The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Abstract
This paper proposes a protection scheme which utilizes modern voltage-source converters as fast-acting current-limiting circuit breakers. This paper investigates the main challenges of detecting and localizing a fault, and interrupting it as quickly as possible in a multiterminal dc system. A system protection scheme consisting of smart relays associated with converters has been developed. The protection relays monitor local quantities to detect and isolate disturbances/faults. It is shown that overcurrent-based schemes can be adopted for these relays to meet the fast response requirements. The effectiveness of the proposed protection scheme is illustrated through simulations
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Quality Enhancement Using Custom Power Devices
Ghosh, A., & Ledwich, G. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1153-3 · Cited by 1,365
DC distribution for industrial systems: opportunities and challenges
Baran, M. E., & Mahajan, N. R. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.818969 · Cited by 582
Self-citationInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Application of HVDC Light to power system enhancement
Asplund, G. (2002) · 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077) · doi:10.1109/pesw.2000.847202 · Cited by 176
The Gotland HVDC Light project - experiences from trial and commercial operation
Axelsson, U. (2001) · International Conference and Exhibition on Electricity Distribution (CIRED) · doi:10.1049/cp:20010675 · Cited by 96
The emitter turn-off thyristor-based DC circuit breaker
Xu, Z., Zhang, B., Sirisukprasert, S., et al. (2003) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.2002.985000 · Cited by 65
A new boost type rectifier for a DC power supply with frequent output short circuit
Nho, E., Kim, I.-D., & Lipo, T. A. (2003) · doi:10.1109/ias.1999.801651 · Cited by 6
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
Protection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
DC Microgrid Protection: A Comprehensive Review
Beheshtaein, S., Cuzner, R. M., Forouzesh, M., Savaghebi, M., & Guerrero, J. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2904588 · Cited by 365
Metadata
- Authors
- Baran, M. E., & Mahajan, N. R.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2007-01
- Volume
- 22
- Issue
- 1
- Pages
- 406-412
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2036302375
- Cited by
- 380
- References
- 10
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.