The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Condition monitoring techniques for electrical equipment-a literature survey
Abstract
Increasing interest has been seen in condition monitoring (CM) techniques for electrical equipment, mainly including transformer, generator, and induction motor in power plants, because CM has the potential to reduce operating costs, enhance the reliability of operation, and improve power supply and service to customers. Literatures are accumulated on developing intelligent CM systems with advanced practicability, sensitivity, reliability and automation. A literature survey is felt necessary with an aim to reflect the state of the art development in this important area. After introducing the concepts and functions of CM, this paper describes the popular monitoring methods for and research status of CM on transformer, generator, and induction motor, respectively. The paper also points out the potential benefits through the utilization of advanced signal processing and artificial intelligence techniques in developing novel CM schemes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
Benbouzid, M. E. H., Vieira, M., & Theys, C. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737588 · Cited by 378
Condition monitoring of electrical machines
Tavner, P., & Penman, J. (1987) · Durham Research Online (Durham University) · Cited by 353
Paya, B. A., Esat, I. I., & Badi, M. N. M. (1997) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1997.0090 · Cited by 327
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345492 · Cited by 264
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475698 · Cited by 239
Monitoring of defects in induction motors through air-gap torque observation
Hsu, J. S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464514 · Cited by 217
Thomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Cited by
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
Smart Transmission Grid: Vision and Framework
Li, F., Qiao, W., Sun, H., Wan, H., Wang, J., Xia, Y., Xu, Z., & Zhang, P. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2053726 · Cited by 961
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
A Review of Data-Driven Decision-Making Methods for Industry 4.0 Maintenance Applications
Bousdekis, A., Lepenioti, K., Apostolou, D., & Mentzas, G. (2021) · Electronics · doi:10.3390/electronics10070828 · Cited by 334
An overview of state-of-the-art partial discharge analysis techniques for condition monitoring
Wu, M., Cao, H., Cao, J., Nguyen, H.-L., Gomes, J. B., & Krishnaswamy, S. P. (2015) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2015.7303259 · Cited by 285
Metadata
- Authors
- Han, Y., & Song, Y. H.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2003-01
- Volume
- 18
- Issue
- 1
- Pages
- 4-13
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2101260915
- Cited by
- 381
- References
- 30
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condition monitoring techniques for electrical equipment-a literature survey. https://app.cochat.ai/papers/10.1109/tpwrd.2002.801425
- The paper
- Han, Y., & Song, Y. H. (2003). Condition monitoring techniques for electrical equipment-a literature survey. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2002.801425
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.