Topology Analysis and Review of Three-Port DC–DC Converters
The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
In order to realize power flow control among photovoltaic (PV) panel port, battery port, and load port in the distributed photovoltaic power generation system, integrated three-port dc-dc converters (TPCs) are widely adopted. The objective of this article is to provide a comprehensive, comparative, and insightful analysis and overview of these TPCs. First, based on the power transmission and control requirements of the system, five topological structures of three-port dc-dc conversion system (TPCS) composed of two or three two-port dc-dc converters are presented. And the five structures are comparatively analyzed. Second, based on these topological structures, and combing with the basic two-port dc-dc converters, three groups of typical TPCs with different galvanic isolation requirements are derived, respectively, by sharing switches, combining branches, etc., And comprehensive analysis, comparisons, and reviews of these TPCs with different structures of each isolation type are presented with tables and figures. Finally, the comparison results of the three isolation groups are summarized, which leads to a guidance for the selection of TPCs in different applications, and then some suggestions for the future research on TPCs are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
Zhao, C., Round, S. D., & Kolar, J. W. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002056 · Cited by 900 · cited 2×
“12 shows that most of the fully isolated TPCs with “P1S2” and ”P1S3-II” structures have numerous switches due to the use of full-bridge converters except the ones proposed in [67], [75],”
BackgroundSun, K., Zhang, L., Xing, Y., & Guerrero, J. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2127488 · Cited by 674
Family of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488 · cited 1×
“As presented in [5], a family of multiport bidirectional dc–dc converters are derived from a general topology that shows a combination of dc-link and magnetic coupling.”
BackgroundTransformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478 · cited 1×
“[76], and [81] that composed of half-bridge converters and the”
BackgroundThree-Port Bidirectional Converter for Hybrid Fuel Cell Systems
Duarte, J. L., Hendrix, M., & Simoes, M. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889928 · Cited by 441 · cited 2×
“be adopted to further simplify the control system, such as the introduction of decoupling network or decoupling matrices [8], [68], [96] and the strictly restriction of the range of control variables [36], [46], [91].”
MethodReview of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Yang, Y., Li, H., Aichhorn, A., Zheng, J., & Greenleaf, M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2282504 · Cited by 416 · cited 1×
“than that through path II [9], [10], thus, path I and path II are named primary power transmission path and secondary power transmission path, respectively, which are presented in red and”
BackgroundKrishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411
Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399 · cited 6×
“Thus, the half-bridge converter, forward converter, or flyback converter (including the converters with LLC resonant tank) is more widely used for this structure to simplify the topology [8], [49]–[55], [82], [93].”
BackgroundMethodInfluentialRodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352 · cited 3×
“According to the different galvanic isolation requirements, TPCs can be classified into three types: nonisolated topologies [11]–[35], fully isolated topologies [66]– [79], and partially isolated topologies [8], [36]–[55], [58]–[65].”
BackgroundMethodTopology Derivation of Nonisolated Three-Port DC–DC Converters From DIC and DOC
Wu, H., Sun, K., Ding, S., & Xing, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2221746 · Cited by 298 · cited 1×
“In [7], based on dual-input converters and dual-output converters, a family of nonisolated TPCs are derived by the combination and optimization construction method,”
MethodOverview of Modulation Strategies for LLC Resonant Converter
Wei, Y., Luo, Q., & Mantooth, A. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975392 · Cited by 296 · cited 3×
“be adopted to further simplify the control system, such as the introduction of decoupling network or decoupling matrices [8], [68], [96] and the strictly restriction of the range of control variables [36], [46], [91].”
MethodSelf-citationA ZVS Bi-Directional DC–DC Converter for Multiple Energy Storage Elements
Liu, D., & Li, H. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.882450 · Cited by 283 · cited 3×
“Then by sharing the diodes D3 and D4 with the switches S5 and S6, the dual-transformerbased asymmetrical triple-port active bridge isolated converter is obtained [66].”
BackgroundMethodNew DC–DC converter for energy storage system interfacing in fuel cell hybrid electric vehicles
Marchesoni, M., & Vacca, C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886650 · Cited by 263 · cited 1×
“Different from the TPCs architected by the basic two-port converters, the topology proposed in [31] is composed of a bidirectional buck and a nonisolated dual-active half-bridge”
Multiport Power Electronic Interface—Concept, Modeling, and Design
Jiang, W., & Fahimi, B. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2093583 · Cited by 259 · cited 1×
“However, it features low device utilization, low power density, low efficiency, and high cost [3], [4].”
BackgroundZhu, H., Zhang, D., Zhang, B., & Zhou, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2393831 · Cited by 232
Wang, Z., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2236580 · Cited by 230
Self-citationWang, L., Wang, Z., & Li, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160405 · Cited by 226
Self-citationSun, X., Shen, Y., Zhu, Y., & Guo, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2358453 · Cited by 215 · cited 1×
“As is proposed in [42] and [43], by replacing the full-bridge”
BackgroundNovel solar cell power supply system using the multiple-input DC-DC converter
Matsuo, H., Kobayashi, K., Sekine, Y., Asano, M., & Wenzhong, L. (2002) · INTELEC - Twentieth International Telecommunications Energy Conference (Cat. No.98CH36263) · doi:10.1109/intlec.1998.793656 · Cited by 208
Samosir, A. S., & Yatim, A. H. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2039458 · Cited by 201 · cited 1×
“The TPCs proposed in [32] and [33] are especially suitable for fuel cell hybrid electric”
BackgroundMira, M. C., Zhang, Z., Knott, A., & Andersen, M. A. E. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2549015 · Cited by 193 · cited 3×
“According to the different galvanic isolation requirements, TPCs can be classified into three types: nonisolated topologies [11]–[35], fully isolated topologies [66]– [79], and partially isolated topologies [8], [36]–[55], [58]–[65].”
BackgroundMethodIntegrated Dual-Output Converter
Ray, O., Josyula, A. P., Mishra, S. K., & Joshi, A. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2327599 · Cited by 187 · cited 1×
“The TPCs proposed in [32] and [33] are especially suitable for fuel cell hybrid electric”
BackgroundA Family of Three-Port Half-Bridge Converters for a Stand-Alone Renewable Power System
Wu, H., Chen, R., Zhang, J., Xing, Y., Hu, H., & Ge, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2125991 · Cited by 182 · cited 1×
“Similarly, for the PV isolated TPC with “P1S2” structure proposed in [50],”
MethodNovel Three-Port Converter With High-Voltage Gain
Chien, L.-J., Chen, C.-C., Chen, J.-F., & Hsieh, Y.-P. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2285477 · Cited by 170
Three-Port DC–DC Converter for Stand-Alone Photovoltaic Systems
Hu, Y., Xiao, W., Cao, W., Ji, B., & Morrow, D. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331343 · Cited by 165
Tri-Modal Half-Bridge Converter Topology for Three-Port Interface
Al-Atrash, H., Tian, F., & Batarseh, I. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889583 · Cited by 161 · cited 2×
“As for electric vehicle applications, based on boost and full-bridge or half-bridge converters, the partially TPCs with “P1S3-I” structure are proposed in [47], [48], [62], and [63].”
BackgroundTao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518725 · Cited by 161
Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
Zhu, H., Zhang, D., Athab, H. S., Wu, B., & Gu, Y. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2378752 · Cited by 158 · cited 4×
“restriction of the range of control variables [36], [46], [91], and the approximate decoupling by specially designed bandwidth for two control loops [49], etc.”
BackgroundMethodInfluentialPWM Plus Phase Angle Shift (PPAS) Control Scheme for Combined Multiport DC/DC Converters
Li, W., Xiao, J., Zhao, Y., & He, X. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2163826 · Cited by 157 · cited 2×
“structure proposed in [45] has the minimum leakage current of transformer when the voltage gain M equals 1 theoretically.”
BackgroundAn Isolated Three-Port Bidirectional DC–DC Converter for Photovoltaic Systems With Energy Storage
Zeng, J., Qiao, W., & Qu, L. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2399613 · Cited by 155
Full-Bridge Three-Port Converters With Wide Input Voltage Range for Renewable Power Systems
Wu, H., Sun, K., Chen, R., Hu, H., & Xing, Y. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2188105 · Cited by 153 · cited 1×
“According to the different galvanic isolation requirements, TPCs can be classified into three types: nonisolated topologies [11]–[35], fully isolated topologies [66]– [79], and partially isolated topologies [8], [36]–[55], [58]–[65].”
BackgroundSoft-Switched Nonisolated High Step-Up Three-Port DC–DC Converter for Hybrid Energy Systems
Faraji, R., & Farzanehfard, H. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2791840 · Cited by 153 · cited 1×
“Thus, the half-bridge converter, forward converter, or flyback converter (including the converters with LLC resonant tank) is more widely used for this structure to simplify the topology [8], [49]–[55], [82], [93].”
MethodA PWM and PFM Hybrid Modulated Three-Port Converter for a Standalone PV/Battery Power System
Sun, X., Shen, Y., Li, W., & Wu, H. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2424718 · Cited by 152
Wu, H., Zhang, J., Qin, X., Mu, T., & Xing, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2473002 · Cited by 148 · cited 1×
“Based on this TPC, the topologies proposed in [36]–[44] can be derived.”
MethodA Soft-Switched Three-Port Bidirectional Converter for Fuel Cell and Supercapacitor Applications
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2005.1581982 · Cited by 146
A comprehensive review of photovoltaic systems
Raj, R. E., & Mabel, M. C. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.06.006 · Cited by 146 · cited 1×
“And the distributed photovoltaic power generation turns out to be an important research and application field [1].”
BackgroundVelasco de la Fuente, D., Rodríguez, C. L. T., Garcerá, G., Figueres, E., & Gonzalez, R. O. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196011 · Cited by 144 · cited 1×
“storage elements such as battery should be included to provide continuous and stable power supply for the load [2].”
BackgroundA Dual Half-Bridge LLC Resonant Converter With Magnetic Control for Battery Charger Application
Wei, Y., Luo, Q., Du, X., Altın, N., Nasiri, A., & Alonso, J. M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2922991 · Cited by 142 · cited 1×
“In [99], the MIOS configuration is employed in the distributed dc grid connected PV system, distributed maximum power point tracking is realized to improve the efficiency of”
MethodSelf-citationA Family of Multiport Buck–Boost Converters Based on DC-Link-Inductors (DLIs)
Wu, H., Zhang, J., & Xing, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2307883 · Cited by 140
Idling Port Isolation Control of Three-Port Bidirectional Converter for EVs
Kim, S., Song, H.-S., & Nam, K. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172225 · Cited by 139 · cited 1×
“Also, for this application, many researches on fully isolated TPCs have been done including the ones with “P1S3-II” structure [66,81] and “P1S2” structure [69], [70],”
BackgroundZhang, J., Wu, H., Qin, X., & Xing, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448696 · Cited by 128 · cited 1×
“three-phase bidirectional TPC can be derived [37], [38], which is more suitable for high power application.”
BackgroundAbdelrazek, S. A., & Kamalasadan, S. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2531639 · Cited by 122 · cited 1×
“than that through path II [9], [10], thus, path I and path II are named primary power transmission path and secondary power transmission path, respectively, which are presented in red and”
BackgroundPhattanasak, M., Gavagsaz‐Ghoachani, R., Martin, J., Nahid‐Mobarakeh, B., Pierfederici, S., & Davat, B. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2336975 · Cited by 115
A low cost, triple-voltage bus DC-DC converter for automotive applications
Su, G.-J., & Peng, F. Z. (2005) · Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005. · doi:10.1109/apec.2005.1453116 · Cited by 111 · cited 3×
“be adopted to further simplify the control system, such as the introduction of decoupling network or decoupling matrices [8], [68], [96] and the strictly restriction of the range of control variables [36], [46], [91].”
BackgroundMethodSu, G.-J., & Tang, L. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005386 · Cited by 108 · cited 3×
“Also, for this application, many researches on fully isolated TPCs have been done including the ones with “P1S3-II” structure [66,81] and “P1S2” structure [69], [70],”
BackgroundA Dual-Input High Step-Up DC/DC Converter With ZVT Auxiliary Circuit
Zhu, B., Zeng, Q., Yao, C., Zhao, Y., & Liu, S. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2876303 · Cited by 108 · cited 1×
“Similarly, the topology proposed in [18]–[22], [85], [86],”
BackgroundWang, Y., Han, F., Yang, L., Xu, R., & Liu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2872683 · Cited by 102 · cited 1×
“[94] is derived with a bidirectional boost and two current-fed full-bridge converters.”
BackgroundLu, Y., Sun, K., Wu, H., Dong, X., & Xing, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2822726 · Cited by 98
High Step-Up Bidirectional Isolated Converter With Two Input Power Sources
Wai, R., Lin, C.-Y., & Chang, Y. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2018427 · Cited by 92 · cited 1×
“[92] features simple topology, which takes full advantage of the Fig.”
BackgroundWu, H., Sun, K., Zhu, L., & Xing, Y. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2478140 · Cited by 91
Sato, Y., Uno, M., & Nagata, H. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2912550 · Cited by 88 · cited 1×
“converters systematically, the power flow graphs are adopted in [100].”
BackgroundDecoupling-Controlled Triport Composited DC/DC Converter for Multiple Energy Interface
Li, W., Xu, C., Luo, H., Hu, Y., He, X., & Xia, C. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2385668 · Cited by 87 · cited 1×
“2(i) can be adopted [89], and the corresponding topological structure is shown in Fig.”
BackgroundA family of non-isolated three-port converters for stand-alone renewable power system
Wu, H., Xing, Y., Xia, Y., & Sun, K. (2011) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2011.6119337 · Cited by 84
A Reduced-Part, Triple-Voltage DC–DC Converter for EV/HEV Power Management
Su, G.-J., & Tang, L. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2026989 · Cited by 83 · cited 2×
“As for electric vehicle applications, based on boost and full-bridge or half-bridge converters, the partially TPCs with “P1S3-I” structure are proposed in [47], [48], [62], and [63].”
BackgroundBoost-Integrated Phase-Shift Full-Bridge Converter for Three-Port Interface
Al-Atrash, H., & Batarseh, I. E. (2007) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2007.4342371 · Cited by 79 · cited 1×
“introducing the control variable of secondary-side phase-shift angle, a novel topology can be obtained [39], which can achieve control decoupling in some operation modes, and can work with”
BackgroundMoradisizkoohi, H., Elsayad, N., & Mohammed, O. A. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2908130 · Cited by 79 · cited 2×
“some TPCs cannot be derived from these four configurations such as the TPCs presented in [11]–[22] and [83]–[86], which are actually composed of three basic units.”
BackgroundCoat Circuits for DC–DC Converters to Improve Voltage Conversion Ratio
Zhu, B., Ding, F., & Vilathgamuwa, D. M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2934726 · Cited by 76 · cited 1×
“and [95] can also be derived, which can achieve high integration and high voltage gain with coupled inductor.”
BackgroundTriple-Half-Bridge Bidirectional Converter Controlled by Phase Shift and PWM
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2006.1620700 · Cited by 71 · cited 1×
“12 shows that most of the fully isolated TPCs with “P1S2” and ”P1S3-II” structures have numerous switches due to the use of full-bridge converters except the ones proposed in [67], [75],”
BackgroundA ZVS Three-Port DC/DC Converter for High-Voltage Bus-Based Photovoltaic Systems
Deng, J., Wang, H., & Shang, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2895976 · Cited by 69 · cited 1×
“PWM dc–dc converter proposed in [88] is composed of two buck converters, which is not suitable for the battery backup application that requires a bidirectional converter.”
BackgroundUno, M., Oyama, R., & Sugiyama, K. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2794332 · Cited by 64 · cited 3×
“be adopted to further simplify the control system, such as the introduction of decoupling network or decoupling matrices [8], [68], [96] and the strictly restriction of the range of control variables [36], [46], [91].”
BackgroundMethodDirect MPPT Algorithm for PV Sources With Only Voltage Measurements
Dallago, E., Liberale, A., Miotti, D., & Venchi, G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2389194 · Cited by 64
Non‐isolated high step‐up three‐port converter with single magnetic element for photovoltaic systems
Honarjoo, B., Madani, S. M., Niroomand, M., & Adib, E. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0934 · Cited by 50 · cited 1×
“inductor, the nonisolated high step-up TPC can be derived [17].”
BackgroundFarakhor, A., Abapour, M., & Sabahi, M. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2018.5633 · Cited by 50 · cited 1×
“Thus, the half-bridge converter, forward converter, or flyback converter (including the converters with LLC resonant tank) is more widely used for this structure to simplify the topology [8], [49]–[55], [82], [93].”
MethodDing, S., Wu, H., Xing, Y., Fang, Y., & Ma, X. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520435 · Cited by 49
A non-isolated three-port converter for stand-alone renewable power system
Zhou, Z., Wu, H., Ma, X., & Xing, Y. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389360 · Cited by 48 · cited 3×
“According to the different galvanic isolation requirements, TPCs can be classified into three types: nonisolated topologies [11]–[35], fully isolated topologies [66]– [79], and partially isolated topologies [8], [36]–[55], [58]–[65].”
BackgroundWang, Z., & Li, H. (2011) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2011.5744611 · Cited by 46 · cited 1×
“three-phase bidirectional TPC can be derived [37], [38], which is more suitable for high power application.”
BackgroundSelf-citationA Three-Port LLC Resonant DC/DC Converter
Zhang, J., Jiang, W., Jiang, T., Shao, S., Sun, Y., Hu, B., & Zhang, J. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2902425 · Cited by 45 · cited 1×
“To be applied for high-voltage bus-based PV systems, the high step-up TPC is proposed in [90], which is derived from the combination of the interleaved boost converter and active voltage six-folder rectifier.”
MethodHigh efficiency non-isolated three port DC-DC converter for PV-battery systems
Mañez, K. T., Anthon, A., Zhang, Z., Ouyang, Z., & Franke, T. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512568 · Cited by 44 · cited 1×
“As a note, although the topology proposed in [13] is derived based on “P1S2” structure, due to the large difference between the battery voltage and load voltage, the duty cycle of B2L converter is large, thus leading to high current stress of the”
BackgroundChen, Y., Wen, G., Li, P., Kang, Y., & Chen, J. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520434 · Cited by 43 · cited 1×
“Nonisolated TPC with other structures: Using the same deduction method, the nonisolated TPC topology with “P2S2” structure proposed in [23] and [24] can be derived.”
MethodPhattanasak, M., Gavagsaz‐Ghoachani, R., Martin, J., Pierfederici, S., & Davat, B. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6063878 · Cited by 42 · cited 1×
“Also, for this application, many researches on fully isolated TPCs have been done including the ones with “P1S3-II” structure [66,81] and “P1S2” structure [69], [70],”
BackgroundA three-port half-bridge converter with synchronous rectification for renewable energy application
Wu, H., Xing, Y., Chen, R., Zhang, J., Sun, K., & Ge, H. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6064220 · Cited by 33
Zhao, J., Iu, H. H., Fernando, T. L., An, L., & Lu, D. D. (2015) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2015.7169191 · Cited by 26 · cited 1×
“Nonisolated TPC with other structures: Using the same deduction method, the nonisolated TPC topology with “P2S2” structure proposed in [23] and [24] can be derived.”
MethodNovel topology and control of a non-isolated three port DC-DC converter for PV-battery power system
Zhang, B., Wang, P., Bei, T., Li, X., Che, Y., & Wang, G. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056089 · Cited by 23 · cited 1×
“Based on the “P2S2” structure, the topologies that contain only one inductor can be derived [25], [26].”
BackgroundA family of cost-efficient integrated single-switch three-port converters
Wen, G., Chen, Y., & Kang, Y. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520431 · Cited by 23 · cited 2×
“Similarly, the topology proposed in [18]–[22], [85], [86],”
BackgroundDynamical modeling of the non-isolated single-inductor three-port converter
Chen, Y., Zhang, P., Zou, X., & Kang, Y. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803591 · Cited by 19 · cited 1×
“Based on the “P2S2” structure, the topologies that contain only one inductor can be derived [25], [26].”
BackgroundNon-isolated multi-port converter integrating PWM and phase-shift converters
Sato, Y., Nagata, H., & Uno, M. (2017) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2017.8228021 · Cited by 18
Optimal idling control strategy for three-port full-bridge converter
Jiang, Y., Liu, F., Ruan, X., & Wang, L. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6869623 · Cited by 15
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2006) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2006.347772 · Cited by 14 · cited 1×
“As for electric vehicle applications, based on boost and full-bridge or half-bridge converters, the partially TPCs with “P1S3-I” structure are proposed in [47], [48], [62], and [63].”
Background
Metadata
- Authors
- Wang, Z., Luo, Q., Wei, Y., Mou, D., Lu, X., & Sun, P.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-11
- Volume
- 35
- Issue
- 11
- Pages
- 11783-11800
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3015574662
- Cited by
- 192
- References
- 81
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.