Active Redundant Submodule Configuration in Modular Multilevel Converters
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The modular multilevel converter (MMC) is based on the cascaded connection of identical submodules (SMs) enabling additional redundancies. This paper proposes the configuration of the MMC topology with redundant SMs and demonstrates the effects of active redundancies. The proposed configuration decreases the switching frequency per SM while reducing the SM capacitor voltage ripples. An analytical model for determining the SM capacitor voltage ripple and voltage dynamics is derived. The results from the analytical model are compared with the switching model for a 21-level MMC with five redundant (25 in total) SMs per arm. Experimental results based on a single-phase laboratory prototype with five SMs per arm and a single redundant cell further illustrate the operation and verify the derived mathematical model and simulation results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“and lower switching frequency, resulting in more efficient operation of the overall conversion system [3].”
BackgroundSelf-citationAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 2×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundVSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“Multilevel converters are particularly suitable for high-power applications, such as high-voltage direct current (HVDC) transmission [1], static synchronous compensators”
BackgroundSelf-citationControl and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“A typical configuration of the MMC topology [4]–[10] requires SMs per arm of the converter in order to generate or voltage levels in the output, depending on the modulation strategy [15] or internal control requirements [19], [20].”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“The MMC is a member of the broad family of cascade multilevel converters [17] and features significant ad-”
BackgroundModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Gnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“as steady-state [24] and dynamic [25] analysis of the converter”
Background
Cited by
Items 101–159 of 159
Discontinuous modulation of modular multilevel converters without the need for extra submodules
Picas, R., Ceballos, S., Pou, J., Zaragoza, J., Konstantinou, G. S., Agelidis, V. G., & Balcells, J. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392484 · Cited by 4
“Moreover, the use of additional SMs in DPWM provides a further reduction in the capacitor voltage ripples [15].”
MethodSelf-citationA discrete time-domain model for fast simulation of MMC circuits
Zhang, F., Yang, X., Wang, K., Xu, G., Huang, L., & Chen, W. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512667 · Cited by 4
“It has significant advantages in reducing harmonic distortion of the waveforms, minimizing filtering requirements, and reducing switching losses [1], [2].”
BackgroundUtilising redundant voltage levels for circulating current control in modular multilevel converters
Konstantinou, G. S., Pou, J., Ceballos, S., Picas, R., Zaragoza, J., & Agelidis, V. G. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392430 · Cited by 4
“They offer an expandable and redundant configuration [5] capable of generating a high number of voltage levels and provide high quality voltages and currents with high efficiency and low switching losses [2], [3].”
BackgroundSelf-citationModelling of modular multilevel converter topology with voltage correcting modules
Riar, B., & Madawala, U. K. (2014) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2014.6878622 · Cited by 3
“Capacitor voltage variations and thus circulating currents in a phase-leg are reduced by increasing the number of modules but without increasing the number of voltage levels [7].”
BackgroundHassanifar, M., D’Amato, D., Langwasser, M., & Liserre, M. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3647886 · Cited by 3
“Redundant SMs can be classified into hot and cold reserve SMs. Hot reserve SMs are actively operating during the normal operation of the MMC, functioning alongside the other SMs [12].”
Synchronous Switching Scheme - Bringing Modular Fault Tolerance to Power Converters
Shirodkar, A. S., Banavath, S. N., Chub, A., Mandrioli, R., Ricco, M., & Vinnikov, D. (2026) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2026.3683136 · Cited by 3
“In previous literature, active redundancy in power converters has been proposed at the converter level and submodule level in multilevel inverters, as well as in interleaved inverters [20], [21], [26], but not at the individual switch level.”
Chen, X., Liu, J., Ouyang, S., & Song, S. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846003 · Cited by 3
New scheme of phase-shifted carrier PWM for modular multilevel converter with redundancy sub-modules
Choi, J., & Han, B.-M. (2015) · Australasian Universities Power Engineering Conference · doi:10.1109/aupec.2015.7324814 · Cited by 3
“N numbers of SMs engage in the DC voltage balancing and M numbers of SMs with the highest or lowest DC voltage remain in an OFF state and do not engage in switching [9][[10].”
BackgroundZhang, Y., Wang, H., Wang, Z., & Blaabjerg, F. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558180 · Cited by 3
“, redundancy [3] and fault protection control [4]) are proposed to improve the MMC’s reliability, these methods usually sacrifice some important characters, such as costs, footprint and power density.”
Loss distribution and characterization of MMC sub‐modules for HVDC applications
Tian, Y., Wickramasinghe, H. R., Pou, J., & Konstantinou, G. S. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.13042 · Cited by 6
Self-citationZhao, C., Li, Y., Li, Z., Xu, F., & Wang, P. (2016) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2016.7527048 · Cited by 2
“The analysis about reducing switching frequency and capacitor voltage fluctuations with redundant SMs is provided by [15] and [16].”
BackgroundActive Redundancy in Fault Tolerance: A Modular Switch Level Solution with Synchronous Switching
Shirodkar, A. S., Banavath, S. N., Chub, A., Mandrioli, R., & Ricco, M. (2025) · IEEE International Conference on DC Microgrids · doi:10.1109/icdcm63994.2025.11144667 · Cited by 2
“Here, the additional hardware contributes to the regular operation of the converter and, upon failure of any component, replaces the operation of the faulty component, thus allowing for uninterrupted operation of the power converter [16], [17].”
Dong, Y., Yang, H., Li, W., He, X., Zhou, Z., & Xie, R. J. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0592 · Cited by 2
Internal Faults in Modular Multilevel Converter
Kedia, S., Thute, R. S., Bahirat, H. J., & Shukla, A. (2018) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2018.8707827 · Cited by 2
Tian, Y., Wickramasinghe, H. R., Pou, J., & Konstantinou, G. S. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255315 · Cited by 2
“The sub-module based design offers a high-degree of system reliability [5] while the multilevel waveforms (e.”
BackgroundSelf-citationTesta, L., Kalmbach, O., & Hackl, C. M. (2023) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie51358.2023.10228050 · Cited by 2
“Furthermore, redundant concepts can be established to prevent system shutdowns and increase fault tolerance [6].”
BackgroundHamayoon, S., Hovd, M., & Suul, J. A. (2023) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie51358.2023.10228064 · Cited by 2
Active Redundancy in Isolated DC-DC Converters: A Modular Solution for Fault Tolerance
Shirodkar, A. S., Banavath, S. N., Yadav, N., Chub, A., & Mandrioli, R. (2025) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng63314.2025.11027280 · Cited by 2
“Active Redundancy based fault tolerance involves additional components which contribute during the normal operation of the power converter, and are responsible for the uninterrupted operation of the power converter in post fault conditions [15], [16].”
A New Harmonic Mitigation Scheme for MMC – An Experimental Approach
Madichetty, S., Dasgupta, A., & Jinka, S. (2014) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2014-0015 · Cited by 2
“This method is simple in design and can substantially eliminate the RMS value of the circulating current compared with the existing method [4], while the voltages of the SM capacitors are kept well balanced.”
BackgroundMethodInfluentialLiu, G., Zhou, Y., Xiao, H., & Xu, Z. G. (2016) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2016.7741128 · Cited by 2
A fixed topology Thévenin equivalent integral model for modular multilevel converters
Zhang, F., Yang, X., Huang, L., Wang, K., Xu, G., Li, Y., & Xie, R. (2017) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2496 · Cited by 2
Fault Tolerance in Multiple-Active Bridge Converters Applied in Smart Transformers
Ferreira, V. N., Buticchi, G., Cardoso, B. J., & Liserre, M. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915477 · Cited by 2
“tolerance capability in medium/high voltage (MV/HV) systems [7, 8, 9, 10, 11].”
BackgroundOperation of MMC Based Unipolar HVDC Under SM Failure
Richa, R., Beig, A. R., Dekka, A., & Jayashree, R. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927428 · Cited by 2
“Several works have reported the satisfactory performance and acceptable THD using PD-PWM [34], [35]–[37].”
BackgroundReducing Operational Costs of Offshore HVDC Energy Export Systems Through Optimized Maintenance
Unnewehr, J. F., Waldl, H. P., Pahlke, T., Herráez, I., & Weidlich, A. (2020) · Energies · doi:10.3390/en13051146 · Cited by 3
“If a failure occurs, the failed SM will be bypassed automatically [26].”
BackgroundCharging and discharging methods for modularized battery energy storage systems (MBESS)
Kandasamy, K. (2016) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/66669 · Cited by 2
Detection of Stealthy False Data Injection Attacks in Modular Multilevel Converters
Chen, X., & Song, S. (2023) · Energies · doi:10.3390/en16176353 · Cited by 1
“It should be noted that although there are N + M SMs in each arm, the maximum value of the arm-inserted SM number using NLM in one control cycle is N [28], because the active redundant mode [28] is applied in this paper.”
MethodShirodkar, A. S., Banavath, S. N., Mandrioli, R., Carne, G. D., & Sitbon, M. (2025) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon58223.2025.11221120 · Cited by 1
“…replicating vulnerable components in a power electronic converter which contribute to the normal operation of the power converter, and in the event of component failure, allow for uninterrupted operation of the converter with no major alterations to its operating principles [16], [17].”
A low-loss energy rebalancing control scheme of MMC under submodule fault conditions
Yang, L., Li, Y., Li, Z., Wang, P., & Xu, F. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216770 · Cited by 1
“Redundant SMs are set to improve the reliability and performance of MMC, which are divided into two kinds: the cold-reserve [7] and hot-reserve [8].”
BackgroundResearch on N-1 Uninterrupted Operation Method for MMC-based Shore Power Supply System
Wei, H., Cheng, Q., Zhang, H., Wang, H., Hou, K., & Wang, X. (2019) · IEEE International Conference on Automation, Electronics and Electrical Engineering (AUTEEE) · doi:10.1109/auteee48671.2019.9033154 · Cited by 1
Konstantinou, G. S., Wickramasinghe, H. R., & Zhang, X. (2019) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes47639.2019.9105422 · Cited by 1
Self-citationAn Optimal Preventive Maintenance Method for MMC based VSC-HVDC
Yuan, C., Dai, D., Qiu, J., Lü, C., Qu, H., & Cao, J. (2020) · International Conference on Smart Power & Internet Energy Systems (SPIES) · doi:10.1109/spies48661.2020.9242935 · Cited by 1
“INTRODUCTION At present, modular multi-level converter (MMC) is widely used in power system, especially in Voltage Source Converter based High Voltage Direct Current Transmission (VSC-HVDC)[1],[2], because it can work under high voltage and current; it has modular structure and it’s easy to maintain [3], [4].”
MethodA Condition-Based-Maintenance Model of MMC Considering Perfect Replacement
Yuan, C., Dai, D., Qiu, J., Lü, C., Qu, H., & Cao, J. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9368058 · Cited by 1
“INTRODUCTION Nowadays, modular multi-level converter (MMC) is widely used in power system, especially in high-voltage direct current (HVDC), because it can work under high voltage and current; the structure of it is modular and the maintenance strategy of it is easy[1], [2].”
BackgroundDetection and isolation of abnormal sub-module in an offshore MMC-HVDC system
Bapiraju, J. V. V. N., & Manohar, P. (2021) · Electrical Engineering · doi:10.1007/s00202-021-01421-3 · Cited by 1
Tian, Y., & Konstantinou, G. S. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213759 · Cited by 2
“In order to improve the reliability in MMC, redundant design with additional SMs in an arm has been proposed in the literature [7].”
Self-citationModified Sorting Algorithm for Fault- Tolerant Operation of Hybrid MMC With Hot Reserve Submodules
Hassanifar, M., Ventura, S., Langwasser, M., D’Amato, D., Monopoli, V. G., & Liserre, M. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667398 · Cited by 1
“Although the hot reserve SMs increase the overall losses of the converter they are helpful in reducing the capacitor ripple and decreasing the switching frequency of individual SM, which are significant factors in the lifetime and thermal stress of the components [17].”
BackgroundControl and modulation of modular multilevel converters
Picas, R. (2016) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-106490 · Cited by 1
“In this thesis the technique of active redundant SMs is used [64,123], which gives the same consideration to all the SMs, but in normal operation the maximum number of SMs activated in each arm is N out of the N+M available.”
BackgroundMethodCommande décentralisée et modulaire des convertisseurs MMC intégrée au coeur des gate-drivers
Darbas, C. (2022) · theses.fr (ABES) · doi:10.70675/dd04435aze64bz4676z8912z9893c6183fff · Cited by 1
DC fault ride through operation of a full-bridge MMC converter
Feng, Y. (2016) · Nottingham ePrints (University of Nottingham)
Tan, F., Chen, H., Zhang, Z., Li, Y., Zhu, C., & Gao, S. (2018) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2018.8582212
“Flexible alternating current transmission systems is a new technology for integrated power transmission, microelectronics, communication technology and control technology to achieve AC transmission control, which can enhance the stability of the AC grid and reduce transmission costs[4-6].”
BackgroundAnalysis of the AC Side of Modular Multilevel Converters Under Asymmetric Arm Impedance Conditions
Wu, X., Zheng, W., Qi, P., Zhou, T., & Nie, J. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-981-13-9779-0_45
Liu, R., Li, X., Hu, B., Ke, Z., Pan, J., Xu, L., Zhang, J., & Wang, J. (2021) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc47953.2021.9449540
“The existing solution is to add a redundant SM in each arm [2, 8, 10], and it operates under spinning SM reserve mode[3].”
MethodA Fault-Tolerant Approach for Hybrid Modular Multilevel Converter Using Negative Voltage Levels
Farzamkia, S., Sadigh, A. K., & Dargahi, V. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487238
“Reference [22] has utilized the RSMs in normal condition as well.”
MethodInherently Resilient Power Electronic Systems
Kaboli, S., Peyghami, S., & Blaabjerg, F. (2022) · Wiley eBooks · doi:10.1002/9781119772217.ch15
Bridge-Cell Modular-Multilevel-Cascade-ConvertersPreprint
Testa, L., Kalmbach, O., & Hackl, C. M. (2023) · doi:10.36227/techrxiv.22014884.v1
Fault-Tolerant Configuration for T-Type Nested Neutral Point Clamped (T-NNPC) Converter
Haredasht, M. R., & Barakati, S. M. (2023) · International Conference on Protection and Automation of Power Systems (IPAPS) · doi:10.1109/ipaps58344.2023.10123308
“As a result, these methods are associated with an increase in switching losses [23].”
BackgroundRojas, F., Jerez, C., Hackl, C. M., Kalmbach, O., Pereda, J. E., & Lillo, J. (2023) · doi:10.36227/techrxiv.23799792.v1
Reliability Modelling of Series Modular Multilevel Converters for MVDC Applications
Tian, Y., & Konstantinou, G. S. (2023) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg56097.2023.10215188 · Cited by 1
“For an MMC arm that includes N required SMs and M redundant SMs [19] with identical BFR, the k-out-of-n model is a basic approach that has been widely utilized in the evaluation of arm reliability [17].”
MethodSelf-citationArm Reliability in Modular Multilevel Converters for Mvdc ApplicationsPreprint
Tian, Y., & Konstantinou, G. S. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4614364
Self-citationReliability of Modular Multilevel Converters Considering Physics of Failure in MVDC Applications
Tian, Y., & Konstantinou, G. S. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567185
“This can be expressed as follows: In terms of an MMC arm, encompassing required and redundant SMs, operational functionality of at least the number of required SMs is necessary to ensure the rated performance of the entire arm [23].”
BackgroundSelf-citationResearch on Redundant Control Technology of ±10kV/10MW AC/DC converter
Tian, A., Jiayuan, M., Wang, J. H., Sun, G., & Lu, W. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567757
“In the AC/DC hybrid distribution network, a large number of distributed power sources are connected, which will bring fundamental changes to the distribution system [1].”
BackgroundMulti-channel adaptive median signal filter
Akhtyrskiy, K. A., Kabirov, V. A., Semenov, V. D., & Torgaeva, D. S. (2025) · iPolytech Journal · doi:10.21285/1814-3520-2024-4-504-520
Kalmbach, O., & Hackl, C. M. (2026) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2026.3673007
“Furthermore, redundant concepts can be established to prevent system shutdowns and increase fault tolerance [14].”
Athwer, A., Badawy, A., & Ma, X. (2026) · Lancaster EPrints (Lancaster University) · Cited by 1
Park, J., Park, K., Kim, H. J., Lee, S., Kim, J., Yu, S., Kim, D. L., Nam, T.-S., & Shim, J. W. (2026) · IEEE Access · doi:10.1109/access.2026.3680010
Condition and Health Monitoring of Modular Multilevel Converter for HVDC grids
Velazco, D. (2023) · theses.fr (ABES) · doi:10.70675/cdcd607fz268cz443bz8daazefedc0f8f044
Articles indexats publicats per investigadors del Campus de Terrassa: 2014
Biblioteca, U. P. D. C. C. D. T. (2015) · RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Anguru, D. D., Vempali, B. N. S. S., Ronanki, D., & Srinivas, S. (2026) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet69291.2026.11686943
“In HoRR-based FTC, all SMs, including the redundant SMs, actively participate during normal operation [18].”
Notched Switching - Fault Tolerance for Power Converters Utilising Parallel Switches
Shirodkar, A. S., Banavath, S. N., Thamballa, S., Carvalho, E. L., & Carne, G. D. (2026) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc69244.2026.11726109
“Active redundancy replicates critical components that are operational during normal operation of the power converter and bypasses the affected component during post-fault operation of the converter [13], [14].”
Metadata
- Authors
- Konstantinou, G., Pou, J., Ceballos, S., & Agelidis, V. G.
- Affiliations
- UNSW Sydney (AU)
- Tecnalia (ES)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2013-10
- Volume
- 28
- Issue
- 4
- Pages
- 2333-2341
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W1995673130
- Cited by
- 152
- References
- 30
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 7 · 2023: 14 · 2022: 8 · 2021: 11 · 2020: 14 · 2019: 15 · 2018: 16 · 2017: 11 · 2016: 18 · 2015: 16 · 2014: 14
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (acceptedVersion, other-oa)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, active redundancy, switching frequency reduction, voltage dynamics, analytical model, single-phase converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.