Diverse fault types, fast reclosures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as static loads, or require much higher sampling rates or total measurement availability. This paper proposes a faulted line localization method based on a convolutional neural network (CNN) classifier using bus voltages. Unlike prior data-driven methods, the proposed classifier is based on features with physical interpretations that improve the robustness of the location performance. The accuracy of our CNN-based localization tool is demonstrably superior to other machine learning classifiers in the literature. To further improve the location performance, a joint phasor measurement units placement strategy are proposed and validated against other methods. A significant aspect of our methodology is that under very low observability (7% of buses), the algorithm is still able to localize the faulted line to a small neighborhood with high probability. The performance of our scheme is validated through simulations of faults of various types in the IEEE 39-bus and 68-bus power systems under varying uncertain conditions, system observability, and measurement quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155 · cited 4×
“ones with millions of parameters [15], [16].”
BackgroundMethodInfluentialAdam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946 · cited 2×
“The RMSprop optimizer with decay coefficient α = 0.9 is employed to train the CNN after comparing with Adam and stochastic gradient descent methods.”
MethodInfluentialPower System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Sequence to Sequence Learning with Neural Networks
Sutskever, I., Vinyals, O., & Le, Q. V. (2014) · arXiv · doi:10.48550/arxiv.1409.3215 · Cited by 17,766 · cited 3×
“ones with millions of parameters [15], [16].”
BackgroundMethodPractical Recommendations for Gradient-Based Training of Deep Architectures
Bengio, Y. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_26 · Cited by 2,259 · cited 3×
“For example, “early stopping” is a convergence criterion to avoid over-fitting, and “batch normalization” is effective to the issue of covariance shift [26].”
BackgroundMethodUnderstanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791 · cited 1×
“This phenomenon is due to the different ratio of reactance X to impedance R between the source and the feeder [38].”
BackgroundAcoustic Modeling Using Deep Belief Networks
Mohamed, A.-R., Dahl, G. E., & Hinton, G. (2012) · IEEE Transactions on Audio, Speech, and Language Processing · doi:10.1109/tasl.2011.2109382 · Cited by 1,727 · cited 1×
“[16] and speech recognition [21], through the selection of correct data-features.”
BackgroundUnderstanding Power Quality Problems, Voltage Sags and Interruptions
Bollen, M. (2000) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,159
Low-Shot Visual Recognition by Shrinking and Hallucinating Features
Hariharan, B., & Girshick, R. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.328 · Cited by 792 · cited 2×
“12 buses selected by the Random algorithm include SR = [31, 3, 65, 46, 43, 28, 15, 44, 23, 58, 9, 57], one solution of the 2hop VC algorithm is obtained by solving a linear programming approximating the 2-hop VC formulation, and the selected buses are SV C = [3, 6, 13, 19, 23, 26, 30, 31, 36, 40, 44, 52], and the 12 b…”
BackgroundMethodA toolbox for power system dynamics and control engineering education and research
Chow, J. H., & Cheung, K. W. (1992) · IEEE Transactions on Power Systems · doi:10.1109/59.207380 · Cited by 531 · cited 3×
“3) Numerical Example: We simulate in the power system toolbox (PST), based on nonlinear models [20], a three-phase short circuit fault lasting 0.2 seconds at the line 5-6 in the IEEE 68-bus power system.”
MethodInfluentialMachine Learning, a Probabilistic Perspective
Robert, C. (2014) · CHANCE · doi:10.1080/09332480.2014.914768 · Cited by 337
Dimensionality Reduction of Synchrophasor Data for Early Event Detection: Linearized Analysis
Xie, L., Chen, Y., & Kumar, P. R. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2316476 · Cited by 266 · cited 2×
“Assuming that fault detection through known techniques [17] is successful, we are interested in real-time localization of the faulted line using PMU measure-”
MethodCharacterizing and quantifying noise in PMU data
Brown, M., Biswal, M., Brahma, S., Ranade, S. J., & Cao, H. (2016) · 2016 IEEE Power and Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2016.7741972 · Cited by 251 · cited 1×
“We select the experimental range of SNR from 40 dB to 100 dB [17], [35], [36].”
MethodSparse Overcomplete Representations for Efficient Identification of Power Line Outages
Zhu, H., & Giannakis, G. B. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2192142 · Cited by 203 · cited 1×
“It is worth mentioning that a parallel line of work on line outage localization for state estimation or topology estimation [14] based on direct current (DC) power flow models exist.”
BackgroundKorkali, M., Lev-Ari, H., & Abur, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2176351 · Cited by 189
Jiang, H., Zhang, J. J., Gao, W., & Wu, Z. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2330624 · Cited by 172
Locating the Source of Events in Power Distribution Systems Using Micro-PMU Data
Farajollahi, M., Shahsavari, A., Stewart, E., & Mohsenian‐Rad, H. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2832126 · Cited by 168 · cited 1×
“dance-based method computes the fault currents according to the measured voltages and known bus impedance and then determines the fault distance to the measured point using distributed parameters [3]–[5]. Such methods assume static loads and are sensitive to the values of line parameters. Traveling-wave based approach…”
MethodYadav, A., & Swetapadma, A. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.079 · Cited by 86 · cited 2×
“be pre-processed through Fourier or wavelet transformation, and the coefficients or fundamental components of the transformed data are treated as features [8], [9].”
MethodFault Location Using Wide-Area Measurements and Sparse Estimation
Feng, G., & Abur, A. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2469606 · Cited by 75 · cited 1×
“The authors in [11], [12] largely reduce the computational complexity by formulating the search process into a sparse optimization problem, and the values larger than a pre-defined threshold indicate the faulted area.”
BackgroundA Straightforward Method for Wide-Area Fault Location on Transmission Networks
Azizi, S., & Sanaye‐Pasand, M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2334471 · Cited by 71 · cited 2×
“For the wide-area methods, the faulted line is first localized (either exactly or approximately), and then the exact position along the line is determined at a second stage [10]–[13].”
MethodA Sparse-Data-Driven Approach for Fault Location in Transmission Networks
Majidi, M., Etezadi-Amoli, M., & Fadali, M. S. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2493545 · Cited by 69 · cited 2×
“, [12], [27], are devised to guarantee full system observability.”
BackgroundAn Efficient PMU-Based Fault-Location Technique for Multiterminal Transmission Lines
Jiang, Q., Wang, B., & Li, X. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2298865 · Cited by 66 · cited 1×
“In the case of a n-bus power system without un-transposed lines1, we apply the substitution theory [18] to derive the equations related to pre and during-fault system variables.”
MethodOn PMU location selection for line outage detection in wide-area transmission networks
Zhao, Y. Z., Goldsmith, A. J., & Poor, H. V. (2012) · IEEE Power and Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2012.6344572 · Cited by 49
Coupling pairwise support vector machines for fault classification
Pöyhönen, S., Arkkio, A., Jover, P., & Hyötyniemi, H. (2004) · Control Engineering Practice · doi:10.1016/j.conengprac.2004.08.002 · Cited by 48
Li, W., Wang, M., & Chow, J. H. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2796442 · Cited by 46 · cited 2×
“12 buses selected by the Random algorithm include SR = [31, 3, 65, 46, 43, 28, 15, 44, 23, 58, 9, 57], one solution of the 2hop VC algorithm is obtained by solving a linear programming approximating the 2-hop VC formulation, and the selected buses are SV C = [3, 6, 13, 19, 23, 26, 30, 31, 36, 40, 44, 52], and the 12 b…”
MethodSelf-citationLine Outage Localization Using Phasor Measurement Data in Transient State
Garcia, M., Catanach, T., Wiel, S. V., Bent, R. W., & Lawrence, E. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2461461 · Cited by 33 · cited 1×
“The number of classes m = 47, including 46 locations of the faulted line and one null outage line [29].”
Background
Cited by
Machlev, R., Heistrene, L., Perl, M., Levy, K. Y., Belikov, J., Mannor, S., & Levron, Y. (2022) · Energy and AI · doi:10.1016/j.egyai.2022.100169 · Cited by 552
Wu, Y., Sicard, B., & Gadsden, S. A. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124678 · Cited by 357
EDLA-EFDS: A Novel Ensemble Deep Learning Approach For Electrical Fault Detection Systems
Elmasry, W., & Wadi, M. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.107834 · Cited by 42
Metadata
- Authors
- Li, W., Deka, D., Chertkov, M., & Wang, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-11
- Volume
- 34
- Issue
- 6
- Pages
- 4640-4651
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2981344804
- Cited by
- 183
- References
- 26
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.