The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
Open accessAbstract
This paper presents a damping control to mitigate sub-synchronous interactions (SSI) in doubly-fed induction generator (DFIG) wind turbines connected to series-compensated lines. This issue has gained attention due to the recent SSI phenomena reported in DFIG wind farms located near series capacitors. Two approaches which add a supplementary damping control signal are compared: one of them, integrated to the grid-side converter, and the other one, to the rotor-side converter. The SSI damping controls are designed using a multi-input multi-output state-space methodology. This allows to easily tune a high performance controller using several measurements and control inputs. Small- and large-signal stability analyses, robustness aspects, impact of the supplementary controls on the system modes, and influence of different operating conditions on the SSI are also discussed. The obtained results show that the supplementary control is able to properly damp the sub-synchronous oscillations of DFIG wind turbines by updating the existing DFIG control systems without the inclusion of expensive additional damping devices, and reducing the risk of wind generation tripping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Pena, R., Clare, J. C., & Asher, G. M. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960288 · Cited by 2,759
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
General model for representing variable speed wind turbines in power system dynamics simulations
Slootweg, J. G., de Haan, S. W. H., Polinder, H., & Kling, W. L. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2002.807113 · Cited by 963
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
A new mathematical model and control of a three-phase AC-DC voltage source converter
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554176 · Cited by 871
Modeling and control of a wind turbine driven doubly fed induction generator
Tapia, A., Tapia, G., Ostolaza, J. X., & Saenz, J. R. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811727 · Cited by 811
A Schur method for balanced-truncation model reduction
Safonov, M. G., & Chiang, R. Y. (1989) · IEEE Transactions on Automatic Control · doi:10.1109/9.29399 · Cited by 600
Modeling of DFIG-Based Wind Farms for SSR Analysis
Fan, L., Kavasseri, R., Miao, Z. L., & Zhu, C. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050912 · Cited by 472
Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network
Miao, Z. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2012.2211019 · Cited by 329
Reader's guide to subsynchronous resonance
(1992) · IEEE Transactions on Power Systems · doi:10.1109/59.141698 · Cited by 283
ERCOT experience with Sub-synchronous Control Interaction and proposed remediation
Adams, J., Carter, C., & Huang, S.-H. (2012) · PES T&D 2012 · doi:10.1109/tdc.2012.6281678 · Cited by 281
Ostadi, A., Yazdani, A., & Varma, R. K. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2013667 · Cited by 208
A Procedure to Study Sub-Synchronous Interactions in Wind Integrated Power Systems
Suriyaarachchi, D. H. R., Annakkage, U. D., Karawita, C., & Jacobson, D. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2204283 · Cited by 135
Integration of large wind farms into utility grids (part 2 - performance issues)
Pourbeik, P., Koessler, R. J., Dickmander, D. L., & Wong, W. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2003.1267381 · Cited by 93
New microprocessor based relay to monitor and protect power systems against sub-harmonics
Narendra, K. G., Fedirchuk, D. J., Midence, R., Zhang, N., Mulawarman, A., Mysore, P., & Sood, V. K. (2011) · IEEE Electrical Power and Energy Conference (EPEC) · doi:10.1109/epec.2011.6070241 · Cited by 90
León, A. E., Farias, M. F., Battaiotto, P. E., Solsona, J. A., & Valla, M. I. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2088141 · Cited by 88
Self-citationReactance Scan Crossover-Based Approach for Investigating SSCI Concerns for DFIG-Based Wind Turbines
Cheng, Y., Sahni, M., Muthumuni, D., & Badrzadeh, B. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2223239 · Cited by 80
Wind generators and series-compensated AC transmission lines
Larsen, E. V. (2012) · doi:10.1109/tdc.2012.6281548 · Cited by 26
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
“the first time in the field in the Electric Reliability Council of Texas (ERCOT) in 2009 [49], [55]–[57].”
BackgroundSubsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks
Liu, H., Xie, X., He, J., Xu, T., Yu, Z., Wang, C., & Zhang, C. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2682197 · Cited by 623
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Xie, X., Zhang, X., Liu, H., Liu, H., Li, Y., & Zhang, C. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2676024 · Cited by 381
Liu, H., Xie, X., Zhang, C., Li, Y., Liu, H., & Hu, Y. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2558840 · Cited by 327
Metadata
- Authors
- Leon, A. E., & Solsona, J. A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 419-428
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2325009693
- Cited by
- 316
- References
- 21
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.