Online Condition Monitoring of Power MOSFET Gate Oxide Degradation Based on Miller Platform Voltage
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The condition monitoring problem of power devices is significant for diagnostics and prognostics of a switched-mode power supply (SMPS) system. For power mosfet, the gate oxide degradation often occurs in various applications. However, there is no online condition monitoring method for gate oxide degradation so far. In this paper, a new precursor that can be used for online condition monitoring of power mosfet gate oxide degradation is proposed. Gate oxide degradation mechanisms and effect are summarized, and the mosfet turn-on process is analyzed. Then, a theoretical model is established to describe the relationship between miller platform voltage and two types of gate oxide defects, and miller platform voltage is identified as a new precursor. The precursor can be extracted without impacting system operation, thus online condition monitoring can be accomplished. The accelerated degradation test is carried out for power mosfets with both high electric field and gamma irradiation methods, and the degraded devices injection and in situ monitoring of miller platform voltage are conducted on a BOOST circuit to verify the feasibility of the new precursor. Experimental results demonstrate that the new precursor can be applied to online condition monitoring of power mosfet gate oxide degradation in the SMPS system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
Cited by
A Digital Twin Based Estimation Method for Health Indicators of DC–DC Converters
Peng, Y., Zhao, S., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009600 · Cited by 305
Overview of Real-Time Lifetime Prediction and Extension for SiC Power Converters
Ni, Z., Lyu, X., Yadav, O. P., Singh, B. N., Zheng, S., & Cao, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2962503 · Cited by 261
Degradation Assessment and Precursor Identification for SiC MOSFETs Under High Temp Cycling
Ugur, E., Yang, F., Pu, S., Zhao, S., & Akin, B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2891214 · Cited by 159
“Theoretically, the threshold voltage of the SiC MOSFET can be calculated by [17]”
BackgroundA New Complete Condition Monitoring Method for SiC Power MOSFETs
Ugur, E., Xu, C., Yang, F., Pu, S., & Akin, B. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2970668 · Cited by 126
Farhadi, M., Yang, F., Pu, S., Vankayalapati, B. T., & Akin, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3049394 · Cited by 93
Metadata
- Authors
- Ye, X., Chen, C., Wang, Y., Zhai, G., & Vachtsevanos, G. J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-06
- Volume
- 32
- Issue
- 6
- Pages
- 4776-4784
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2515348268
- Cited by
- 129
- References
- 1
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online Condition Monitoring of Power MOSFET Gate Oxide Degradation Based on Miller Platform Voltage. https://app.cochat.ai/papers/10.1109/tpel.2016.2602323
- The paper
- Ye, X., Chen, C., Wang, Y., Zhai, G., & Vachtsevanos, G. J. (2017). Online Condition Monitoring of Power MOSFET Gate Oxide Degradation Based on Miller Platform Voltage. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2602323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.