Real-Time Faulted Line Localization and PMU Placement in Power Systems Through Convolutional Neural Networks
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Diverse fault types, fast reclosures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as static loads, or require much higher sampling rates or total measurement availability. This paper proposes a faulted line localization method based on a convolutional neural network (CNN) classifier using bus voltages. Unlike prior data-driven methods, the proposed classifier is based on features with physical interpretations that improve the robustness of the location performance. The accuracy of our CNN-based localization tool is demonstrably superior to other machine learning classifiers in the literature. To further improve the location performance, a joint phasor measurement units placement strategy are proposed and validated against other methods. A significant aspect of our methodology is that under very low observability (7% of buses), the algorithm is still able to localize the faulted line to a small neighborhood with high probability. The performance of our scheme is validated through simulations of faults of various types in the IEEE 39-bus and 68-bus power systems under varying uncertain conditions, system observability, and measurement quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155 · cited 4×
“ones with millions of parameters [15], [16].”
BackgroundMethodInfluentialAdam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946 · cited 2×
“The RMSprop optimizer with decay coefficient α = 0.9 is employed to train the CNN after comparing with Adam and stochastic gradient descent methods.”
MethodInfluentialPower System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Sequence to Sequence Learning with Neural Networks
Sutskever, I., Vinyals, O., & Le, Q. V. (2014) · arXiv · doi:10.48550/arxiv.1409.3215 · Cited by 17,766 · cited 3×
“ones with millions of parameters [15], [16].”
BackgroundMethodPractical Recommendations for Gradient-Based Training of Deep Architectures
Bengio, Y. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_26 · Cited by 2,259 · cited 3×
“For example, “early stopping” is a convergence criterion to avoid over-fitting, and “batch normalization” is effective to the issue of covariance shift [26].”
BackgroundMethodUnderstanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791 · cited 1×
“This phenomenon is due to the different ratio of reactance X to impedance R between the source and the feeder [38].”
BackgroundAcoustic Modeling Using Deep Belief Networks
Mohamed, A.-R., Dahl, G. E., & Hinton, G. (2012) · IEEE Transactions on Audio, Speech, and Language Processing · doi:10.1109/tasl.2011.2109382 · Cited by 1,727 · cited 1×
“[16] and speech recognition [21], through the selection of correct data-features.”
BackgroundUnderstanding Power Quality Problems, Voltage Sags and Interruptions
Bollen, M. (2000) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,159
Low-Shot Visual Recognition by Shrinking and Hallucinating Features
Hariharan, B., & Girshick, R. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.328 · Cited by 792 · cited 2×
“12 buses selected by the Random algorithm include SR = [31, 3, 65, 46, 43, 28, 15, 44, 23, 58, 9, 57], one solution of the 2hop VC algorithm is obtained by solving a linear programming approximating the 2-hop VC formulation, and the selected buses are SV C = [3, 6, 13, 19, 23, 26, 30, 31, 36, 40, 44, 52], and the 12 b…”
BackgroundMethodA toolbox for power system dynamics and control engineering education and research
Chow, J. H., & Cheung, K. W. (1992) · IEEE Transactions on Power Systems · doi:10.1109/59.207380 · Cited by 531 · cited 3×
“3) Numerical Example: We simulate in the power system toolbox (PST), based on nonlinear models [20], a three-phase short circuit fault lasting 0.2 seconds at the line 5-6 in the IEEE 68-bus power system.”
MethodInfluential
Cited by
Machlev, R., Heistrene, L., Perl, M., Levy, K. Y., Belikov, J., Mannor, S., & Levron, Y. (2022) · Energy and AI · doi:10.1016/j.egyai.2022.100169 · Cited by 552
Wu, Y., Sicard, B., & Gadsden, S. A. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124678 · Cited by 357
EDLA-EFDS: A Novel Ensemble Deep Learning Approach For Electrical Fault Detection Systems
Elmasry, W., & Wadi, M. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.107834 · Cited by 42
Metadata
- Authors
- Li, W., Deka, D., Chertkov, M., & Wang, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-11
- Volume
- 34
- Issue
- 6
- Pages
- 4640-4651
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2981344804
- Cited by
- 183
- References
- 26
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Faulted Line Localization and PMU Placement in Power Systems Through Convolutional Neural Networks. https://app.cochat.ai/papers/10.1109/tpwrs.2019.2917794
- The paper
- Li, W., Deka, D., Chertkov, M., & Wang, M. (2019). Real-Time Faulted Line Localization and PMU Placement in Power Systems Through Convolutional Neural Networks. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2019.2917794
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.