The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Unified Virtual Oscillator Control for Grid-Forming and Grid-Following Converters
Open accessAbstract
A unified virtual oscillator controller (uVOC) is proposed, which enables a unified analysis, design, and implementation framework for both grid-forming (GFM) and grid-following (GFL) voltage-source converters (VSCs). Oscillator-based GFM controllers, such as dispatchable virtual oscillator control (dVOC), offer a rigorous analytical framework with enhanced synchronization but lack effective fault handling capability, which severely limits practical application. The proposed uVOC facilitates synchronization with an arbitrarily low grid voltage and fast overcurrent limiting; this enables effective fault ride-through unlike existing GFM controllers which typically switch to a back-up controller during the fault. GFM operation with uVOC is achieved in both grid-connected and islanded modes with seamless transitions between the two. In GFL converters, bidirectional power flow control and dc bus voltage regulation are achieved with uVOC. No phase-locked loop (PLL) is required for either GFL or GFM operation circumventing the synchronization issues associated with PLLs in weak grid applications. Detail small-signal models for GFM and GFL operation have been developed, and the systematic design guidelines for controller parameters are provided. The proposed controller is validated through hardware experiments in a hybrid ac-dc microgrid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesizing Virtual Oscillators to Control Islanded Inverters
Johnson, B. B., Sinha, M., Ainsworth, N. G., Dorfler, F., & Dhople, S. V. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2497217 · Cited by 334
Robust Analytic Design of Power-Synchronization Control
Harnefors, L., Hinkkanen, M., Riaz, U., Rahman, F. M. M., & Zhang, L. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2874584 · Cited by 225
Seo, G.-S., Colombino, M., Subotic, I., Johnson, B., Gros, D., & Dorfler, F. (2019) · 2019 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2019.8722028 · Cited by 182
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Grid integration impacts and control strategies for renewable based microgrid
Fazal, S., Enamul Haque, M., Taufiqul Arif, M., Gargoom, A., & Oo, A. M. T. (2023) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2023.103069 · Cited by 74
Wu, X., Wu, S., Wang, F., Wei, C., Li, R., Jiang, X., & Cai, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510361 · Cited by 24
“GFMcontrolschemescanbecategorizedas[6]:droopcontrol [7],synchronverter[8],virtualsynchronousgenerator(VSG) [9],powersynchronizationcontrol[10],synchronouspower control[11],andvirtualoscillatorcontrol[12].”
Metadata
- Authors
- Awal, M. A., & Husain, I.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2021-08
- Volume
- 9
- Issue
- 4
- Pages
- 4573-4586
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W3088915639
- Cited by
- 168
- References
- 3
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unified Virtual Oscillator Control for Grid-Forming and Grid-Following Converters. https://app.cochat.ai/papers/10.1109/jestpe.2020.3025748
- The paper
- Awal, M. A., & Husain, I. (2021). Unified Virtual Oscillator Control for Grid-Forming and Grid-Following Converters. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2020.3025748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.