Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
When LCL-type converter is attached to weak grid, its current control and phase-locked loop (PLL) will interact with each other, via the point of common coupling voltage. Unfortunately, the conventional PLL controller design methods are mainly for PLL independent systems, regardless of the aforesaid interaction. As a consequence, PLL dynamic might deteriorate the grid current control and even leads to instability problem. For this issue, this article proposes an improved design of PLL controller parameters to mitigate the negative effect of PLL on the current control. First, the small-signal model of the current control system considering PLL effect is established, and the system stability with the conventional PLL controller design method is analyzed. Then, an improved design of PLL controller parameters is proposed, and the design guideline is given in detail. With the method, not only the dynamic and static response performance of PLL independent system can be maintained, but also the negative influence of PLL dynamic on the current control can be effectively reduced in weak grid. Moreover, the grid current control has a strong robustness to the grid impedance variation. Finally, the proposed method is validated by the simulation and experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“2943634 loop (PLL) is usually adopted to synchronize the frequency and phase of grid voltage [8].”
BackgroundImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574 · cited 1×
“Therefore, the well-known impedance criterion [38] is directly used to analyze Fig.”
MethodAnalysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334 · cited 1×
“Then, the relationship between the state variable xs in the “s” domain and the control variable xc in the “c” domain is [10]”
BackgroundHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 1×
“W ITH the growing penetration of renewable energy into the power grid, the issues of power quality and stability have received extensive attention in recent years [1], [2].”
BackgroundA phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192 · cited 1×
“and the typical second-order system tuning method [29], [30].”
MethodInput-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117 · cited 2×
“In general, the conventional PLL controller design methods mainly focus on the design of PLL bandwidth, which is usually designed around one-tenth of the current loop bandwidth [24].”
BackgroundMethodDong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709 · cited 4×
“In [9]–[11], the effect of PLL dynamic on the grid current control is analyzed, which indicates that under weak grid (i.”
BackgroundMethodInfluentialAgorreta, J. L., Borrega, M., López, J., & Marroyo, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095429 · Cited by 596 · cited 2×
“Gde(s) is the control delay and can be expressed as [32]”
BackgroundMethodImpedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586 · cited 2×
“Then, the minor loop gain L(s) can be expressed as [33]”
BackgroundAdaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2295201 · Cited by 327 · cited 1×
“In [21] and [22], the system small-signal stability is improved by reducing PLL bandwidth.”
Background
Cited by
Liu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
“Yet, the PLL can induce instability issue in weak grids [9].”
BackgroundUnified Virtual Oscillator Control for Grid-Forming and Grid-Following Converters
Awal, M. A., & Husain, I. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3025748 · Cited by 168
“Sub-synchronous oscillations or even instability triggered by PLLs in weak grid conditions [7], [24] are well known which can be avoided leveraging the proposed controller.”
BackgroundMohammed, N., Ravanji, M. H., Zhou, W., & Bahrani, B. (2023) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2022.3223976 · Cited by 129
Metadata
- Authors
- Zhu, D., Zhou, S., Zou, X., & Kang, Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-05
- Volume
- 35
- Issue
- 5
- Pages
- 4715-4727
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2976250784
- Cited by
- 225
- References
- 18
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.