Definition and Classification of Power System Stability – Revisited & Extended
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Since the publication of the original paper on power system stability definitions in 2004, the dynamic behavior of power systems has gradually changed due to the increasing penetration of converter interfaced generation technologies, loads, and transmission devices. In recognition of this change, a Task Force was established in 2016 to re-examine and extend, where appropriate, the classic definitions and classifications of the basic stability terms to incorporate the effects of fast-response power electronic devices. This paper based on an IEEE PES report summarizes the major results of the work of the Task Force and presents extended definitions and classification of power system stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“AI approaches, which mimic human thought, may be helpful [87]: they mentioned in their study that recent developments include using ANN to maintain steady-state security and FL applications for determining the reliability of power systems using the interrupted energy assessment rate given in [88].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [87]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Self-citationGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 1×
“The vast majority of large-scale CIGs use voltage-source converters [11], [12], or some derivative thereof, allowing designs that offer full four-quadrant control.”
BackgroundDesign and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402 · cited 1×
“The resonance of an inverter filter can also be triggered by the control of the inverter itself or by interactions with nearby controllers [76].”
BackgroundVoltage‐Sourced Converters in Power Systems: Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Wiley eBooks · doi:10.1002/9780470551578 · Cited by 2,264
Voltage Stability of Electric Power Systems
Cutsem, T., & Vournas, C. (1998) · Springer eBooks · doi:10.1007/978-0-387-75536-6 · Cited by 2,036
Self-citationKroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367 · cited 1×
“5) Converter-driven Stability: The dynamic behavior of CIG is clearly different from conventional synchronous generators, due to the predominant VSC interface with the grid [70].”
BackgroundHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 1×
“the electromagnetic transients of the network, which may lead to unstable power system oscillations over a wide frequency range [71].”
BackgroundWind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Research works printed but not linked: 11
- P. Pourbeik and J. K. Petter, "Modeling and validation of battery energy storage systems using simple generic models for power system stability studies," Cigre Sci. Eng., no. 9, pp. 63-72, Oct. 2017.
- Dynamic Models for Turbine-Governors in Power System Studies, IEEE Power and Energy Society, Tech. Rep. PES -TR1, Jan. 2013. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTR1.html)
- P. M. Anderson and R. G. Farmer, Series compensation of power systems. Encinitas, CA, USA: PBLSH, 1996.
- F. Milano, F. Dörfler, G. Hug, D. J. Hill, and G. Verbic, "Foundations and challenges of low-inertia systems," in 20th Power Systems Computation Conference (PSCC), Dublin, Ireland, 2018.
- Stability definitions and characterization of dynamic behavior in systems with high penetration of power electronic interfaced technologies, IEEE Power and Energy Society, Tech. Rep. PES- TR77, May 2020. (available on-line: https://resourcecenter.ieee- pes.org/technical-publications/technical- reports/PES_TP_TR77_PSDP_stability_051320.html)
- Contribution to Bulk System Control and Stability by Distributed Energy Resources Connected at Distribution Network, IEEE Power and Energy Society, Tech. Rep. PES-TR22, Jan. 2017. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTRPDFMRH0022.html)
- Microgrid Stability, Definitions, Analysis, and Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR66, Jun. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PES_TR0066_062018.html)
- North American Electric Reliability Corporation (NERC), "Integrating inverter -based resources into low short circuit strength systems: reliability guideline," Reliability Guideline, Dec. 2017.
- T. Souxes and C. Vournas, "System Stability Issues Involving Distributed Sources under Adverse Network Conditions," Bulk Power Systems Dynamics and Control -X (IREP), Porto, Portugal, Sept. 2017.
- P. Pourbeik, S. Soni, A. Gaikwad, and V. Chadliev, "Providing primary frequency response from photovoltaic power Plants," in CIGRE Symposium 2017, Dublin, Ireland, 2017.
- Impact of Inverter Based Generation on Bulk Power System Dynamics and Short-Circuit Performance, IEEE Power and Energy Society, Tech. Rep. PES -TR68, Jul. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical-publications/technical- reports/PES_TR_7-18_0068.html)
Cited by
Items 901–1,000 of 1,000
Krahmer, S., Ecklebe, S., Schegner, P., & Röbenack, K. (2023) · at - Automatisierungstechnik · doi:10.1515/auto-2023-0142 · Cited by 1
Sun, R., & Yuan, X. (2023) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre59655.2023.10353800 · Cited by 1
“In addition, the AC voltage waveform generated by the fast variations of the A/F is visually distinct from the standard sine signal and exhibits non-periodic behavior [14], [15].”
BackgroundZhang, S., Zhang, X., & Lü, C. (2023) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre59655.2023.10353747 · Cited by 1
Mao, J., Gu, T., He, Y., Xu, Y., Gao, J., & Lin, C. (2023) · International Conference on Smart Grids and Energy Systems (SGES) · doi:10.1109/sges59720.2023.10366893 · Cited by 1
“Transient stability is related to power system’s capacity to remain in synchronization to large disturbance [1] .”
BackgroundA Simplified Online Stability Monitoring Method for Grid-Connected Systems
Zhou, Y., Liu, J., Liu, Z., & Wu, T. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362306 · Cited by 1
“The power electronics equipment provides excellent performance while also bringing more critical stability problems, affecting the stable operation of the power system [2].”
BackgroundWürfel, H., Lorenz‐Meyer, N., & Schiffer, J. (2023) · IEEE Workshop on the Electronic Grid (eGRID) · doi:10.1109/egrid58358.2023.10380931 · Cited by 1
“Consequently, analysis and high-accuracy simulations of diverse stability phenomena, such as resonance and inverter-driven stability, are increasingly important for a reliable and secure system operation [3].”
BackgroundGoeritno, A., Hendrawan, T., & Azama, I. M. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1002769 · Cited by 1
Zhou, W., & Beerten, J. (2024) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2024.3360091 · Cited by 1
“wide-band low stability margin, resonance, or even instability under weak grid conditions [3].”
BackgroundTerms, Classifications, and Mechanisms of Wideband Oscillations
Xie, X., & Shair, J. (2024) · Power systems · doi:10.1007/978-3-031-53357-0_2 · Cited by 1
Limitations in Impedance Reshaping of Grid Forming Converters for Instability Prevention
Shah, C. R., Molinas, M., Nilsen, R., & Amin, M. (2023) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec58486.2023.10458509 · Cited by 1
“Inclusion of power converters in the power grid has introduced two new stability challenges: Resonance stability and Converter-driven stability [2].”
Modelling of a Nonlinear Swing Equation for a Non-salient Pole Rotor Synchronous Generator
Murad, N. S. F. M., Kamarudin, M. N., Ismail, M. F., & Rozali, S. M. (2024) · IEEE International Conference in Power Engineering Applications (ICPEA) · doi:10.1109/icpea60617.2024.10498450 · Cited by 1
Zhang, X., Li, Z., Wang, Z., Chen, D., & Zhang, W. (2023) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei259745.2023.10512422 · Cited by 1
“The ever-increasing integration of voltage source converter (VSC) interfaced renewable resources has a significant impact on the stability of modern power systems [1].”
BackgroundNovel Frequency Regulation Scheme of Grid-Forming MMC-HVDC with DC-ESS for Wind Farm Integration
Yuan, X., Yu, D., Zong, Y., Zheng, K., Chen, S., Liang, L., Wei, C., & Peng, H. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532701 · Cited by 3
“Due to the volatility of the wind turbine (WT) output power, large-scale wind farm integration will significantly affect the normal operation [2] of power grids.”
BackgroundOscillation Source Identification Using Dissipating Energy Flow in Northeastern Thailand Power Grid
Jongjarussang, T., Chirapongsananurak, P., & Wangdee, W. (2024) · International Electrical Engineering Congress (iEECON) · doi:10.1109/ieecon60677.2024.10537976 · Cited by 1
“Furthermore, resonance and converter-driven stability have been newly categorized, besides the rotor angle, voltage, and frequency stability, in the revised power system stability definition [3].”
BackgroundComparison of Different Tuning Approaches for Multi-band Power System Stabilizers
Kalke, D., Gurrala, G., & Sahu, V. (2023) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec57400.2023.10561926 · Cited by 1
A generalized time-domain framework for modeling and analysis of the unbalanced three-phase systems
Tayyebi, A., Zhang, W., Huang, X., Jiang, W., Bormann, D., & Larsson, M. R. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110809 · Cited by 1
A comparative Analysis of Machine Learning Methods for Power System Transient Stability
Justin, G. (2024) · Global Power, Energy and Communication Conference · doi:10.1109/gpecom61896.2024.10582711 · Cited by 1
“Power system stability is the ability of an electric power system to regain a state of equilibrium following a physical disturbance [1].”
BackgroundInfluentialAnti-Interference System for Power Sensor Signals under Artificial Intelligence
Hu, H., Ma, C., Wang, X., Zhang, Z., & AiZeZi, A. (2024) · International Conference on Data Science and Information System (ICDSIS) · doi:10.1109/icdsis61070.2024.10594691 · Cited by 1
“…resistance, any type of noise can be absorbed by the short circuit of the power supply and can not form interference voltage on the line; In addition, servo power systems themselves are also a strong source of interference, which can interfere with other devices through power supply methods [6-7].”
BackgroundChanging Power Systems and Impact on Power System Dynamic Phenomena and Analysis Methods
Badrzadeh, B., Emin, Z., & Gu, Y. (2024) · CIGRE green books · doi:10.1007/978-3-031-47821-5_1 · Cited by 1
A Recap of Modern Power Grid Control Systems
Nomandela, S., Mnguni, M. E. S., & Raji, A. K. (2024) · Asia Conference on Energy and Electrical Engineering (ACEEE) · doi:10.1109/aceee62329.2024.10651690 · Cited by 1
“However, some large disturbances can also be long-term [4].”
BackgroundA Quantitative Assessment of the Impact of Renewable Energy on Power System Frequency Stability
Lu, Y., Chen, X., Li, S., Wu, L., & Su, Q. (2024) · International Conference on Energy Systems and Electrical Power (ICESEP) · doi:10.1109/icesep62218.2024.10651677 · Cited by 1
“Renewable energy goes through the power electronic converter and into the power grid, resulting in the unit output power and frequency decoupling, which does not respond to system frequency changes [1] .”
BackgroundArtificial Intelligence Techniques in Distribution Systems
Ranjbar, S., & Abedi, M. (2024) · Power systems · doi:10.1007/978-3-031-69358-8_11 · Cited by 2
Performance of IBR Power Oscillations Damper according to power system operating conditions
Gomis-Domènech, M., Do, T. P., & Caire, R. (2024) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope62998.2024.10863279 · Cited by 1
A Comprehensive Synthesis of Frequency Stability in Isolated AC Microgrids
Abedini, F., & Teuscher, J. (2024) · International Conference on Smart Systems and Power Management (IC2SPM) · doi:10.1109/ic2spm62723.2024.10841338 · Cited by 1
“1, frequency stability could be further divided into two categories, namely long-term and short-term [6].”
Power Equipment Fault Image Recognition and Diagnosis Based on Convolutional Neural Network
Li, X. (2025) · International Conference on Sentiment Analysis and Deep Learning (ICSADL) · doi:10.1109/icsadl65848.2025.10933017 · Cited by 2
“The modern power system is the backbone and core sector of the national economy, and its safe and reliable operation is of vital importance [1] – [3].”
Taghilou, M., & Mirsalim, M. (2024) · doi:10.1109/icemd64575.2024.10963426 · Cited by 1
“Tap changers, integral components of transformers, play a pivotal role in maintaining voltage stability across varying load conditions [1][2].”
Evaluating network reliability under loss rates for stochastic flow power networks
Huang, C. (2025) · Annals of Operations Research · doi:10.1007/s10479-025-06692-8 · Cited by 1
Yoon, Y., Jang, J., Zhang, X., Cho, J., & Choi, S. (2025) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias62731.2025.11061527 · Cited by 1
“I N high penetration of IBR, the new classification of power system stability has been noticed in [1].”
Improving the Dynamic Response of PI Voltage Modulated-Direct Power Controlled Grid-tied VSIs
Papageorgiou, P. C., Alexandridis, A. T., & Konstantopoulos, G. C. (2025) · European Control Conference (ECC) · doi:10.23919/ecc65951.2025.11187005 · Cited by 1
“In addition, the fast action of these synchronization loops can interact with other dynamic phenomena taking place on a wider system area, in the same time scale, i.e. electromagnetic transients or electromechanical dynamics [9].”
Liu, W., Liu, D., Jiang, Y., Zhu, S., Wu, X., & Lü, C. (2025) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52009.2025.11225706 · Cited by 1
When do we need electromagnetic transient (EMT) simulations? [In my View]
Panciatici, P. (2025) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2025.3552012 · Cited by 1
Machado, S. D. J. M., da Silva, S. A. O., & Monteiro, J. R. B. D. A. (2021) · Brazilian Power Electronics Conference (COBEP) · doi:10.1109/cobep53665.2021.9684120 · Cited by 1
Editorial Best Papers, Outstanding Associate Editors, and Outstanding Reviewers
Milanović, J. V., & Hatziargyriou, N. D. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3150670 · Cited by 1
Self-citationStability and Reliability Validation of Microgrid Systems
Song, Y. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561825401 · Cited by 1
Concurrent Reliability and Stability Analysis for Risk Assessment of MicroGrids and Power Systems
Azizi, A. (2024) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau756453622 · Cited by 1
Recommended Practices for Wind/PV Integration Studies, 3rd Edition
Holttinen, H., & Helistö, N. (2025) · doi:10.69766/luhx8335 · Cited by 1
Peng, X., Fu, C., Yang, P., Ru, X., & Liu, F. (2025) · doi:10.36227/techrxiv.173091861.14722345/v3 · Cited by 1
Identification of Sub/Super-Synchronous Control Interaction Paths Using Dissipative Energy FlowPreprint
Chatterjee, K., Nekkalapu, S., Mukherjee, S., Hossain, R. R., & Elizondo, M. (2025) · arXiv (Cornell University) · Cited by 1
Munazza, M. (2025) · Aaltodoc (Aalto University) · Cited by 1
Rossi, F., Lorenzo, M. G., de Acevedo, E. I., Barriendos, E. M., Lacerda, V. A., Lordan-Gomis, F., Badia, R., & Prieto‐Araujo, E. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2512.06369 · Cited by 1
“These phenomena appear on distinct time scales: electromechanical dynamics evolve relatively slowly, typically over seconds, whereas electromagnetic dynamics occur on the order of microseconds due to the high switching frequencies and fast control loops of power electronic converters [1].”
Technical and Commercial Comparison of AC- and DC-Coupled Battery Energy Storage Systems
Matikainen, K. (2024) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Garcia-Reyes, L. A., Arévalo-Soler, J., Gomis‐Bellmunt, O., Prieto‐Araujo, E., Lacerda, V. A., Almenta, M. M., Nuño, E., & Renedo, J. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2605.11140 · Cited by 1
Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator ResponsePreprint
Shan, L. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2608.15122 · Cited by 1
“P OWER systems with high renewable and inverter-based generation are increasingly exposed to voltage stability risks [1].”
Impacts of Heterogeneous Grid-Forming Devices on Power System Dynamics Quantified by DW ShellsPreprint
Luo, L., Huang, L., Chen, H., Leng, R., Hou, Z., Zhuang, K., & Xin, H. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2608.21984 · Cited by 1
Control del ángulo del fasor de voltaje en sistemas de potencia
Sierra, V., & Federico, J. (2021)
Morais, M. A. C., da Cunha, G. L., Geraldi, E. L., & Fernandes, T. C. D. C. (2021) · IEEE International Conference on Industry Applications · doi:10.1109/induscon51756.2021.9529512
“Neste método, técnicas de processamento de sinal são aplicados aos sinais amostrados de um SEP pelas unidades de medição fasorial (do inglês, Phasor Measurement Units - PMUs) [9], [10].”
BackgroundInfluentialNeural ODE and DAE Modules for Power System Dynamic Modeling.Preprint
Xiao, T., Chen, Y., He, T., & Guan, H. (2021) · arXiv (Cornell University)
Yuan, X., Li, Y., Jiang, H., Qu, T., Xu, Y. H., & Du, Z. (2022) · International Conference on Power Energy Systems and Applications (ICoPESA) · doi:10.1109/icopesa54515.2022.9754463
“With large-scale integration of converter-interfaced WT, the dynamic behaviors of the modern power systems are undergoing profound revolutions [1] in which the low level of inertia and low level of short circuit ratio (SCR) will become the common operating conditions, largely endangering the power system stability.”
BackgroundZhou, W., Mohammed, N., & Bahrani, B. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9806832
“INTRODUCTION The utilization of power electronic converters leads to the inertia reduction and potential adverse control interactions, which may threaten the system reliable and safe operations [1].”
BackgroundSuvorov, A. A., Аскаров, А. Б., Рудник, В. Е., Разживин, И. А., Андреев, М. В., & Bhalja, B. R. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4108853
Mbaimbai, N. (2021) · DUT Open Scholar (Durban University of Technology) · doi:10.51415/10321/4265
del Giudice, D., Bizzarri, F., Linaro, D., & Brambilla, A. (2022) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-12818-9_1
Rotor angle stability-constrained dispatch and control of large-scale wind penetrated power system
Yuan, H. (2022) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/162119
Hou, Q., Jia, H., Xia, T., Zhang, Z., Cai, X. H., Wang, J., & Zhang, N. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821204-2.00143-4
Effect of Active Power Injection on the Voltage Stability Margin of a Power System
Cherif, K. Y., Latiki, L., Medjdoub, A., & Taib, N. (2022) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem55808.2022.10043916
Power Electronics in Modern Power Systems
Chen, Z. (2022) · International Conference on Power Electronics Systems and Applications · doi:10.1109/pesa55501.2022.10038350
“Reference [5] further explained the new classification of power system stability.”
BackgroundRahmansyah, A. R., Krismanto, A. U., & Sulistiawati, I. B. (2022) · Journal of Applied Smart Electrical Network and Systems · doi:10.52158/jasens.v3i01.333
Giannakopoulos, G., Perilla, A., Rueda, J. L., Pálenský, P., & Gonzalez-longatt, F. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18426-0.00008-x
Suvorov, A. A., Аскаров, А. Б., Рудник, В. Е., Разживин, И. А., Андреев, М. В., & Bai, Y. D. (2022) · Power Technology and Engineering · doi:10.1007/s10749-023-01506-y
Tang, W., Zhang, R., Li, W., Liu, Y., & Zhai, S. (2022) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec55080.2022.10058388
“The transient stability problems have been occurs in such DFIG-WT dominated system, which also draws researchers’ attentions [1]-[3].”
BackgroundAnalytical Reliability-Based Investment and Operation Model for Post-Failure Network Reconfiguration
Marquez, J. L. A., Al-Ja’Afreh, M. A. A., Mokryani, G., Kabir, S., Campean, F., Dao, C. D., & Riaz, S. (2022) · International Conference on System Reliability and Safety (ICSRS) · doi:10.1109/icsrs56243.2022.10067558
“Thus system adequacy focuses on the system's design, structure, and installed component capacity [8].”
BackgroundEffect of GFM Inverters on Power System Stability-I
Zoka, Y., & Yorino, N. (2023) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.143.204
Transition Stability Phase Portrait Analysis and Pi-Based Improved Control of Grid-Forming ConverterPreprint
Xing, Y., Zhang, G., Yang, K., Li, J., Cai, D., Bamisile, O., & Huang, Q. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4462843
Liu, Z., Xu, X., Shen, Y. Q., Wang, K., Su, Y., & Li, W. (2023) · International Conference on Power Energy Systems and Applications (ICoPESA) · doi:10.1109/icopesa56898.2023.10141489
Song, S., Yang, J. B., Rashed, G. I., Shen, J., Peng, X., Haider, H., Jiang, K., Liu, D., & Cao, K. (2023) · doi:10.22541/au.168786964.42293829/v1
Xu, Y., Hu, Z., Wu, Y., Tian, A., Wang, Z., & Wu, T. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4509546
Dan, Y., He, Y., Zhou, H., Zhu, Y., & Zhou, Y. (2023) · International Conference on Mechanical, Electronics and Electrical and Automation Control (METMS) · doi:10.1117/12.2680401
“If the post-disturbance transient stability is not evaluated in time, the transient instability may induce serious cascading failures and even large-scale outages [2].”
BackgroundZhang, X., Hou, K., Yang, J., Hu, J., Yao, G., & Zhang, J. (2023) · Energies · doi:10.3390/en16155762
Estimating Unobservable Machines in Multi-Area Power Systems Considering Model Imperfections
Vehn, A. T., & Nordström, L. (2023) · IEEE PowerTech Conference · doi:10.1109/powertech55446.2023.10202749
“INTRODUCTION With increasing degrees of converter interfaced generation and loads, power systems will experience a decrease in short circuit ratios and inertia [1], creating a more dynamic system.”
BackgroundMultimode Power Oscillation Damping Controller Synthesis using Vector Fitting
Jankovic, N., Roldán‐Pérez, J., Prodanović, M., D’Arco, S., Suul, J. A., & Rouco, L. (2023) · IEEE PowerTech Conference · doi:10.1109/powertech55446.2023.10202695
Александрович, А. А., ILYUSHIN, P. V., Suslov, K., & Domyshev, A. (2023) · IEEE PowerTech Conference · doi:10.1109/powertech55446.2023.10202878
On-line System Identification of Power System Linear Models
Moreno-Corbea, J. A., Paternina, M. R. A., Rodales, D., Reyes, R., Zelaya, F., Zamora, A., Toledo, C., Castrillón-Franco, C., & Sánchez, A. (2023) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52003.2023.10252494
Research Trends on Power System Stabilization for Integration of Renewable Energy Sources
Kawabe, K. (2023) · IEEJ Transactions on Power and Energy · doi:10.1541/ieejpes.143.574
Oyando, H. C., Wachira, K., & Likare, H. P. (2023) · IEEE AFRICON · doi:10.1109/africon55910.2023.10293483
“Power system stability is defined by its voltage and frequency stability [1].”
BackgroundKernbichler, A. M., & Fernandes, T. C. D. C. (2022) · Congresso Brasileiro de Automática · doi:10.20906/cba2022/3557
Data-driven secondary voltage control design using PMU measurements
do Nascimento, M. M. (2021) · doi:10.47749/t/unicamp.2021.1166514
Eigenvalue-curve approach for fast assessment of rotor angle transient stability
Wolter, M., & Glende, E. (2023) · at - Automatisierungstechnik · doi:10.1515/auto-2023-0164
Schöll, C., & Lens, H. (2023) · at - Automatisierungstechnik · doi:10.1515/auto-2023-0143
PHIL-based Impedance Measurement for Electromagnetic Stability Analysis of Grid-following Converters
Purgat, P., Wurz, J., & Srdic, S. (2023) · AEIT International Annual Conference · doi:10.23919/aeit60520.2023.10330370 · Cited by 1
“In order to include the effects of the IBRs to the power system stability, the traditional approach was extended to include two new stability categories: Converter-driven stability and Resonance stability [4].”
MethodPrediction and Mitigation of Power System Inter-Area Oscillation Mode Based on Single Index ModelPreprint
Mo, W., Lv, J., Pawlak, M., & Chen, H. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4672038
Small Signal Stability Analysis of DFIG IEC IIIB Integrated into Small Interconnection Power System
Nababan, B. P., Simanullang, F. N. T. P., Marbun, M. P., & Rahman, F. S. (2023) · International Conference on Technology and Policy in Energy and Electric Power (ICT-PEP) · doi:10.1109/ict-pep60152.2023.10351172
“The integration of converter-based generators, such as DFIG, into the system, can yield either adverse or advantageous consequences, contingent upon the system's conditions, characteristics, and strength, the employed control method, the level of system loading, and other contributing factors [13].”
BackgroundPrediction of Frequency Response of Power Grid: An Ensemble Learning Based Approach
Jawad, A., Arnab, S. M. R., Uddin, M. R., & Al-Masood, N. (2023) · International Conference on Technology and Policy in Energy and Electric Power (ICT-PEP) · doi:10.1109/ict-pep60152.2023.10351151
“It refers to the system's capability to return to a state of equilibrium following a physical disturbance, given its initial operating condition [1].”
BackgroundInstability Detection for Operation State Monitoring of the Grid-Tied Inverter
Fang, J., & Yang, S. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362807
“The characteristic frequency of the unstable behaviors covers a wide range [18-19].”
BackgroundModified Steady-State Power Flow for Grid with High Penetration of Inverter-Based Resource
Seo, S., Muljadi, E., Nguyen, Q., Datta, S., Samaan, N., Vyakaranam, B. G., Du, W., Liu, Y., Chen, Y., Kim, J., et al. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362225
“…dominated by synchronous generators (SGs) with predictable dynamic responses from rotating masses, the modern power system, which includes IBRs and many other distributed generators, needs new analytic approaches because the fast response of the IBRs produces changes in dynamic behaviors [1].”
BackgroundWan, K., Mu, S., Ding, P., Cai, J., Xu, X., & Zhao, M. (2023) · International Conference on Power and Energy Technology (ICPET) · doi:10.1109/icpet59380.2023.10367439
“With the rapid increase in the scale of interconnected power grids and electricity demand, analyzing the potential voltage stability risks in the system has become an essential task [1-5].”
BackgroundFilho, D. P. C., Medrado, R. C., Miranda, R. L., Filho, D. F. G., Filho, M. D. C., & Filho, J. B. D. M. (2023) · IEEE International Conference on Industry Applications · doi:10.1109/induscon58041.2023.10375029
“The operational impacts of large-scale converter-interfaced generation (CIG) penetration in power systems became a pressing issue [1], as assimilation of alternative energy resources increases.”
BackgroundState of Energy Based Secondary Control Scheme of Virtual Power Plant
Kim, G.-H., Kang, K.-S., Jeung, Y.-C., Choi, Y.-J., Kang, G.-H., & Ko, H.-S. (2023) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific59272.2023.10372345
Power System Stability Assessment System Based on Big Data Analysis
Hou, Z., Rong, T., & Gu, J. (2023) · IEEE International Conference on Data Science and Computer Application (ICDSCA) · doi:10.1109/icdsca59871.2023.10392585
“[8] The sample data processing module includes a data filtering unit, a data classification unit, and a storage unit.”
MethodViglov, K. (2023) · Electrical Engineering Faculty Conference (BulEF) · doi:10.1109/bulef59783.2023.10406291
Reis, L., Smith, A. M., D’Arco, S., & Suul, J. A. (2023) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope56780.2023.10407790
You, C., Xiao, X., Shen, C., Choudhury, S., & Hanson, J. (2023) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope56780.2023.10408658
“As is figured out in [4–6], among the various kinds of power system stability classified in [7], small-disturbance oscillatory stability deserves to be paid attention to in large-scaled transmission grids, because the large amount of generators bring out usually lots of rotor oscillation modes, and…”
BackgroundExperimentally validated resonance instabilities in distribution grids with high inverter shares
Simon, S., Stroot, M., & Ulbig, A. (2023) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope56780.2023.10407354
PLL-Based Resonance of a Type-4 Wind Generator in a Series-Compensated Transmission Line
Hernández-Ramírez, J., & Segundo‐Ramírez, J. (2023) · IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC) · doi:10.1109/ropec58757.2023.10409372
“Such has been the relevance of these new issues that the traditional stability definitions used to study electric networks have added new categories that are related to oscillations caused by the interactions of the power electronics in the networks [6].”
BackgroundVoltage Stability Analysis of Multi-microgrid Clusters
Wang, L., Chen, L.-W., & Liu, Y. (2023) · IEEE International Conference on Energy Technologies for Future Grids (ETFG) · doi:10.1109/etfg55873.2023.10407384
“The paper [2] reviewed and expanded the definition of basic stability and introduced new classifications, incorporating fast-responding power electronic devices.”
BackgroundMethodLiu, Y., Zhang, H., Qiu, Y., Gao, J., & Zhang, S. (2023) · International Conference on Mobile Networks and Wireless Communications (ICMNWC) · doi:10.1109/icmnwc60182.2023.10435982
“…is to achieve the optimal energy efficiency of the power energy system, and to construct corresponding objective functions from the perspectives of reducing capital investment, energy investment, manual investment, carbon dioxide emissions, and comprehensive consideration of social effects [9-10].”
BackgroundModal Analysis of Strong Resonance in Multi-Machine System with Power System Stabilizer
Naik, J. S., & Thirumalaivasan, R. (2024) · International Journal of Electrical and Electronics Engineering · doi:10.14445/23488379/ijeee-v11i2p105
Metadata
- Authors
- Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., Pourbeik, P., Sanchez-Gasca, J., Stankovic, A., Van Cutsem, T., Vittal, V., & Vournas, C.
- Affiliations
- National Technical University of Athens (GR)
- University of Chile (CL)
- Iowa State University (US)
- University of Duisburg-Essen (DE)
- University of Hong Kong (HK)
- University of Michigan (US)
- Hydro-Québec (CA)
- Imperial College London (GB)
- General Electric (United States) (US)
- Arizona State University (US)
- ORCID
- Venue
- IEEE Transactions on Power Systems
- Published
- 2021-07
- Volume
- 36
- Issue
- 4
- Pages
- 3271-3281
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3110874572
- Cited by
- 1,244
- References
- 89
- Citations by year
- 2026: 242 · 2025: 286 · 2024: 274 · 2023: 237 · 2022: 152 · 2021: 52
- FWCI
- 37.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Power Systems (publishedVersion, cc-by)
- Open Repository and Bibliography (University of Liège) (submittedVersion, cc-by)
- Research Explorer (The University of Manchester) (submittedVersion, cc-by)
- Universidad de Chile (submittedVersion, cc-by-nc-nd)
- Funders
- Engineering and Physical Sciences Research Council (EP/T021713/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- power system stability, stability definitions, stability classification, converter-interfaced generation, power devices, transmission device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
![Fig. 1 Power system times scales [3].](https://figures.cochat.ai/paper-figures/164b0e6732b447d6b5ecb5927b7f989c/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-1.png)
![Fig. 2 Classification of power system stability [3].](https://figures.cochat.ai/paper-figures/a79bfd894fd8407790c6b5a89935f15e/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-2.png)
![Fig. 3 An illustration of power system frequency response to a major loss of generation. (IEEE © 2013, reproduced from [32])](https://figures.cochat.ai/paper-figures/d327b48f98464ab6ba883eb6f355f691/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-3.png)