Unified Tuning of PID Load Frequency Controller for Power Systems via IMC
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
A unified PID tuning method for load frequency control (LFC) of power systems is discussed in this paper. The tuning method is based on the two-degree-of-freedom (TDF) internal model control (IMC) design method and a PID approximation procedure. The time-domain performance and robustness of the resulting PID controller is related to two tuning parameters, and robust tuning of the two parameters is discussed. The method is applicable to power systems with non-reheated, reheated, and hydro turbines. Simulation results show that it can indeed improve the damping of the power systems. It is shown that the method can also be used in decentralized PID tuning for multi-area power systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Zhou, K. (1998) · Cited by 3,824
Virk, G. S. (1990) · Chemical Engineering Science · doi:10.1016/0009-2509(90)85041-b · Cited by 3,216
Morari, M., & Zafiriou, E. (1988) · International Linear Collider · Cited by 2,735
The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory
Fosha, C., & Elgerd, O. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292603 · Cited by 693
Load frequency control strategies: A state-of-the-art survey for the researcher
Shayeghi, H., Shayanfar, H. A., & Jalili, A. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.09.014 · Cited by 550
Adaptive fuzzy gain scheduling for load frequency control
Talaq, J., & Al-Basri, F. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.744505 · Cited by 370
An adaptive controller for power system load-frequency control
Pan, C.-T., & Liaw, C.-M. (1989) · IEEE Transactions on Power Systems · doi:10.1109/59.32469 · Cited by 367
Application of Linear Matrix Inequalities for Load Frequency Control With Communication Delays
Yu, X., & Tomsovic, K. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831670 · Cited by 333
Techniques of model-based control
Brosilow, C. B., & Joseph, B. (2002) · Prentice Hall PTR eBooks · Cited by 317
Cited by
Delay-Dependent Stability for Load Frequency Control With Constant and Time-Varying Delays
Jiang, L., Yao, W., Wu, Q. H., Wen, J. Y., & Cheng, S. J. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2172821 · Cited by 604
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Yan, Z., & Xu, Y. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2999890 · Cited by 398
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
“In addition, the two-degree-of-freedom internal model control method for tuning the PID controller is discussed in [81,269] for load frequency control in conventional environments.”
BackgroundMethodSahu, R. K., Panda, S., & Rout, U. K. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.12.009 · Cited by 343
Decentralized Sliding Mode Load Frequency Control for Multi-Area Power Systems
Mi, Y., Fu, Y., Wang, C., & Wang, P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2277131 · Cited by 337
Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach
Yousef, H. A., AL-Kharusi, K., Albadi, M. H., & Hosseinzadeh, N. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2297432 · Cited by 314
Robust Load Frequency Control for Power System Considering Transmission Delay and Sampling Period
Shangguan, X.-C., Zhang, C.-K., He, Y., Jin, L., Jiang, L., Spencer, J. W., & Wu, M. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3026336 · Cited by 299
Fractional order PID controller for load frequency control
Sondhi, S., & Hote, Y. V. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.091 · Cited by 281
Xu, D., Liu, J., Yan, X.-G., & Yan, W. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2767544 · Cited by 202
“For the LFC in a power system, the conventional proportionalintegral-derivative (PID) controller is a popular control method widely used in engineering practice, because of the advantages of the simple and convenient structure, with no need for detailed information about the system dynamics [38].”
A new control scheme for PID load frequency controller of single-area and multi-area power systems
Padhan, D. G., & Majhi, S. (2013) · ISA Transactions · doi:10.1016/j.isatra.2012.10.003 · Cited by 202
“0 2 4 6 8 10 12 14 16 18 20 −18 −16 −14 −12 −10 −8 −6 −4 −2 0 2 x 10 −3 time in sec Δ f (H z) Proposed (Nominal) Tan (Nominal) Proposed (+ 50% Variation in KP, TP, TT, TG ) Tan (+ 50% Variation in KP, TP, TT, TG) Fig.”
BackgroundInfluentialLatif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114858 · Cited by 183
Metadata
- Authors
- Tan, W.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-02
- Volume
- 25
- Issue
- 1
- Pages
- 341-350
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2109631216
- Cited by
- 526
- References
- 20
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.