This paper proposed a novel single and multiple transistors open-circuit fault diagnosis method for two-level three-phase pulse-width modulating rectifier based on topology symmetry analysis in healthy and faulty conditions. First, similarity measurements between any two phase current linklists contained samples in a period after reconstruction and shape analysis, such as Euclidean distance, correlation coefficient, and cosine angle, are used to describe the symmetry of topology and divide the faults into three classes, then two extra features are extracted to locate the fault to broken leg and transistors, respectively. The proposed diagnostic method is robust, low cost, and easy to insert to the existed control system. The effectiveness and merit were evaluated by experimental results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [270]
In the citing paper
“Rectifier transistors failures lead to voltage asymmetry on capacitors, which enables simple detection of a damaged transistor on the basis of additional information about phase polarization or switching state configuration defined by duty cycle factors [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [270]
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135 · cited 1×
“As a result, the system will be shut down by the subsequent faults and needs higher repairing cost [11], [12].”
BackgroundCondition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019 · cited 1×
“Recent surveys show that the failure rate of semiconductor power device reduces, as the most fragile component, their failure rate is 31%, which follows by “capacitors” and “gate drives” [3]–[5].”
BackgroundCondition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“Recent surveys show that the failure rate of semiconductor power device reduces, as the most fragile component, their failure rate is 31%, which follows by “capacitors” and “gate drives” [3]–[5].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
On the Need for Time Series Data Mining Benchmarks: A Survey and Empirical Demonstration
Keogh, E., & Kasetty, S. (2003) · Data Mining and Knowledge Discovery · doi:10.1023/a:1024988512476 · Cited by 861
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620 · cited 1×
“Power converters are complex devices that are often exposed to high stresses, being therefore very prone to suffer critical failures [2].”
BackgroundFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“Fair robustness, fast detection time, and effective location can be achieved in some voltage-based methods [13]–[15] at the cost of extra voltage sensors or electrical circuits.”
BackgroundZidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335 · cited 1×
“However, open circuit does not immediately cause the system shutdown and can remain undetected for an extended period of time [10], this can lead to overstress on the healthy switches and in turn cause second failures in other components, as well as lead to a ripple outputs.”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329 · cited 1×
“Lots of currentsbased methods are proposed in [8] and [28] for multilevel converter.”
MethodOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300 · cited 1×
“Recently, load current analysis method, current sections analysis in dq-coordinate, and symmetry analysis based on allelic points are proposed in [22]–[24], these methods perform well in fault detection for their fair robustness to variable load and speed, as well as effective and accurate fault location.”
MethodJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Haar wavelets for efficient similarity search of time-series: with and without time warping
Chan, F. K., Fu, A. W.-C., & Yu, C. (2003) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2003.1198399 · Cited by 261
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241 · cited 1×
“A fault diagnostic method [26] on the basis of the radius of the concordia current pattern is proposed for grid-connected neutral-point-clamped inverter system.”
MethodJlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212 · cited 2×
“Model-based methods are proposed in [19]–[21], these methods are effective, fast and low cost, however, they are poor in robustness and sensitive to parameters.”
MethodRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194 · cited 1×
“Normalized dc current methods are proposed in [17] and [18], these methods have a major drawback of being load dependant and inapplicable to a closed-loop control scheme.”
MethodGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191 · cited 1×
“In [31], mixed logical dynamic model and generated residual are used for open-circuit fault diagnosis in a single-phase rectifier.”
MethodWu, F., & Zhao, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2422131 · Cited by 181 · cited 6×
“An, L.-Z. Sun, K. Zhao, and L. Sun, “Switching function modelbased fast-diagnostic method of open-switch faults in inverters without sensors,” IEEE Trans.”
BackgroundMethodSelf-citationSpADe: On Shape-based Pattern Detection in Streaming Time Series
Chen, Y., Nascimento, M. A., Ooi, B. C., & Tung, A. K. H. (2007) · IEEE International Conference on Data Engineering (ICDE) · doi:10.1109/icde.2007.367924 · Cited by 181 · cited 1×
“Traditional SMs in signal processing, such as ED, CC, and CA, are sensitive to shifting, scaling, and time warpings [36]–[38], these exist in reconstructed CLs when an open-circuit fault occurs.”
BackgroundCaseiro, L. M. A., & Mendes, A. M. S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2341558 · Cited by 170 · cited 1×
“In [30], the instant converter voltage error is used for failure analysis in three-level neutralpoint-clamped boost rectifier, it can detect and identify faults when the line current in the affected phase is reduced to zero.”
MethodLee, J.-S., & Lee, K. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2316228 · Cited by 152 · cited 1×
“Lots of currentsbased methods are proposed in [8] and [28] for multilevel converter.”
MethodZhang, J., Zhao, J., Zhou, D., & Huang, C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2301167 · Cited by 144
Self-citationPerformance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers
Rothenhagen, K., & Fuchs, F. W. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1354769 · Cited by 141 · cited 1×
“Normalized dc current methods are proposed in [17] and [18], these methods have a major drawback of being load dependant and inapplicable to a closed-loop control scheme.”
MethodFault Detection for IGBT Using Adaptive Thresholds During the Turn-on Transient
Rodríguez-Blanco, M. A., Vázquez-Pérez, A., Hernández-González, L., Golikov, V., Aguayo-Alquicira, J., & May-Alarcón, M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2364154 · Cited by 113 · cited 1×
“The strong reliability demand of power device makes the development of fault diagnosis methods become a hotspot during the last years [6]–[9].”
BackgroundDC–DC Converters Dynamic Modeling With State Observer-Based Parameter Estimation
Renaudineau, H., Martin, J., Nahid‐Mobarakeh, B., & Pierfederici, S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2334363 · Cited by 105
Diagnosis and Fault-Tolerant Control of Three-Phase AC–DC PWM Converter Systems
Im, W.-S., Kim, J.-M., Lee, D., & Lee, K. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2255111 · Cited by 104 · cited 2×
“Current angle-based method [32] 1/4cycle Low Medium Low Low Single”
MethodVoltage source inverter fault diagnosis in variable speed AC drives, by Park's vector approach
Mendes, A. M. S. (1998) · Seventh International Conference on Power Electronics and Variable Speed Drives · doi:10.1049/cp:19980607 · Cited by 102 · cited 1×
“In two-level three-phase voltage-source inverter (VSI), the Park’s vector approach was first proposed in [16] as a fault diagnostic tool.”
MethodFault diagnosis scheme for open‐circuit faults in field‐oriented control induction motor drives
Espinoza‐Trejo, D. R., Campos‐Delgado, D. U., Bossio, G., Bárcenas, E., Hernández‐Díez, J. E., & Lugo‐Cordero, L. F. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2012.0256 · Cited by 78 · cited 1×
“Model-based methods are proposed in [19]–[21], these methods are effective, fast and low cost, however, they are poor in robustness and sensitive to parameters.”
MethodDiagnosis Methods for IGBT Open Switch Fault Applied to 3-Phase AC/DC PWM Converter
Im, W.-S., Kim, J.-S., Kim, J.-M., Lee, D., & Lee, K. (2012) · Journal of Power Electronics · doi:10.6113/jpe.2012.12.1.120 · Cited by 72 · cited 2×
“Modified Park’s vector method [33] > 2cycles Low High Low Low Single”
MethodOpen-Circuit Fault Detection and Diagnosis in Matrix Converters
Brunson, C., Empringham, L., Lillo, L. D., Wheeler, P. W., & Clare, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2364152 · Cited by 61 · cited 1×
“Fast and low cost fault detection and location for matrix converter are proposed in [25] based on an electrical circuit analysis.”
BackgroundLow-cost diagnostic method for open-switch faults in inverters
An, Q. T., Sun, L. Z., Sun, L., & Jahns, T. M. (2010) · Electronics Letters · doi:10.1049/el.2010.0611 · Cited by 30 · cited 1×
“Fair robustness, fast detection time, and effective location can be achieved in some voltage-based methods [13]–[15] at the cost of extra voltage sensors or electrical circuits.”
BackgroundKhomfoi, S., Sae-Kok, W., & Ngamroo, I. (2011) · Journal of Power Electronics · doi:10.6113/jpe.2011.11.6.801 · Cited by 21 · cited 1×
“In [34], a combination of the absolute normalized dc current method is proposed.”
MethodChoi, U., & Lee, K. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342254 · Cited by 20 · cited 1×
“Method based on a normalized average phase current and a negative reactive current injection is proposed in [27] for fault detection in T-type three-level inverter system.”
MethodSelf-similar fractal sets: theory and procedure
Casey, S. D., & Reingold, N. F. (1994) · IEEE Computer Graphics and Applications · doi:10.1109/38.279048 · Cited by 16 · cited 1×
“For a periodic signal, feature in a period can represent all the signal characteristics according to self-similar theory [35].”
BackgroundFault diagnostic device for photovoltaic panels
Wang, W., Liu, A. C.-F., Chung, H. S.-H., Lau, R. W.-H., Zhang, J., & Lo, A. W.-L. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104719 · Cited by 3 · cited 1×
“Dynamic current–voltage characteristics are used in [29] for fault diagnosis of photovoltaic panels.”
Background
Research works printed but not linked: 2
- 10.1109/tie.2015.2417501 · DOI · Paper page
- doki?, 2015, Power Electronics-converters and Regulators
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[270] Topology symmetry analysis based on signal statistical parameters”
BackgroundMethodJlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Current similarity analysis for open-circuit fault diagnosis in the three-phase PWM rectifier is presented in [15].”
BackgroundYang, C., Gui, W., Chen, Z., Zhang, J., Peng, T., Yang, C., Karimi, H. R., & Ding, S. X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2924487 · Cited by 122
Open-circuit fault diagnosis of power rectifier using sparse autoencoder based deep neural network
Xu, L., Cao, M., Song, B., Zhang, J., Liu, Y., & Alsaadi, F. E. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.05.040 · Cited by 84
Xie, D., & Ge, X. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2873533 · Cited by 82
“methods in [7]–[11] can directly use signals from the control system for fault analysis without additional hardware, such as”
Method
Metadata
- Authors
- Wu, F., & Zhao, J.
- Affiliations
- Huazhong University of Science and Technology (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-05
- Volume
- 32
- Issue
- 5
- Pages
- 3935-3945
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2474705815
- Cited by
- 82
- References
- 39
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 17 · 2023: 6 · 2022: 15 · 2021: 7 · 2020: 7 · 2019: 8 · 2018: 11 · 2017: 6
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (61273174, 61573159)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- open-circuit fault diagnosis, fault classification, shape analysis, current reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.