Active Redundant Submodule Configuration in Modular Multilevel Converters
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The modular multilevel converter (MMC) is based on the cascaded connection of identical submodules (SMs) enabling additional redundancies. This paper proposes the configuration of the MMC topology with redundant SMs and demonstrates the effects of active redundancies. The proposed configuration decreases the switching frequency per SM while reducing the SM capacitor voltage ripples. An analytical model for determining the SM capacitor voltage ripple and voltage dynamics is derived. The results from the analytical model are compared with the switching model for a 21-level MMC with five redundant (25 in total) SMs per arm. Experimental results based on a single-phase laboratory prototype with five SMs per arm and a single redundant cell further illustrate the operation and verify the derived mathematical model and simulation results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“and lower switching frequency, resulting in more efficient operation of the overall conversion system [3].”
BackgroundSelf-citationAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 2×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundVSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“Multilevel converters are particularly suitable for high-power applications, such as high-voltage direct current (HVDC) transmission [1], static synchronous compensators”
BackgroundSelf-citationControl and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“The MMC is a member of the broad family of cascade multilevel converters [17] and features significant ad-”
BackgroundModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Gnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“as steady-state [24] and dynamic [25] analysis of the converter”
Background
Cited by
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
“3) Reliability: The MMC, due to its structural modularity, can improve fault tolerance by augmenting redundant SMs in its structure [12], [68], thereby, increasing its reliability.”
BackgroundSurvey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“always operate in normal/healthy conditions; therefore, the average switching frequency per module can be reduced and the task of voltage balancing can be simplified as detailed in [51].”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
“There are two types of the SM reserve mode for the MMC: the cold reserve mode and the spinning reserve mode [39], [40].”
MethodModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
Self-citationTowards Long Lifetime Battery: AI-Based Manufacturing and Management
Liu, K., Wei, Z., Zhang, C., Shang, Y., Teodorescu, R., & Han, Q.-L. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.105599 · Cited by 302
“Diverse reconfigurable topologies with 1~6 switches per cell have been reported in the existing literature [52].”
BackgroundMerlin, M. M. C., & Green, T. C. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0328 · Cited by 216
Fault-Tolerant Approach for Modular Multilevel Converters Under Submodule Faults
Deng, F., Tian, Y., Zhu, R., & Chen, Z. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2538201 · Cited by 154
“Furthermore, the lower capacitor voltage in the proposed approach could increase the utilization ratio of the SMs in comparison with the conventional methods [20], [25], [26] under normal situation without faults, which could produce more voltage levels for a lower total harmonic distortion and improve power quality.”
BackgroundResultInfluentialReliable Modular Multilevel Converter Fault Detection With Redundant Voltage Sensor
Picas, R., Zaragoza, J., Pou, J., & Ceballos, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2526684 · Cited by 134
“Since the technique of “active” redundant SMs [21] is used, the system can maintain its performance without using the faulty SM anymore.”
BackgroundMethodSelf-citationKomsiyska, L., Buchberger, T., Diehl, S., Ehrensberger, M., Hanzl, C., Hartmann, C., Hölzle, M., Kleiner, J., Lewerenz, M., Liebhart, B., et al. (2021) · Energies · doi:10.3390/en14185989 · Cited by 143
Xiao, Q., Jin, Y., Jia, H., Tang, Y. K., Cupertino, A. F., Mu, Y., Teodorescu, R., Blaabjerg, F., & Pou, J. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3283286 · Cited by 139
Self-citationFault-Tolerant Control of MMC With Hot Reserved Submodules Based on Carrier Phase Shift Modulation
Li, K., Yuan, L., Zhao, Z., Lu, S., & Zhang, Y. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2628762 · Cited by 133
“Then subsequent to that, the reserved SMs are often utilized in practice to keep MMC working normally without being interrupted until the next regular maintenance [14], which is the fault-tolerant operation of MMC, namely the major focus of this paper.”
BackgroundZhang, Y., Wang, H., Wang, Z., Yang, Y., & Blaabjerg, F. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2823664 · Cited by 128
“, redundancy [10] and fault protection [11]).”
Picas, R., Ceballos, S., Pou, J., Zaragoza, J., Konstantinou, G., & Agelidis, V. G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2368055 · Cited by 116
Self-citationOperation and Control Methods of Modular Multilevel Converters in Unbalanced AC Grids: A Review
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., & Pou, J. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2856505 · Cited by 115
Self-citationLi, B., Zhang, Y., Yang, R., Xu, R., Xu, D., & Wang, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2392778 · Cited by 116
Mission Profile-Based System-Level Reliability Prediction Method for Modular Multilevel Converters
Zhang, Y., Wang, H., Wang, Z., Blaabjerg, F., & Saeedifard, M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2957826 · Cited by 107
Review of MVDC Applications, Technologies, and Future Prospects
Coffey, S., Timmers, V. R. J. H., Li, R., Wu, G., & Egea‐Àlvarez, A. (2021) · Energies · doi:10.3390/en14248294 · Cited by 102
Closed-Loop Precharge Control of Modular Multilevel Converters During Start-Up Processes
Li, B., Xu, D., Zhang, Y., Yang, R., Wang, G., Wang, W., & Xu, D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2334055 · Cited by 97
“1It should be noted that if there are redundant SMs [20], this voltage difference will be larger.”
BackgroundReliability Modeling and Evaluation of MMCs Under Different Redundancy Schemes
Guo, J., Wang, X., Liang, J., Pang, H., & Goncalves, J. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2715664 · Cited by 101
“In the conventional mode, the number of “on-state” SMs in a phase unit is always equal to k [21], [22], which means the number of “on-state” SMs in each arm during a fundamental period ranges from 0 to k.”
BackgroundOn the Redundancy Strategies of Modular Multilevel Converters
Farias, J. V. M., Cupertino, A. F., Pereira, H. A., Seleme, S. I., & Teodorescu, R. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2713394 · Cited by 89
“In the second approach, the average voltage of the SMs is maintained constant even during failures, as discussed in [16].”
BackgroundReliability Model of MMC Considering Periodic Preventive Maintenance
Wang, B., Wang, X., Bie, Z., Judge, P. D., Wang, X., & Green, T. C. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2602888 · Cited by 92
“A typical configuration of the MMC topology [2] is shown in Fig.”
BackgroundMethodReliability and Cost-Oriented Analysis, Comparison and Selection of Multi-Level MVdc Converters
Abeynayake, G., Li, G., Joseph, T., Liang, J., & Ming, W. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3051531 · Cited by 87
“The benefits of using active redundant sub-modules (SMs) for improving the reliability of MMCs have been discussed in [24], [25].”
BackgroundControl of Circulating Currents in Modular Multilevel Converters Through Redundant Voltage Levels
Konstantinou, G., Pou, J., Ceballos, S., Picas, R., Zaragoza, J., & Agelidis, V. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2512842 · Cited by 75
“MMCs offer an expandable and redundant configuration [5] capable of generating a large number of voltage levels and providing high-quality voltage and current waveforms with high efficiency and reduced switching losses [3], [4].”
BackgroundSelf-citationKonstantinou, G. S., Pou, J., Ceballos, S., Darus, R., & Agelidis, V. G. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2416759 · Cited by 77
“The topology offers significant operational redundancies [4] and various submodule (SM) configurations [5], allowing additional functionalities, such as energy storage [6].”
BackgroundSelf-citationComparison and evaluation of sub-module configurations in modular multilevel converters
Konstantinou, G., Zhang, J., Ceballos, S., Pou, J., & Agelidis, V. G. (2015) · 2015 IEEE 11th International Conference on Power Electronics and Drive Systems · doi:10.1109/peds.2015.7203440 · Cited by 66
“However, during steady-state operation, adding SMs with opposite polarity in the arms of the MMC means that the total number of connected SMs in the phase-leg for a given voltage level will be higher than N [5] adversely affecting the voltage balancing process and adding to the switching frequency of individual SMs.”
BackgroundSelf-citationA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
“A common practice in improving fault tolerance of the MMC and counteracting the impact of any SM failure is to consider a number of redundant SMs within each arm of the MMC [9], [10].”
BackgroundA Diagnosis Strategy for Multiple IGBT Open-Circuit Faults of Modular Multilevel Converters
Chen, X., Liu, J., Deng, Z., Song, S., Du, S., & Wang, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2997963 · Cited by 67
“The reserve mode of the redundant SMs can be classified into two categories: the cold reserve mode, and the active reserve mode [15], [22].”
BackgroundFarzamkia, S., Iman‐Eini, H., Noushak, M., & Hadizadeh, A. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2823659 · Cited by 61
A Hybrid Modular Multilevel Converter Family With Higher Power Density and Efficiency
Liu, J., Dong, D., & Zhang, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3055690 · Cited by 60
“As for the chain-link part, the redundant SMs in hot reserve or cold reserve operation modes have been proposed [41], [42], thus not discussed here.”
BackgroundLi, B., Xu, Z., Ding, J., & Xu, D. (2018) · IEEE Access · doi:10.1109/access.2018.2811904 · Cited by 57
“On the other hand, if additional Nr redundant SMs are employed in each arm, there can be two operation modes: maintaining the capacitor voltage as UC=Udc/Na [24]–[26]; or decreasing the capacitor voltage to UC=Udc/(Na+Nr) [27]–[29].”
BackgroundInfluentialPicas, R., Zaragoza, J., Pou, J., Ceballos, S., Konstantinou, G., & Capella, G. J. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2847621 · Cited by 54
“The addition of SMs in the arms increases the cost of the MMC, but also provides extra benefits to the converter, such as fault tolerance capability and a further reduction in the capacitor voltage ripples [32].”
Self-citationKim, H., Kim, S. M., Chung, Y.-H., Yoo, D.-W., Kim, C., & Hur, K. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2458038 · Cited by 55
“Note that may be different from the number of levels of converter [36].”
BackgroundWang, J., & Tang, Y. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890536 · Cited by 54
“The capacitor voltage in the upper and lower arms will change to [10] { ucp f = N +R N +R−Fp (ũcp 1ω + ũcp 2ω ) + ucp dc ucn f = N +R N +R−Fn (−ũcp 1ω + ũcp 2ω ) + ucn dc (21)”
BackgroundAleenejad, M., Mahmoudi, H., Jafarishiadeh, S., & Ahmadi, R. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2860518 · Cited by 49
“It is worth mentioning that the auxiliary SMs used in [18] are not permanently used during the normal operation of the converter.”
BackgroundMethodPerformance of the modular multilevel converter with redundant submodules
Ahmed, N., Ängquist, L., Antonopoulos, A., Harnefors, L., Norrga, S., & Nee, H. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392712 · Cited by 46
“Unlike [25] and [26], which describe most steady-state properties of the approach to use redundant submodules, the present work provides a detailed analysis of the transients occurring due to submodule failure.”
BackgroundReliability Modeling and Analysis of Hybrid MMCs Under Different Redundancy Schemes
Xie, X., Li, H., McDonald, A., Tan, H., Wu, Y., Yang, T., & Yang, W. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3008281 · Cited by 46
“of each SM [24], but has little impact on failure rates of power devices [16].”
BackgroundGradient-Based Energy Balancing and Current Control for Alternate Arm Converters
Wickramasinghe, H. R., Konstantinou, G. S., & Pou, J. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2785386 · Cited by 42
“In addition to the common characteristics among VSCs, the unique features of MMCs in high-power applications are: i) modularity, ii) scalability, iii) relatively simple capacitor voltage balancing, iv) ability to handle wide power and voltage ratings, and v) redundant configuration [3].”
BackgroundSelf-citationExploiting Redundant Energy of MMC–HVDC to Enhance Frequency Response of Low Inertia AC Grid
Kim, H., Kang, J., Shim, J. W., Beerten, J., Hertem, D. V., Jung, H.-J., Kim, C., & Hur, K. (2019) · IEEE Access · doi:10.1109/access.2019.2942852 · Cited by 44
“The arm of the MMC may contain the active redundant submodules, which means that the number of submodules (NSM ) per arm could be different from the number of levels (Nlevel) of the MMC [22], [23].”
BackgroundIntegration technology and practice for long‐distance offshore wind power in China
Pan, E., Yue, B., Li, X., Zhao, Z., & Zhu, Q. (2020) · Energy Conversion and Economics · doi:10.1049/enc2.12003 · Cited by 41
Rojas, F., Jerez, C., Hackl, C. M., Kalmbach, O., Pereda, J. E., & Lillo, J. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3213508 · Cited by 47
“As a consequence, the switching frequency of each cell is reduced, while the effective converter switching frequency is unaffected and cell capacitor voltage ripples are kept low [112].”
BackgroundAthwer, A., & Darwish, A. (2023) · Energies · doi:10.3390/en16145324 · Cited by 42
“In the second case, when the upper IGBT switch is turned off and the bottom IGBT is switch turned on, the SM capacitor will be bypassed, and thus, the VSM is equal to zero volts, where each arm in the converter acts as a controllable voltage source and the overall output voltages of the converter are effectively contr…”
BackgroundInfluentialNew Scheme of Phase-Shifted Carrier PWM for Modular Multilevel Converter With Redundancy Submodules
Choi, J., Han, B.-M., & Kim, H. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2473101 · Cited by 38
“This letter proposes a new scheme of PSC PWM for theMMC with redundancy SMs to offer a smooth transition for the redundancy SM from the standby state to the startup operation when any SMs break down [4].”
MethodXiao, Q., Wang, J., Jin, Y., Chen, L., Jia, H., Dragičević, T., & Teodorescu, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2967576 · Cited by 38
“Therefore, redundant SMs and fault-tolerant control are necessary for the stable operation of MMC [11].”
BackgroundKang, J., Kim, H., Jung, H.-J., Lee, D. S., Kim, C., Mantooth, H. A., & Hur, K. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2846406 · Cited by 38
“fixed-level mode, which is not shown in this paper, though (see further discussion in [11] and [21]).”
BackgroundMethodResultInfluentialFarzamkia, S., Noushak, M., Iman‐Eini, H., Sadigh, A. K., & Farhangi, S. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2991998 · Cited by 30
Liu, H., Ma, K., Wang, C., & Blaabjerg, F. (2016) · Electric Power Components and Systems · doi:10.1080/15325008.2016.1198439 · Cited by 29
“However, just N sub-modules in the N + M submodules are activated at any time to generate N + 1 level output voltage [49, 50].”
BackgroundNew harmonic mitigation scheme for modular multilevel converter – an experimental approach
Madichetty, S., Dasgupta, A., & Mishra, S. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2014.0028 · Cited by 27
Yin, J., Wu, W., Wei, T., Wu, X., & Huo, Q. (2018) · Energies · doi:10.3390/en12010020 · Cited by 25
Decoupled Control of Modular Multilevel Converters Using Voltage Correcting Modules
Riar, B., & Madawala, U. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2313613 · Cited by 25
“In situations where the number of modules is increased without changing the number of voltage levels, active redundancies of the modules have been used to reduce the capacitor voltage variations and circulating currents [12].”
MethodReliability evaluation of modular multilevel converter based on Markov model
Zhang, L., Zhang, D., Ting, H. U. A., Zhu, J., Chen, G., Wei, T., & Yang, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-019-0515-8 · Cited by 24
Comparison of bipolar sub-modules for the alternate arm converter
Wickramasinghe, H. R., Konstantinou, G. S., & Pou, J. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.01.023 · Cited by 25
Self-citationCui, S., Hu, J., & Doncker, R. D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2911853 · Cited by 24
“The FTO methods of the MMC include the hot-reserving redundant SM concept [7]–[11], cold-reserving redundant SM concept [12], and the neutral shift concept [14]– [16], which is similar to the FTO method utilized in cascade”
MethodMadichetty, S., & Dasgupta, A. (2014) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v4i1.5020 · Cited by 26
“In “Active Redundant Sub-module Configuration in Modular Multilevel Converters” [4], the MLI is based on the cascaded connection of identical sub modules (SMs) enabling additional redundancies.”
BackgroundFarzamkia, S., Iman‐Eini, H., Sadigh, A. K., & Noushak, M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3022984 · Cited by 23
Ma, Y., Lin, H., Wang, X., Wang, Z., & Ze, Z. (2018) · European Conference on Power Electronics and Applications · Cited by 21
Yang, D., Gao, B., Wang, S., & Xiang, H. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20240283 · Cited by 20
Wang, B., Wang, X., Wang, X., Shao, C., & Liu, S. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0450 · Cited by 20
Fault tolerant operation strategy design for modular multilevel converters
Haghnazari, S., Vahedi, H., & Zolghadri, M. R. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793004 · Cited by 17
“In spinning reserve scheme, the redundant cells operate the same way as other cell during MMC normal operation [20].”
BackgroundWu, W., Wu, X., Yin, J., Jing, L., Wang, S., & Li, J. (2017) · Energies · doi:10.3390/en10111827 · Cited by 16
Li, J., Wu, X., Yao, X., Jing, L., Jin, X., Wu, W., Wang, X., & Wang, S. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854809 · Cited by 16
“However, the carrier phase disposition pulse-width modulation (PDPWM) [7]-[8] is very popular in MMC due to its simplicity of implementation, known harmonic waveform characteristics, and low harmonic distortion.”
BackgroundZhang, Y., Wang, H., Wang, Z., & Blaabjerg, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2925590 · Cited by 16
“Although many redundancy schemes [5] and fault protection methods [6] are proposed to improve the reliability of MMCs, these methods usually sacrifices some important characters, such as cost, footprint, and power density.”
Wylie, J., Merlin, M., & Green, T. C. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099246 · Cited by 15
“There are two different documented ways of controlling redundant SMs [7] [10].”
BackgroundAsymmetric overlap and hysteresis current control of zero-current switched alternate arm converter
Wickramasinghe, H. R., Konstantinou, G. S., Pou, J., & Agelidis, V. G. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793990 · Cited by 14
“Inspired by the MMC control method described in [16], the available redundant voltage in arms are used to control the direction of circulating current.”
MethodSelf-citationImpact of Submodule Faults on the Performance of Modular Multilevel Converters
Wang, S., Alsokhiry, F., & Adam, G. P. (2020) · Energies · doi:10.3390/en13164089 · Cited by 14
“Methods for SMs fault detection and identification are proposed in [13–15], while increased MMC resiliency to SM faults through the concept of redundant SMs are discussed in [16] and [17].”
BackgroundSparse AC/AC Modular Multilevel Converter
Alaei, R., Khajehoddin, S. A., & Xu, W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2440271 · Cited by 13
“In addition, due to the modularity of MMC, a few extra modules can be connected to substitute the failed ones [17]–[19].”
BackgroundA Survey and experimental verification of Modular Multilevel Converters
Madichetty, S., Abhijit, D., & Jinka, S. (2014) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v4i3.5914 · Cited by 13
“MODULAR MULTI-LEVEL CONVERTER TOPOLOGIES AND MODULATION TECHNIQUES There are many topologies are existing in literature, after careful review, based on function and its applicability, it has been divided as follows: a) Single star bridge cells (SSBC) b) Single delta bridge cells (SDBC) c) Double star chopper cells(DSC…”
BackgroundYang, S., Tang, Y. K., Tu, P., & Wang, P. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096722 · Cited by 11
“An active redundant sub-module configuration decreasing the sub-module equivalent switching frequency as well as the voltage ripples is proposed in [11].”
BackgroundWang, Z., Yin, X., & Chen, Y. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108048 · Cited by 11
Konstantinou, G. S., Wickramasinghe, H. R., Ceballos, S., & Pou, J. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507725 · Cited by 12
“In addition to the common characteristics among VSCs, the unique features of MMCs in high-power applications are: i) modularity, ii) scalability, iii) relatively simple capacitor voltage balancing, iv) ability to handle wide power and voltage ratings, and v) redundant configuration [4].”
BackgroundSelf-citationA Series Interharmonic Filter for Cascaded H-bridge PV Inverters
Pan, Y., Sangwongwanich, A., Yang, Y., & Blaabjerg, F. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235745 · Cited by 11
“, by circulating reactive power flow) [19].”
Liang, G., Farivar, G. G., Yadav, G. N. B., Rodríguez, E., & Pou, J. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589060 · Cited by 10
“However, the investigations in [8]–[11] did not consider the use of redundant SMs, which are commonly employed in MMCs to aid operation during SM failures [12].”
BackgroundSelf-citationAn Improved Phase-Shifted Carrier PWM for Modular Multilevel Converters with Redundancy Sub-Modules
Choi, J., & Han, B.-M. (2016) · Journal of Power Electronics · doi:10.6113/jpe.2016.16.2.473 · Cited by 10
A Modular Magnetic Linked Converter Station for Offshore Power Transfer Through HVDC Link
Rahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3206691 · Cited by 10
“However, due to the modular nature of the front-end interface, redundant HB modules can be employed to bypass the faulty modules, as reported in [20].”
A Review of MVDC Smart Grids Technologies and Components
Ciniello, V., Loggia, R., Martirano, L., & Lauria, S. (2024) · IEEE/IAS Industrial and Commercial Power Systems Technical Conference · doi:10.1109/icps60943.2024.10563506 · Cited by 10
“An increasing number of SMs placed on each arm is required to limit harmonics injected into the network [30-31].”
BackgroundA Fault-Tolerant Control Strategy for MMC with Smooth Clearance of Sub-Module Fault
Wang, M., Li, K., Sun, K., Liu, Z., & Sun, Y. F. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544532 · Cited by 8
“The selection of system parameters refers to [18-20], and the traditional nearest level modulation is adopted.”
BackgroundComparison of bipolar sub-modules for the alternate arm converter
Wickramasinghe, H. R., Konstantinou, G. S., Pou, J., Picas, R., Ceballos, S., & Agelidis, V. G. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793031 · Cited by 8
“Modularity, scalability, simplicity of submodule (SM) capacitor voltage balancing, and redundant configuration [4] are the salient features of the MMC, which provide near sinusoidal output voltages and currents with low harmonic distortion owing to the large number of voltage levels.”
BackgroundSelf-citationReconfigurability, Modularity and Redundancy Trade-offs for Grid Connected Power Electronic Systems
Ahmadi, M., Shekhar, A., & Bauer, P. (2022) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc51159.2022.9962889 · Cited by 8
A distributed PWM strategy for modular multilevel converter
Debnath, S., Qin, J., & Saeedifard, M. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048626 · Cited by 8
DC Voltage Control and OLTC Control Strategy for MMC-Based HVDC System Under SM Failure
Richa, A., Beig, A. R., & Jayashree, R. (2021) · IEEE Access · doi:10.1109/access.2021.3102377 · Cited by 8
Xiao, Q., Jin, Y., Wang, J., Wang, S., Chen, L., Jia, H., Mu, Y., Dragičević, T., & Teodorescu, R. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927316 · Cited by 8
“Therefore, redundancy SMs and fault-tolerant control are necessary for the safe and stable operation of MMC [10].”
BackgroundWang, C., Zeng, W., Wang, Y., Li, C., Duan, W., Yang, X., & Xie, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3216301 · Cited by 10
“Therefore, redundant cells can also sometimes be used to optimize the performance of converters [26], [27].”
BackgroundYang, J., Che, Y., Guo, X., Ran, L., & Chen, Y. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3380163 · Cited by 8
“Most high-power applications, such as modular multilevel converters (MMC), rely on redundancy technology to ensure their operational reliability [30].”
BackgroundKandasamy, K., Vilathgamuwa, D. M., & Tseng, K. J. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048935 · Cited by 7
Dynamic preventive maintenance strategy for MMC considering multi-term thermal cycles
Feng, F., Yu, J., Yang, Z., Dai, W., Zhao, X., Kamel, S. M., Wang, J., & Fu, G. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105560 · Cited by 8
Li, J., & Yin, J. (2019) · Energies · doi:10.3390/en12091726 · Cited by 7
Fault-tolerant operation scheme for modular multilevel converter under arm energy imbalance
Kang, J., Kim, H., Hur, K., Jung, H.-J., & Lee, D.-S. (2017) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2017.8289247 · Cited by 6
Reliability Analysis of Modular Multilevel Converters in MVDC Applications
Tian, Y., & Konstantinou, G. S. (2024) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2024.100671 · Cited by 9
Self-citationA Copula-Based k-out-of-n Reliability Modeling for MMC with Considering the Submodule Correlation
Xu, Q., Zhuang, Y., Li, Y., & Zheng, W. (2020) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees48850.2020.9121419 · Cited by 7
“[10], through the fault simulation of the SM, it can be seen that the faulty SMs will affect the capacitance voltage of the other SMs in the same arm, and the amplitude of the SM capacitance ripple will also change.”
Ahmad, A. B., & Ooi, C. A. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2956539 · Cited by 8
“In [22], an MMC with active redundant SMs was analyzed.”
MethodVarying and unequal carrier frequency PWM techniques for modular multilevel converters
Konstantinou, G. S., Darus, R., Pou, J., Ceballos, S., & Agelidis, V. G. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6870038 · Cited by 6
Self-citationKonstantinou, G. S., Pou, J., Darus, R., Ceballos, S., & Agelidis, V. G. (2015) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2015.7125549 · Cited by 5
“Additional functionality for the MMC can be achieved through operational redundancies [4], direct integration of energy storage elements [5] and numerous sub-module (SM) configurations [6] depending on the requirements of each application.”
BackgroundSelf-citationFault Tolerant Control for Medium Voltage Hybrid MMC With Cold Reserve Submodules
Hassanifar, M., Ventura, S., Langwasser, M., Amato, D. D., Monopoli, V. G., & Liserre, M. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667457 · Cited by 5
“However, this comes at the expense of higher losses [12].”
BackgroundSharifabadi, K., Harnefors, L., Nee, H., Norrga, S., & Teodorescu, R. (2016) · Wiley eBooks · doi:10.1002/9781118851555.ch2 · Cited by 8
Liang, G., Yadav, G. N. B., Rodríguez, E., Farivar, G. G., & Pou, J. (2022) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec55080.2022.10058368 · Cited by 6
“RSMs can be integrated into the CBESS as either active redundancy [8], [9] (also known as hot reserve) or inactive redundancy (also known as cold reserve) [10].”
BackgroundMethodSelf-citationLi, T., & Zhao, C. (2015) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2156 · Cited by 5
A start strategy for synchronized connection of MMCs to an AC system
Li, H., Liu, C., Li, G., Guo, Q., & Luo, H. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.01.016 · Cited by 5
Energy Balancing of the Alternate Arm Converter Under Parameter Variations
Wickramasinghe, H. R., Konstantinou, G. S., & Pou, J. (2018) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2018.8433658 · Cited by 5
“The unique features of the modular topologies are: i) modularity, ii) scalability, iii) relatively simple capacitor voltage balancing capability, iv) flexibility of expanding to wide power and voltage ratings, and v) redundant configuration [6].”
BackgroundSelf-citationKim, S., Lee, K., & Lee, J.-S. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722287 · Cited by 5
“Most proposed studies about the faulttolerance for half-bridge based MMC are based on using reserved SMs [8]-[11].”
BackgroundMutyala, S. N. V., Cvetkovic, I., DiMarino, C., & Boroyevich, D. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948089 · Cited by 5
“For better use of redundant SMs, hot storage redundancy is implemented in [5][6][7], whereby redundant SMs are also operated as regular working SMs by lowering SM capacitor voltages.”
MethodFault-Tolerant Operation Approach for Nested Neutral Point Clamp (NNPC) Converter
Barahouei, V., Barakati, S. M., Haredasht, M. R., Hashkavayi, M. B., & Jedi, M. Z. (2023) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc57673.2023.10087114 · Cited by 4
“In the software methods, the Fault-Tolerant process is associated with modifying the converter control process, which is a high computational burden [23].”
BackgroundMethodInfluential
Metadata
- Authors
- Konstantinou, G., Pou, J., Ceballos, S., & Agelidis, V. G.
- Affiliations
- UNSW Sydney (AU)
- Tecnalia (ES)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2013-10
- Volume
- 28
- Issue
- 4
- Pages
- 2333-2341
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W1995673130
- Cited by
- 152
- References
- 30
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 7 · 2023: 14 · 2022: 8 · 2021: 11 · 2020: 14 · 2019: 15 · 2018: 16 · 2017: 11 · 2016: 18 · 2015: 16 · 2014: 14
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (acceptedVersion, other-oa)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, active redundancy, switching frequency reduction, voltage dynamics, analytical model, single-phase converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.