Transport Lattice Approach to Describing Cell Electroporation: Use of a Local Asymptotic Model
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electroporation has been widely used to manipulate cells and tissues, but quantitative understanding of electrical behavior in cell membranes has not been achieved. According to the transient aqueous pore hypothesis, pore creation and expansion is a nonlinear, hysteretic process. Different membrane sites respond locally to their own transmembrane voltage history, so that a self-consistent description should involve the interaction of many different regions of a cell membrane model and its aqueous electrolytes. A transport lattice system model of a cell allows active and passive interaction models for local transport and storage of charge to be combined, yielding approximate solutions for this highly interacting system. Here, we use an asymptotic model for local membrane electroporation, which involves solving an ordinary differential equation for each local membrane area of the system model, subject to constraints imposed by self-consistency throughout the system model of the cell. To illustrate this approach, we first treat a model for a space- and voltage-clamped skeletal muscle cell. We then create and analyze models of a circular cell and of a budding yeast cell pair, both of which exhibit electroporation when exposed to pulsed electric fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential, impedance, and rectification in membranes
Goldman, D. E. (1943) · Journal of General Physiology · doi:10.1085/jgp.27.1.37 · Cited by 2,777 · cited 1×
“In principle, the membrane subcircuit could include the full Smoluchowski Equation (1), the Goldman Equation for the resting potential [41], [42], or other candidate mechanisms that influence .”
BackgroundAn approach to electrical modeling of single and multiple cells
Gowrishankar, T. R., & Weaver, J. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0636434100 · Cited by 204 · cited 2×
“We have developed a transport lattice approach to the simulation of electrical, chemical, and thermal transport in multi-cellular and subcellular systems [14].”
BackgroundMethodSecond-order model of membrane electric field induced by alternating external electric fields
Kotnik, T., & Miklavcic, D. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855935 · Cited by 150 · cited 1×
“Often, the internal conductivity is set to a smaller value (e.g., 0.3 S m [18]) in cell simulations, which is presumably done to take into account the effective increase in resistance due to subcellular structures.”
BackgroundInfluential
Cited by
Modeling Electroporation in a Single Cell
Krassowska, W., & Filev, P. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.094235 · Cited by 501
“A previous model from our group (24), as well as recent work of Weaver’s group (25,26), includes explicit creation of pores in the cell membrane.”
MethodNanoelectropulse-driven membrane perturbation and small molecule permeabilization
Vernier, P. T., Sun, Y., & Gundersen, M. A. (2006) · BMC Cell Biology · doi:10.1186/1471-2121-7-37 · Cited by 319
Weaver, J. C., Smith, K. C., Esser, A. T., Son, R. S., & Gowrishankar, T. R. (2012) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2012.02.007 · Cited by 285
Self-citationDiverse Effects of Nanosecond Pulsed Electric Fields on Cells and Tissues
Beebe, S. J., White, J., Blackmore, P. F., Deng, Y., Somers, K., & Schoenbach, K. H. (2003) · DNA and Cell Biology · doi:10.1089/104454903322624993 · Cited by 250
Plasma Membrane Voltage Changes during Nanosecond Pulsed Electric Field Exposure
Frey, W., White, J. A., Price, R. O., Blackmore, P. F., Joshi, R. P., Nuccitelli, R., Beebe, S. J., Schoenbach, K. H., & Kolb, J. F. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.072777 · Cited by 241
“A possible explanation might be that during the first 15 ns the electric field creates a multitude of small nanopores across the cell membrane previously referred to as ‘‘supra-electroporation’’ (30).”
BackgroundNumerical Determination of Transmembrane Voltage Induced on Irregularly Shaped Cells
Pucihar, G., Kotnik, T., Valič, B., & Miklavčič, D. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9076-2 · Cited by 209
Microdosimetry for conventional and supra-electroporation in cells with organelles
Gowrishankar, T. R., Esser, A. T., Vasilkoski, Z., Smith, K. C., & Weaver, J. C. (2006) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2006.01.094 · Cited by 198
“of the asymptotic model using circuit elements was presented in an earlier paper [39].”
BackgroundMethodInfluentialSelf-citationInduction of Cell Death Mechanisms and Apoptosis by Nanosecond Pulsed Electric Fields (nsPEFs)
Beebe, S., Sain, N., & Ren, W. (2013) · Cells · doi:10.3390/cells2010136 · Cited by 185
“Furthermore, unlike electroporation pores, nsPEFs generate large numbers of nanopores in all cell membranes a phenomenon called supra-electroporation [20,21].”
BackgroundDefect-Mediated Trafficking across Cell Membranes: Insights from in Silico Modeling
Gurtovenko, A. A., Anwar, J., & Vattulainen, I. (2010) · Chemical Reviews · doi:10.1021/cr1000783 · Cited by 179
Pucihar, G., Miklavcic, D., & Kotnik, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2014244 · Cited by 175
“The advantage of this approach is that the expressions describing ∆Ψ and electroporation are easy to implement, but these models are generally based on either simplified geometry [30], [33], [45], or concentrated parameters such as RC-lattices [40]–[42].”
BackgroundMembrane electroporation: The absolute rate equation and nanosecond time scale pore creation
Vasilkoski, Z., Esser, A. T., Gowrishankar, T. R., & Weaver, J. C. (2006) · Physical Review E · doi:10.1103/physreve.74.021904 · Cited by 170
Self-citationBasic Features of a Cell Electroporation Model: Illustrative Behavior for Two Very Different Pulses
Son, R. S., Smith, K. C., Gowrishankar, T. R., Vernier, P. T., & Weaver, J. C. (2014) · The Journal of Membrane Biology · doi:10.1007/s00232-014-9699-z · Cited by 99
Self-citationStewart Jr., D. A., Gowrishankar, T. R., Smith, K. C., & Weaver, J. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856030 · Cited by 52
Metadata
- Authors
- Stewart, D. A., Gowrishankar, T. R., & Weaver, J. C.
- Venue
- IEEE Transactions on Plasma Science
- Published
- 2004-08
- Volume
- 32
- Issue
- 4
- Pages
- 1696-1708
- ISSN
- 0093-3813 (ISSN-L)
- OpenAlex
- W2124188942
- Cited by
- 117
- References
- 3
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.