposed a novel single and multiple transistors open-circuit fault diagnosis method for two-level three-phase pulse-width modulating rectifier based on topology symmetry analysis in healthy and faulty conditions. First, similarity measurements between any two phase current linklists contained samples in a period after reconstruction and shape analysis, such as Euclidean distance, correlation coefficient, and cosine angle, are used to describe the symmetry of topology and divide the faults into three classes, then two extra features are extracted to locate the fault to broken leg and transistors, respectively. The proposed diagnostic method is robust, low cost, and easy to insert to the existed control system. The effectiveness and merit were evaluated by experimental results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [270]
In the citing paper
“Rectifier transistors failures lead to voltage asymmetry on capacitors, which enables simple detection of a damaged transistor on the basis of additional information about phase polarization or switching state configuration defined by duty cycle factors [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [270]
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135 · cited 1×
“As a result, the system will be shut down by the subsequent faults and needs higher repairing cost [11], [12].”
BackgroundCondition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019 · cited 1×
“Recent surveys show that the failure rate of semiconductor power device reduces, as the most fragile component, their failure rate is 31%, which follows by “capacitors” and “gate drives” [3]–[5].”
BackgroundCondition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“Recent surveys show that the failure rate of semiconductor power device reduces, as the most fragile component, their failure rate is 31%, which follows by “capacitors” and “gate drives” [3]–[5].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
On the Need for Time Series Data Mining Benchmarks: A Survey and Empirical Demonstration
Keogh, E., & Kasetty, S. (2003) · Data Mining and Knowledge Discovery · doi:10.1023/a:1024988512476 · Cited by 861
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620 · cited 1×
“Power converters are complex devices that are often exposed to high stresses, being therefore very prone to suffer critical failures [2].”
BackgroundFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“Fair robustness, fast detection time, and effective location can be achieved in some voltage-based methods [13]–[15] at the cost of extra voltage sensors or electrical circuits.”
BackgroundZidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335 · cited 1×
“However, open circuit does not immediately cause the system shutdown and can remain undetected for an extended period of time [10], this can lead to overstress on the healthy switches and in turn cause second failures in other components, as well as lead to a ripple outputs.”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329 · cited 1×
“Lots of currentsbased methods are proposed in [8] and [28] for multilevel converter.”
Method
Research works printed but not linked: 2
- 10.1109/tie.2015.2417501 · DOI · Paper page
- doki?, 2015, Power Electronics-converters and Regulators
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[270] Topology symmetry analysis based on signal statistical parameters”
BackgroundMethodJlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Current similarity analysis for open-circuit fault diagnosis in the three-phase PWM rectifier is presented in [15].”
BackgroundYang, C., Gui, W., Chen, Z., Zhang, J., Peng, T., Yang, C., Karimi, H. R., & Ding, S. X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2924487 · Cited by 122
Open-circuit fault diagnosis of power rectifier using sparse autoencoder based deep neural network
Xu, L., Cao, M., Song, B., Zhang, J., Liu, Y., & Alsaadi, F. E. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.05.040 · Cited by 84
Xie, D., & Ge, X. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2873533 · Cited by 82
“methods in [7]–[11] can directly use signals from the control system for fault analysis without additional hardware, such as”
MethodZhou, D., Li, X., & Tang, Y. K. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2750766 · Cited by 67
Ahmed, H. M., Jlassi, I., Cardoso, A. J. M., & Bentaallah, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3132236 · Cited by 59
“analysis for a three-phase rectifier was presented in [23] with the capability to detect multiple faults.”
BackgroundShi, T., He, Y., Wang, T., Jin, T., Li, B., & Deng, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2905296 · Cited by 58
“vided a feasible solution by analyzing the waveform features of currents [21]–[23].”
BackgroundZhou, D., & Tang, Y. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2888879 · Cited by 56
“A current similarity analysisbased diagnostic method was proposed in [16], but the computational burden of the similarity measurement was too heavy to”
MethodZhao, X., & Niu, S. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2847292 · Cited by 53
“2(a) to realize power factor correction for AC to DC energy conversion, which results in increased cost burden and reliability reduction [6–7].”
BackgroundXu, S., Tao, S., Zheng, W. X., Chai, Y., Ma, M., & Ding, L. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3062683 · Cited by 48
“Other methods use current similarity analysis and current distortion analysis to diagnose open-circuit faults in three-phase PWM rectifiers [30], [31].”
MethodFault Detection and Identification Scheme for Dual-Inverter Fed OEWIM Drive
Yang, S., Sun, X., Ma, M., Zhang, X., & Chang, L. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2922924 · Cited by 46
“In [3], topology symmetry analysis in healthy and faulty states was relied on to achieve the diagnosis.”
BackgroundMethodWu, F., Hao, Y., Zhao, J., & Liu, Y. (2017) · Microelectronics Reliability · doi:10.1016/j.microrel.2017.05.036 · Cited by 42
Self-citationZhang, W., & He, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151731 · Cited by 43
“For phase currentbased methods, the normalized average value [11], radius, angle [12], root-mean-square [13], Park’s vector [14], zerocrossing characteristics [15]-[18], similarity features [19]of the phase current can be utilized for OC fault diagnosis.”
MethodAdaptive Fast Fault Location for Open-Switch Faults of Voltage Source Inverter
Yin, H., Chen, Y., Chen, Z., & Li, M. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3093643 · Cited by 37
Zhang, W., He, Y., & Chen, J. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3230091 · Cited by 36
“root-mean-square values [13], the radius of the current pattern [14], current similarity [15], and zero-crossing (ZC) characteristics [16], [17], [18], [19] of the phase current can be analyzed di-”
BackgroundMethodZhang, W., He, Y., Wang, C., Chen, M., & Sui, C. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3096851 · Cited by 35
Zhang, P., Chen, R., Xu, X., Yang, L., & Mengyu, R. (2023) · Measurement · doi:10.1016/j.measurement.2023.113711 · Cited by 35
An Online Metric Learning-Based Open-Switch and Current Sensor Fault Diagnosis for MSPMSM Systems
Du, Y., Li, C., & Zheng, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3265936 · Cited by 32
“Based on metric learning, Euclidean distance (ED) and improved cosine distance are used to diagnose PMSM drives [31] and multilevel converters [32], respectively.”
MethodLi, K., Cheng, S., Yu, T., Wu, X., Xiang, C., & Akin, B. (2020) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2020.2987935 · Cited by 31
“A fault diagnostic method for a three-phase pulse width modulation (PWM) rectifier based on current similarity analysis was presented in [27], which can achieve 21 types of fault diagnoses.”
MethodDong, M., Dong, H., Wang, L., Yang, J., Li, L., & Wang, Y. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751508 · Cited by 30
“In [5] and [6], by using the amplitude and phase of the normalized average current vector, a current-based fault detection method is used to check the OCFs of inverters.”
MethodShi, T., He, Y., Deng, F., Jin, T., Wang, T., & Shi, L. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0438 · Cited by 27
Wang, W., Kou, L., Yuan, Q., Zhou, J., Liu, C., & Cai, G.-W. (2020) · IEEE Access · doi:10.1109/access.2020.3043796 · Cited by 27
“References [10], [15] and [31] rely on the specific thresholds, the performance of fault diagnosis is easily affected by thresholds, and the set methods are all different.”
MethodCurrent behavior-based open-switch fault on-line diagnosis of inverters in PMSM drive systems
Zhang, Y. (2022) · Measurement · doi:10.1016/j.measurement.2022.111810 · Cited by 24
Domain Adversarial Neural Network for Mapping Mineral Prospectivity
Lin, Q., & Zuo, R. (2024) · Mathematical Geosciences · doi:10.1007/s11004-024-10164-3 · Cited by 22
Zhang, W., & He, Y. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3194150 · Cited by 17
“crossing characteristics [13]–[19], and similarity features [20] can be used for OC fault diagnosis.”
BackgroundReal-Time Open-Circuit Fault Diagnosis Method for T-Type Rectifiers Based on Median Current Analysis
Wu, Z., Zhao, J., Luo, H., & Liu, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3265188 · Cited by 17
“According to the energy transformation form, there are diagnostic methods for rectifiers [14], [15], inverters [16], [17], and bidirectional converters [18], [19].”
MethodSelf-citationAn Overview on Fault Management for Electric Vehicle Onboard Chargers
Gaona-Cárdenas, L.-F., Vázquez, N., Ruiz‐Martinez, O. F., Espinosa-Calderón, A., Gutiérrez, A. I. B., & Rodríguez, M. (2022) · Electronics · doi:10.3390/electronics11071107 · Cited by 16
“[43] 40 Medium Current control No 140 VAC (3φ) 230-280 VDC 80–85% No No 0 3φ 2-Level”
BackgroundAn Open-Circuit Fault Detection Method of PMSM Fed by Dual Inverter With High Robustness
Jiang, C., Liu, H., Wheeler, P. W., Wu, F., & Huo, J. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3263160 · Cited by 17
Self-citationANN design of multiple open‐switch fault diagnosis for three‐phase PWM converters
Kim, W., & Kim, S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0795 · Cited by 16
“However, the behaviour of the open-switch fault in the converter is different from that of the inverter, since there is a possibility of the rectification of input voltages through anti-parallel diodes [16–18].”
BackgroundMethodSui, C., He, Y., & Chen, M. (2019) · IEEE Access · doi:10.1109/access.2019.2963117 · Cited by 17
“Based on symmetry analysis in healthy and faulty conditions, a fault detection and location method was proposed in [27].”
MethodYang, H., Zhou, Y., & Zhao, J. (2020) · Journal of Power Electronics · doi:10.1007/s43236-020-00043-5 · Cited by 16
Self-citationVoltage and Current Sensor Fault Diagnosis Method for Traction Rectifier in High-Speed Trains
Yu, Y., Song, Y., Tao, H., & Hu, J. (2024) · Electronics · doi:10.3390/electronics13010197 · Cited by 15
Du, B., He, Y., & Zhang, Y. (2020) · Electronics · doi:10.3390/electronics9101570 · Cited by 15
“, lower harmonic distortion of line current, stabilization, and regulation of the DC-link monitoring signal [2].”
BackgroundWang, S., Lei, Y., Lü, N., Li, X., & Yang, B. (2023) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-022-0736-9 · Cited by 15
“As a result, multi-sensor fusion is preferred due to the enrichment of different sensor information to achieve high diagnosis accuracy for fault recognition and fault localization [18,19].”
BackgroundOpen Circuit Fault Diagnosis and Fault Tolerance of Three-Phase Bridgeless Rectifier
Cheng, H. L., Chen, W., Wang, C., & Deng, J. (2018) · Electronics · doi:10.3390/electronics7110291 · Cited by 15
An Open-Circuit Fault Diagnosis Method for Four-Wire T-Type Three-Level Rectifier
Wu, Z., Sun, J., Song, Y., & Zhao, J. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3196667 · Cited by 13
“Recently, many research studies have been published on open-circuit fault diagnosis in two-level three-phase converters [8], [9], [10], [11].”
BackgroundSelf-citationAbari, I., Hamouda, M., Slama, J. B. H., & Al‐Haddad, K. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591826 · Cited by 12
“It was mentioned in [3] that about 38% of the faults are generated due to power devices breakdowns.”
BackgroundInverter Open Circuit fault diagnosis method based on ISMO for Improved Efficiency
Han, S., Zhao, G., Gao, J., & Jia, J. (2024) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2024.109650 · Cited by 12
Zhou, D., & Tang, Y. K. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507836 · Cited by 11
Sharan, B., & Jain, T. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0510 · Cited by 11
Sun, Y., Chen, J., Qiu, R., & Li, C. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3338708 · Cited by 15
“Current-driven includes the direct use of current signals in the control system for fault analysis [15], [16] without additional hardware circuits.”
BackgroundIGBT open-circuit fault detection for voltage source inverters using DC bus magnetic field signal
Vu, H., & Yahoui, H. (2021) · Electrical Engineering · doi:10.1007/s00202-020-01161-w · Cited by 10
A Review of Symmetry-Based Open-Circuit Fault Diagnostic Methods for Power Converters
Zhou, Y., Zhao, J., & Wu, Z. (2024) · Symmetry · doi:10.3390/sym16020204 · Cited by 11
“Based on Equation (1), The ED between two current time series at instant t is where In [26], based on zero-crossing-detection, the phase current of inverters were reconstructed and the ED between reconstructed signals under different health conditions was calculated.”
BackgroundMethodInfluentialSelf-citationStudy of Constant DC-Voltage Control for VIENNA Rectifier Under No-Load Condition
Song, W., Yang, Y., Du, M., & Wheeler, P. W. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3469173 · Cited by 9
“Pulsewidth-modulated (PWM) rectifiers including two-and three-level unidirectional PWM rectifiers have advantages over diode bridge rectifiers because of low input current total harmonic distortion (THD) and controllable power factor (PF) [1], [2], [3].”
Zhang, J., Peng, T., Yang, C., Chen, Z., Tao, H., & Yang, C. (2019) · Electronics · doi:10.3390/electronics8090992 · Cited by 9
Gao, Z., Chen, T., & Zhang, C. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.10.015 · Cited by 7
Sharan, B., & Jain, T. (2018) · International Conference on Control, Automation, Robotics and Vision (ICARCV) · doi:10.1109/icarcv.2018.8581145 · Cited by 7
“Current similarity analysis based open circuited fault diagnosis for one or two switches is presented in [12].”
BackgroundGuo, F., Yang, T., Bozhko, S. V., & Wheeler, P. W. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864839 · Cited by 7
“In [9], diagnosis method strictly depends on symmetrical circuit.”
MethodIGBT open-circuit fault diagnosis based on the current prediction in the line-side AC/DC converter
Sobański, P., & Orłowska-Kowalska, T. (2017) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2017.7913068 · Cited by 5
“Nevertheless, the effective fault diagnosis can be obtained calculating Euclidean distance between the estimated and measured diagnostic signals or utilizing a statistical analysis such as a correlation calculation [12, 13].”
MethodAdaptive Fault Detection for Grid-Forming Inverters
Intriago, G., & Zhang, Y. (2024) · IEEE Access · doi:10.1109/access.2024.3389073 · Cited by 4
“Signal processing based methods generally sample voltage, current, and auxiliary signals without an accurate system model [8], [9], [10], [11], [12].”
MethodChen, Z., Bai, B., Chen, D., & Chai, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2809588 · Cited by 4
“9 shows the hybrid power supply schematic diagram [32].”
BackgroundPillai, H. K. R., Mayadevi, N., Mini, V. P., & Sathyabhama, S. P. (2022) · International Journal of Engineering and Technology Innovation · doi:10.46604/ijeti.2023.10005 · Cited by 4
“Neural networks [13] 20 ms High Yes Yes Yes Yes High High High Complex Load current similarity analysis [28] 5 ms High Yes Yes No No Medium Less Low Complex Modified Park’s vector method [29] > 2 cycles Low Yes No No No High Low Low Simple Normalized DC current [29] Less than one cycle Low Yes No No No Low Low Low Sim…”
Liu, B., Shi, T., Yan, Y., Zhang, G., & Xia, C. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3563506 · Cited by 4
“The current similarity analysis-based method is proposed to detect 21 open-circuit faults in [26].”
A Similarity-Based Robust Open-Circuit Fault Diagnosis Method for Dual Pulse Rectifiers
Deng, Q., Zhao, S., Lin, C., Gou, B., Xie, D., Ge, X., Feng, X., & Wang, H. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3397049 · Cited by 4
“…threshold setting for fast speed of fault detection and high false alarm immunity, which have been verified effectively in the applications of a two-level three-phase rectifier in [11], modular multilevel converters in [12], andmulti-sectorpermanentmagnetsynchronousmotorsystemsin[13],for example.”
BackgroundResearch on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Zhang, B., Ping, S., Long, Y., Jiao, Y., & Wu, B. (2022) · Archives of Electrical Engineering · doi:10.24425/aee.2022.140724 · Cited by 3
“In reference [14], fuzzy control was adopted, and in references [15–17], the method of an adjacent long vector and synthetic medium vector was adopted, which has a good balance effect.”
MethodZou, Z. (2024) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2024.00005 · Cited by 5
“After years of development, the related research on switch fault diagnosis technology [4] - [8] has matured comparatively, but the fault-tolerant control after a switch fault is limited by the converter topology and has not been effectively solved.”
Multiple open-circuit fault diagnosis of three-phase rectifier based on current data reconstruction
Tian, L., Hu, B., Cao, X., Zhang, H., & Yu, Q. (2022) · International Journal of Electronics · doi:10.1080/00207217.2022.2068669 · Cited by 3
“A method based on topology symmetry for rectifiers’ multiple open-circuit faults is published in (Wu & Zhao, 2016).”
MethodSong, Y., & Zhao, J. (2022) · Chinese Control Conference (CCC) · doi:10.23919/ccc55666.2022.9902395 · Cited by 4
“The former extracts fault features from current information, including current vector [2], average current [3], current reference error [4], near-zero current [5], and current similarity [6].”
BackgroundSelf-citationOnline Fault Detection of Open-Circuit Faults in a DTP-PMSM Using Double DQ Current Prediction
Geng, Q., Du, W., Jin, X., Zhang, G., & Zhou, Z. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15050204 · Cited by 3
“Current signals, as essential monitoring indicators in motor control systems, are often selected for open-circuit fault diagnosis using methods such as phase current average value [9], radius [10], angle [11], Park vector [12], zero crossing (ZC) feature [13,14], and similarity feature [15].”
MethodLiu, C., Yang, Z., Yang, Y., Liu, H., & Yu, Y. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3420373 · Cited by 3
“Wu and Zhao [11] proposed an open-switch fault diagnosis method based on the topology symmetry analysis in healthy and faulty conditions.”
BackgroundMethodInfluentialIGBT open-circuit fault diagnosis based on the voltage estimation in the line-side AC/DC converter
Sobański, P., & Orłowska-Kowalska, T. (2017) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2017.8001527 · Cited by 3
“From the literature survey it is known that all of the mentioned transistor fault diagnostic methods effectiveness can be improved using statistical approaches such as correlation calculation [11, 12].”
BackgroundKovačević, H., Drevenšek, D., Ban, Ž., Svečko, R., & Milanovič, M. (2022) · Sensors · doi:10.3390/s22062249 · Cited by 2
A Diagnosis Method of Inverter Anomalies under DoS Attack Based on Interval Sliding Mode Observer
Li, J., & Zhang, Y. M. (2022) · IEEE International Conference on Industrial Cyber-Physical Systems (ICPS) · doi:10.1109/icps51978.2022.9816944 · Cited by 2
Fault diagnosis of power electronic circuits using optimized BP neural networks
Jiang, D., Huang, S., & Guo, J. (2024) · MATEC Web of Conferences · doi:10.1051/matecconf/202439900016 · Cited by 2
TSSA-Based Multifault Diagnosis Algorithm for Microgrid Inverter
Huang, Z., Zhang, A., Shao, W., Hu, K., & Xie, J. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3485722 · Cited by 2
“In recent years, switches open-circuit fault diagnosis has been extensively studied [14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26].”
InfluentialZhou, Y., Wu, F., & Zhao, J. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367932 · Cited by 2
“Taking the implementation cost into consideration, most of the open-circuit faults diagnosis methods are softwarebased due to no extra electronic circuit and sensors are needed [10].”
BackgroundMethodSelf-citationMultiple Open-Switch Fault Diagnosis Using ANNs for Three-Phase PWM Converters
Kim, W., & Kim, S. (2021) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems52562.2021.9634387 · Cited by 1
Fault Diagnosis of Three-phase Full-bridge Rectifier Circuit based on Deep Neural Network
Song, B., Kang, C., Xu, L., & Zhang, J. (2018) · Chinese Automation Congress · doi:10.1109/cac.2018.8623247 · Cited by 1
Sharan, B., Jain, T., & Yame, J. J. (2019) · Conference on Control and Fault-Tolerant Systems · doi:10.1109/systol.2019.8864761 · Cited by 1
“Current similarity analysis based open-circuit fault diagnosis for one or two switches is presented in [14].”
BackgroundProposed Open-Circuit Faults Detection Using Control Charts Technique
Mansour, A. S., & Amin, A. A. (2019) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon47431.2019.9008203 · Cited by 1
Li, T., Du, G., Lei, Y., & Chen, S. (2021) · Journal of Power Electronics · doi:10.1007/s43236-021-00360-3 · Cited by 1
“According to the survey, power devices account for approximately 38% of the failures [9, 10], which can be divided into short-circuit faults and open-circuit faults [11].”
BackgroundFast Open-Switch Fault Diagnosis Based on Model Reference Adaptive Theory Applied to Inverter System
Yin, H., Chen, Q., Guo, X., Qiu, X., Duan, X., & Zhao, X. (2022) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes56491.2022.10073066 · Cited by 1
“In summary, the open circuit fault diagnosis algorithm [6-24] mainly includes the above four methods, and the research gap is to shorten the fault detection time and simplify the algorithm to reduce additional costs.”
MethodFault detection and reconfiguration of the 12-pulse thyristor rectifier
Nejad, A. Z., & Dastfan, A. (2023) · Iranian Conference on Renewable Energy & Distributed Generation (ICREDG) · doi:10.1109/icredg58341.2023.10092138 · Cited by 1
“Using a switch estate estimator is one of the solutions for fault diagnosis in a 12-pulse SCR rectifier [22].”
MethodDu, Y., Wang, K., Li, C., Liu, C., & Zheng, Z. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3458990 · Cited by 1
“As can be seen from [35] and [36], L is an integer multiple of the sampling ratio; due to measurement noise, manufacturing differences in the impact of large L will make the HMD too small; the range is generally desired level of identification, the HMD is satisfied by 50%–70% lower than the HMD in…”
A Study on PWM Rectifier for Battery Charging Applications – A Review
Shwetha, G. C., & P., G. K. (2022) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.e3608.0611522
Liao, J., Huang, H., Li, X., Zhou, Z., Lai, K., Xu, J., & He, X. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567932
“The fault diagnosis of two-level three-phase pulse width modulation rectifier based on topological symmetry analysis mentioned in [8] has the advantages of high efficiency and accuracy, high reliability and simple model, but there are also some limitations, such as limited range, dependent model…”
Background$H_{i}/H_{\infty}$ Optimization Based Fault Detection for Traction Rectifier in High-Speed Train
Zhang, K., Zhong, M., Hao, S., Zhong, N., Wang, Q., & Zhang, L. (2024) · China Automation Congress (CAC) · doi:10.1109/cac63892.2024.10864966
“The mentioned factors subsequently give rise to coupling effects among physical fields such as electricity, heat, force and magnetism, which further result in faults and multi-source disturbances in the rectifier [4].”
Detection and Localization of Open-Circuit Fault in Two-Level Inverters Feeding PMSM
Misaghi, S., & Afsharirad, H. (2025) · doi:10.1109/icemd68435.2025.11441833
“In [13], three-phase current signals and the symmetry between them are utilized to detect faults in the switches.”
Multi-Fault Diagnosis of Three-Phase Four-Wire Inverter Based on Fuzzy Logic
Huang, J., Sun, Y., Fu, H., Wang, G., Yin, Z., Cui, K., & Zhang, C. (2026) · Energies · doi:10.3390/en19132953
Zhang, C., He, M., Meng, X., Liu, H., Zhou, S., & Huang, Y. (2026) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2026.117431 · Cited by 1
Metadata
- Authors
- Wu, F., & Zhao, J.
- Affiliations
- Huazhong University of Science and Technology (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-05
- Volume
- 32
- Issue
- 5
- Pages
- 3935-3945
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2474705815
- Cited by
- 82
- References
- 39
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 17 · 2023: 6 · 2022: 15 · 2021: 7 · 2020: 7 · 2019: 8 · 2018: 11 · 2017: 6
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (61273174, 61573159)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- open-circuit fault diagnosis, fault classification, shape analysis, current reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.