VSC Transmission Operating Under Unbalanced AC Conditions—Analysis and Control Design
Abstract
This work presents an analysis and a new control design of a voltage-source converter (VSC) transmission system operating under unbalanced network conditions. The system is analyzed in the positive and negative synchronous reference frames. The proposed control strategy contains a main controller and an auxiliary controller. The main controller is implemented in the positive d-q frame using decoupling control without involving positive/negative-sequence decomposition. The auxiliary controller is implemented in the negative-sequence d-q frame using cross-coupling control of negative-sequence current. Simulation results using the SIMULINK power system blockset show good performance of the proposed control strategy for a 300-MW 300-kV dc VSC transmission system during both balanced conditions and unbalanced conditions as may be caused by a solid single-phase-to-ground fault.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
“control scheme based on coordinates [22]–[24] can also be adopted in MMC and no further discussion is given here.”
BackgroundSelf-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Synchronous Generator Emulation Control Strategy for Voltage Source Converter (VSC) Stations
Guan, M., Pan, W., Zhang, J., Hao, Q., Cheng, J., & Zheng, X. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2384498 · Cited by 432
Grid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Xu, L., Yao, L., & Sasse, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901306 · Cited by 428
Self-citationMultiterminal DC Wind Farm Collection Grid Internal Fault Analysis and Protection Design
Yang, J., Fletcher, J. E., & O'Reilly, J. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2044813 · Cited by 321
Metadata
- Authors
- Xu, L., Andersen, B. R., & Cartwright, P.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2005-01
- Volume
- 20
- Issue
- 1
- Pages
- 427-434
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2095712469
- Cited by
- 231
- References
- 0
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.