Topology Analysis and Review of Three-Port DC–DC Converters
The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
In order to realize power flow control among photovoltaic (PV) panel port, battery port, and load port in the distributed photovoltaic power generation system, integrated three-port dc-dc converters (TPCs) are widely adopted. The objective of this article is to provide a comprehensive, comparative, and insightful analysis and overview of these TPCs. First, based on the power transmission and control requirements of the system, five topological structures of three-port dc-dc conversion system (TPCS) composed of two or three two-port dc-dc converters are presented. And the five structures are comparatively analyzed. Second, based on these topological structures, and combing with the basic two-port dc-dc converters, three groups of typical TPCs with different galvanic isolation requirements are derived, respectively, by sharing switches, combining branches, etc., And comprehensive analysis, comparisons, and reviews of these TPCs with different structures of each isolation type are presented with tables and figures. Finally, the comparison results of the three isolation groups are summarized, which leads to a guidance for the selection of TPCs in different applications, and then some suggestions for the future research on TPCs are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
Zhao, C., Round, S. D., & Kolar, J. W. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002056 · Cited by 900 · cited 2×
“12 shows that most of the fully isolated TPCs with “P1S2” and ”P1S3-II” structures have numerous switches due to the use of full-bridge converters except the ones proposed in [67], [75],”
BackgroundSun, K., Zhang, L., Xing, Y., & Guerrero, J. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2127488 · Cited by 674
Family of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488 · cited 1×
“As presented in [5], a family of multiport bidirectional dc–dc converters are derived from a general topology that shows a combination of dc-link and magnetic coupling.”
BackgroundTransformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478 · cited 1×
“[76], and [81] that composed of half-bridge converters and the”
BackgroundThree-Port Bidirectional Converter for Hybrid Fuel Cell Systems
Duarte, J. L., Hendrix, M., & Simoes, M. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889928 · Cited by 441 · cited 2×
“be adopted to further simplify the control system, such as the introduction of decoupling network or decoupling matrices [8], [68], [96] and the strictly restriction of the range of control variables [36], [46], [91].”
MethodReview of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Yang, Y., Li, H., Aichhorn, A., Zheng, J., & Greenleaf, M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2282504 · Cited by 416 · cited 1×
“than that through path II [9], [10], thus, path I and path II are named primary power transmission path and secondary power transmission path, respectively, which are presented in red and”
BackgroundKrishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411
Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399 · cited 6×
“Thus, the half-bridge converter, forward converter, or flyback converter (including the converters with LLC resonant tank) is more widely used for this structure to simplify the topology [8], [49]–[55], [82], [93].”
BackgroundMethodInfluential
Metadata
- Authors
- Wang, Z., Luo, Q., Wei, Y., Mou, D., Lu, X., & Sun, P.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-11
- Volume
- 35
- Issue
- 11
- Pages
- 11783-11800
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3015574662
- Cited by
- 192
- References
- 81
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Topology Analysis and Review of Three-Port DC–DC Converters. https://app.cochat.ai/papers/10.1109/tpel.2020.2985287
- The paper
- Wang, Z., Luo, Q., Wei, Y., Mou, D., Lu, X., & Sun, P. (2020). Topology Analysis and Review of Three-Port DC–DC Converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2020.2985287
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.