The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
DC Ring-Bus Microgrid Fault Protection and Identification of Fault Location
Abstract
A fault protection and location method for a dc bus microgrid system is presented in this paper. Unlike traditional ac systems, dc bus systems cannot survive or sustain high-magnitude fault currents. And if a fault causes the dc bus to de-energize completely, it makes locating faults very difficult. The main goal of the proposed scheme is to detect and isolate faults in the dc bus without de-energizing the entire system and identifying the fault location. In order to achieve this, a ring-type bus was used in this paper. The bus was segmented into overlapping nodes and links with circuit breakers (CBs) to isolate the segment in the event of a fault. Backup protection is implemented for circuit breaker failures to improve system reliability. A noniterative fault-location technique using a probe power is also presented in this paper. This probe power can also be used for a pilot test before main CB reclosing to avoid system issues that can be expected when the reclosing fails due to a permanent fault. The proposed algorithm can be implemented and executed by an intelligent electrical device for individual node. The proposed concepts have been verified with computer simulations and hardware experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Grainger, J. J., & Stevenson, W. D. (1994) · CERN Document Server (European Organization for Nuclear Research) · Cited by 747
Protection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635 · cited 1×
“Fault location can be determined using the computed reactance based on recorded fault current and voltage information at one terminal of a line [22], [23].”
BackgroundDC microgrid based distribution power generation system
Ito, Y., Yang, Z., & Akagi, H. (2004) · International Power Electronics and Motion Control Conference · Cited by 383
Fault Detection and Isolation in Low-Voltage DC-Bus Microgrid System
Park, J.-D., & Candelaria, J. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2243478 · Cited by 303
Self-citationThe Status of DC Micro-Grid Protection
Cuzner, R. M., & Venkataramanan, G. (2008) · 2008 IEEE Industry Applications Society Annual Meeting · doi:10.1109/08ias.2008.382 · Cited by 263
VSC-HVDC system protection: A review of current methods
Candelaria, J., & Park, J.-D. (2011) · 2011 IEEE/PES Power Systems Conference and Exposition · doi:10.1109/psce.2011.5772604 · Cited by 206
Self-citationDC power systems: Challenges and opportunities
Saeedifard, M., Graovac, M., Dias, R. F., & Iravani, R. (2010) · IEEE PES General Meeting · doi:10.1109/pes.2010.5589736 · Cited by 170
Protection of VSC-multi-terminal HVDC against DC faults
Tang, L., & Ooi, B.-T. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022539 · Cited by 161
Improved Fault Location on Distribution Feeders Based on Matching During-Fault Voltage Sags
Pereira, R. A. F., da Silva, L. G. W., Kezunovic, M., & Mantovani, J. R. S. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014480 · Cited by 159
A novel hybrid current-limiting circuit breaker for medium voltage: principle and test results
Steurer, M. M., Fröhlich, K., Holaus, W., & Kaltenegger, K. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.809614 · Cited by 145
Grounding of AC and DC low-voltage and medium-voltage drive systems
Das, J. C., & Osman, R. H. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.658747 · Cited by 120
A Novel Hybrid Current-Limiting Circuit Breaker for Medium Voltage: Principle and Test Results
Steurer, M. M., Frolich, K., Holaus, W., & Kaltenegger, K. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4311850 · Cited by 108
Apostolopoulos, C. A., & Korres, G. N. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2053223 · Cited by 86
Characteristics and Recovery Performance of VSC-HVDC DC Transmission Line Fault
Yang, J., Zheng, J., Tang, G., & He, Z. (2010) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2010.5449063 · Cited by 60
ANN-based fault classification and location in MVDC shipboard power systems
Chanda, N. K., & Fu, Y. M. (2011) · North American Power Symposium (NAPS) · doi:10.1109/naps.2011.6025172 · Cited by 60
Wavelet based method for fault detection in Medium Voltage DC shipboard power systems
Li, W., Luo, M., Monti, A., & Ponci, F. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229382 · Cited by 47
LVDC distribution system protection — Solutions, implementation and measurements
Salonen, P., Nuutinen, P., Peltoniemi, P., & Partanen, J. (2009) · European Conference on Power Electronics and Applications · Cited by 39
Taylor, F. (2000) · CRC Press eBooks · doi:10.1201/9780203908587.ch3.3 · Cited by 39
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
Review on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Dhar, S., Patnaik, R. K., & Dash, P. K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2654267 · Cited by 380
Metadata
- Authors
- Park, J.-D., Candelaria, J., Ma, L., & Dunn, K.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2013-10
- Volume
- 28
- Issue
- 4
- Pages
- 2574-2584
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2069032722
- Cited by
- 411
- References
- 21
- FWCI
- 21.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.