Definition and Classification of Power System Stability – Revisited & Extended
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Since the publication of the original paper on power system stability definitions in 2004, the dynamic behavior of power systems has gradually changed due to the increasing penetration of converter interfaced generation technologies, loads, and transmission devices. In recognition of this change, a Task Force was established in 2016 to re-examine and extend, where appropriate, the classic definitions and classifications of the basic stability terms to incorporate the effects of fast-response power electronic devices. This paper based on an IEEE PES report summarizes the major results of the work of the Task Force and presents extended definitions and classification of power system stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“AI approaches, which mimic human thought, may be helpful [87]: they mentioned in their study that recent developments include using ANN to maintain steady-state security and FL applications for determining the reliability of power systems using the interrupted energy assessment rate given in [88].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [87]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Self-citationGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 1×
“The vast majority of large-scale CIGs use voltage-source converters [11], [12], or some derivative thereof, allowing designs that offer full four-quadrant control.”
BackgroundDesign and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402 · cited 1×
“The resonance of an inverter filter can also be triggered by the control of the inverter itself or by interactions with nearby controllers [76].”
BackgroundVoltage‐Sourced Converters in Power Systems: Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Wiley eBooks · doi:10.1002/9780470551578 · Cited by 2,264
Voltage Stability of Electric Power Systems
Cutsem, T., & Vournas, C. (1998) · Springer eBooks · doi:10.1007/978-0-387-75536-6 · Cited by 2,036
Self-citationKroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367 · cited 1×
“5) Converter-driven Stability: The dynamic behavior of CIG is clearly different from conventional synchronous generators, due to the predominant VSC interface with the grid [70].”
BackgroundHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 1×
“the electromagnetic transients of the network, which may lead to unstable power system oscillations over a wide frequency range [71].”
BackgroundWind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Research works printed but not linked: 11
- P. Pourbeik and J. K. Petter, "Modeling and validation of battery energy storage systems using simple generic models for power system stability studies," Cigre Sci. Eng., no. 9, pp. 63-72, Oct. 2017.
- Dynamic Models for Turbine-Governors in Power System Studies, IEEE Power and Energy Society, Tech. Rep. PES -TR1, Jan. 2013. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTR1.html)
- P. M. Anderson and R. G. Farmer, Series compensation of power systems. Encinitas, CA, USA: PBLSH, 1996.
- F. Milano, F. Dörfler, G. Hug, D. J. Hill, and G. Verbic, "Foundations and challenges of low-inertia systems," in 20th Power Systems Computation Conference (PSCC), Dublin, Ireland, 2018.
- Stability definitions and characterization of dynamic behavior in systems with high penetration of power electronic interfaced technologies, IEEE Power and Energy Society, Tech. Rep. PES- TR77, May 2020. (available on-line: https://resourcecenter.ieee- pes.org/technical-publications/technical- reports/PES_TP_TR77_PSDP_stability_051320.html)
- Contribution to Bulk System Control and Stability by Distributed Energy Resources Connected at Distribution Network, IEEE Power and Energy Society, Tech. Rep. PES-TR22, Jan. 2017. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTRPDFMRH0022.html)
- Microgrid Stability, Definitions, Analysis, and Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR66, Jun. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PES_TR0066_062018.html)
- North American Electric Reliability Corporation (NERC), "Integrating inverter -based resources into low short circuit strength systems: reliability guideline," Reliability Guideline, Dec. 2017.
- T. Souxes and C. Vournas, "System Stability Issues Involving Distributed Sources under Adverse Network Conditions," Bulk Power Systems Dynamics and Control -X (IREP), Porto, Portugal, Sept. 2017.
- P. Pourbeik, S. Soni, A. Gaikwad, and V. Chadliev, "Providing primary frequency response from photovoltaic power Plants," in CIGRE Symposium 2017, Dublin, Ireland, 2017.
- Impact of Inverter Based Generation on Bulk Power System Dynamics and Short-Circuit Performance, IEEE Power and Energy Society, Tech. Rep. PES -TR68, Jul. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical-publications/technical- reports/PES_TR_7-18_0068.html)
Cited by
Items 401–500 of 1,000
Rueda, J. L., Veerakumar, N., Rakhshani, E., Ahmad, Z., Adabi, M. E., Pálenský, P., & van der Meijden, M. A. M. M. (2021) · Electronics · doi:10.3390/electronics10141651 · Cited by 7
“, high inertia within a time frame of several milliseconds) against steep RoCoF, whenever a sudden perturbation of the active power balance occurs [3].”
BackgroundYuan, X., Du, Z., Li, Y., & Xu, Z. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.13117 · Cited by 7
Islam, S. U., & Kim, S. (2023) · Sustainability · doi:10.3390/su15086705 · Cited by 7
Oscillatory frequency characterization based on impedance analysis
Mateu-Barriendos, E., Cheah-Mañé, M., Prieto‐Araujo, E., Mehrjerdi, H., & Gomis‐Bellmunt, O. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109208 · Cited by 7
An Algorithm for DC Segmentation of AC Power Systems to Mitigate Electromechanical Oscillations
Robin, M., Renedo, J., Gonzalez‐Torres, J. C., García‐Cerrada, A., Benchaib, A., & García-González, P. (2023) · IEEE Access · doi:10.1109/access.2023.3287782 · Cited by 7
Chiorean, D.-L., Bică, D., Gorea, C., Vlasa, I., Hurducaci, C.-C., & Mandiş, A. (2023) · International Conference on Modern Power Systems (MPS) · doi:10.1109/mps58874.2023.10187594 · Cited by 7
“The structure of the paper ”Optimizing the Operation of Electrical Energy Storage Systems Obtained from Renewable Sources Using Artificial Intelligence” is designed to explore the importance of using artificial intelligence to improve the performance of electrical energy storage systems [4].”
BackgroundHafidz, I., Mahendra, R. A. I., Pujiantara, M., Priyadi, A., & Purnomo, M. H. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12956 · Cited by 7
Zhuang, K., Wang, Z., Sun, D., Wu, L., Wang, X., & Xin, H. (2023) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52003.2023.10253110 · Cited by 7
“In recent years, the instability caused by wind turbines has been reported more and more, and the safe and stable operation of the grid with high proportion of wind power generation is facing severe challenges [1].”
Nascimento, M. R. B. D. M., Ramos, F. A., ALMEIDA, L. C. B. D., Gonçalves, N. V. C., Grilo, A. P., & Ramos, R. A. (2023) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52003.2023.10252463 · Cited by 7
Universal SSO Stabilization of Renewable Energy Power Systems
Wang, L., & Liu, P. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3346497 · Cited by 7
“Moreover, limited by Nyquist or eigenvalue criterion, the modal-based or impedance-based stability analysis results are not easy to be analytically resolved in large-scaled REPS [9].”
BackgroundNavigating the Smart Grid Landscape: A Comprehensive Review of Recent Advances
Sai, V. G. S., Divya, R., & Nair, M. G. (2025) · International Conference on Power, Control and Computing Technologies (ICPC2T) · doi:10.1109/icpc2t63847.2025.10958759 · Cited by 8
Ambient forcing: sampling local perturbations in constrained phase spaces
Büttner, A., Kurths, J., & Hellmann, F. (2022) · New Journal of Physics · doi:10.1088/1367-2630/ac6822 · Cited by 7
Shirasaki, K., & Amano, H. (2022) · IEEJ Transactions on Power and Energy · doi:10.1541/ieejpes.142.243 · Cited by 7
Mandoulidis, P., Chaspierre, G., Vournas, C. D., & Cutsem, T. V. (2022) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2022.100710 · Cited by 7
“The proliferation of Inverter Based Generators (IBG) in the distribution grids has caused concerns over recent years about their effect on system dynamics and stability [1].”
BackgroundSelf-citationSimultaneous prediction of voltage and frequency stability based on game theory
Mohammadniaei, M., Namdari, F., & Shakarami, M. R. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108245 · Cited by 7
An Analytical Formula for Small Signal Stability Sensitivity Using SDP Dual
Wang, J., Song, Y., Hill, D. J., & Hou, Y. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3328163 · Cited by 7
Self-citationTamang, B., Gurung, S., & Chapagain, K. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.13044 · Cited by 7
Optimal power flow schedules with reduced low-frequency oscillations
Singh, M. K., & Kekatos, V. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108301 · Cited by 7
Index System for Evaluating the Supporting Capability of the Inverter-based Resource
Liu, Y., Chen, J., Ge, C., Wang, K., Chang, X., & Zhao, Q. (2023) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52003.2023.10252238 · Cited by 7
Transient Voltage Stability: A Review of Practical Criteria and Assessment Indices
Dong, Z., Wu, H., Liu, Y., Jiang, C., Ma, S., Zhang, L., & Gong, H. (2025) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.70166 · Cited by 7
Taher, A. M., Hasanien, H. M., Al‐Gahtani, S. F., Ali, Z. M., Zobaa, A. F., & Aleem, S. H. E. A. (2025) · Scientific Reports · doi:10.1038/s41598-025-23150-4 · Cited by 6
A Comprehensive Approach to Evaluate Frequency Control Strength of Power Systems
Kërçi, T., & Milano, F. (2025) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2025.3643748 · Cited by 6
“For example, as the inertia decreases with the displacement of conventional synchronous generators there is a concern that frequency excursions become faster, and therefore the likelihood of instability occurring earlier increases [3].”
Ncwane, S., & Bansal, R. C. (2026) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2026.116833 · Cited by 6
Aghahassani, M., Ledesma, P., Castronuovo, E. D., & Arredondo, F. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2023.110089 · Cited by 6
Ponce, I., & Milano, F. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110662 · Cited by 6
Alhelou, H. H., Bahrani, B., & Ma, J. (2024) · IEEE Transactions on Energy Markets Policy and Regulation · doi:10.1109/tempr.2024.3421888 · Cited by 6
“According to IEEE/CIGRE joint task-force (TF) on stability terms and definitions, power system stability can be divided into three categories, i.e. Frequency, rotor angle, and voltage stabilities [2].”
Reserve Technique in Integrating Large Sustainable Energy Sources: A Case Study of the Tunisian Grid
Mansouri, N., Lashab, A., Ali, M., Bouchoucha, C., Guerrero, J. M., & Vásquez, J. C. (2024) · Sustainability · doi:10.3390/su162310791 · Cited by 6
“The quality of electrical production is characterized by the waveform, amplitude, and frequency of the voltage generated by the production system [9,10].”
Relić, F., Glavaš, H., Petrović, I., & Stojkov, M. (2024) · Tehnicki vjesnik - Technical Gazette · doi:10.17559/tv-20240502001515 · Cited by 6
“Due to their increased use, two new stability categories were introduced in [15].”
Wang, W., Dong, S., Liu, W., Motakatla, V. R., Basnet, P., & Fang, X. (2025) · North American Power Symposium (NAPS) · doi:10.1109/naps66256.2025.11272399 · Cited by 6
Ávila-Martínez, R. E., Guillaud, X., Renedo, J., Rouco, L., García‐Cerrada, A., & Sigrist, L. (2026) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.111540 · Cited by 6
Li, D., Sun, Q., Wang, R., Wang, P., Sui, Z., & Wang, P. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3659929 · Cited by 6
“However, semiconductor-based inverters exhibit limited overcurrent tolerance,sustainingmerely20%–40%beyondratedcurrentcapacity [4].”
Albustami, A. A., & Taha, A. (2026) · Applied Energy · doi:10.1016/j.apenergy.2026.129216 · Cited by 7
Tavela, F. M., Filho, J. A. P., & Avila, O. F. (2022) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-021-00870-2 · Cited by 6
Arzani, A., Ramasubramanian, D., & Mitra, P. (2024) · IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt59692.2024.10454221 · Cited by 6
“In fact, a recently published report by the joint IEEE-CIGRE task force [4] revisited and extended its classical definition of power system stability upon detailed assessment of IBR behavior in BPSs.”
BackgroundPower-flow for archipelago-based multi-terminal HVDC grids
da Silva, F. F., Irnawan, R., Mochamad, R. F., Zhang, Z., & Zhang, Q. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110274 · Cited by 6
Liu, D., Wu, K., Guo, Z., Cui, Y., Liu, W., & Zhang, J. (2024) · Frontiers in Energy Research · doi:10.3389/fenrg.2024.1342793 · Cited by 6
Xie, Z., Zhang, D., Hu, W., & Han, X. (2024) · Energies · doi:10.3390/en17081942 · Cited by 6
A transient reactive power control strategy of PV-ESS enhances the system transient stability
Liu, C., Wu, T., Zhu, J., Ran, W., Wu, Y., & Tian, A. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2024.112302 · Cited by 6
Large-Signal Modeling of Grid-Following Inverter: from Sixth-Order Model to Second-Order Model
Huang, L., Wu, C., Zhou, D., Blaabjerg, F., & He, S. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567659 · Cited by 6
“Given that wind and solar power plants are interconnected with the power system via inverters, the stability of power system is contingent upon the stability of these grid-connected inverters [4]-[6].”
BackgroundTransient Stability Analysis for Hybrid GFM-GFL Systems with Current Limit
Zhang, X., Huang, Z., Wang, Z., Li, G., Zheng, L., & Xia, S. (2024) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm51994.2024.10688760 · Cited by 6
“With the wide application of power electronic inverter interface technology, the dynamic response characteristics of power system have gradually changed from being dominated by synchronous generators to being dominated by power electronic devices [1]-[2].”
BackgroundSmall-Signal Synchronization Stability of Sequence-Decomposed Grid-Forming IBRs
Liu, Q., Liang, Y., Zhang, Z., Wang, M., & Zhao, X. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3493177 · Cited by 6
“T HE global rise in penetration levels of inverter-based resources (IBRs), such as wind and solar photovoltaic, is projected to profoundly impact the dynamic performance of the power grid [1].”
Signatures and Mechanism Analysis of Converter-Grid Subsynchronous Oscillations
Аскаров, А. Б., Bay, Y. D., Уфа, Р. А., Radko, P., Ilyushin, P., & Suvorov, A. A. (2024) · Mathematics · doi:10.3390/math12243884 · Cited by 6
Feslı, U., Özdemir, M. B., & Akın, M. (2024) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2024.101934 · Cited by 6
Eigenvalue-Oriented Data-Driven Small-Signal Stability Assessment for DC Microgrids
Deng, R., Jiang, Q., Zhou, X., Wang, Y., & Sun, M. (2024) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2024.3523868 · Cited by 6
“Additionally, due to power sharing among DERs, the DERs and loads are strongly coupled, and system instability will lead to fluctuations in all system variables, including voltage, power, and the frequency of AC equipment, which is quite different from the traditional grid [2], [3].”
Zhang, Z., Xiao, H., Liu, W., & Huang, Y. (2025) · Symmetry · doi:10.3390/sym17050629 · Cited by 6
“A large number of GFL VSCs connecting to the grid have significantly changed the characteristics of traditional power systems [4–6].”
Dynamic Model of Commercially Available Inverters With Validation Against Hardware Testing
Bountouris, P., Tzelepis, D., Abdulhadi, I., & Coffele, F. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3179667 · Cited by 6
“sampling frequency, is considered sufficient for the required modelling simulations according to [31].”
MethodHan, T., Hill, D. J., & Song, Y. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3203076 · Cited by 6
“For transmission networks, inverter dynamics enlarge the timescale of structure-dependent stability phenomena to a period from several milliseconds to tens of seconds [14].”
BackgroundSelf-citationMultimachine Stability Enhancement using Fuzzy- Logic based PSS tuning with Shunt FACTS Device
Madhusudhan, M., Pradeepa, H., Kumar, M. V. L., & Bilgundi, S. K. (2023) · Indonesian Journal of Electrical Engineering and Informatics (IJEEI) · doi:10.52549/ijeei.v11i1.3931 · Cited by 6
Short-Term Dynamic Voltage Stability Status Estimation Using Multilayer Neural Networks
Massaoudi, M., Refaat, S. S., Ghrayeb, A., & Abu‐Rub, H. (2023) · IEEE Texas Power and Energy Conference (TPEC) · doi:10.1109/tpec56611.2023.10078583 · Cited by 6
Large-Signal Stability Analysis of AC Micro-Grid Under Quadratic Droop Control
Liu, Z., Huang, L., Xia, Z., Liu, X., Han, H., Sun, Y., & Su, M. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3279351 · Cited by 6
A Data-driven Approach for the Design of Wide-Area Damping Controllers
Bernardo, R. T., Campestrini, L., Oliveira, R. C. L. F., Aquino, A. F. C., & Dotta, D. (2023) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-023-01026-0 · Cited by 6
“Regarding the smallsignal angular stability, the main challenges are stated as follows (Hatziargyriou et al., 2021): (i) different operating points can change the flows on major tie-lines, which may, in turn, affect the damping of inter-area modes; (ii) displacing large synchronous generators,…”
BackgroundQuantitative Effect of the Inertia Emulation Block of Grid-Forming Inverters on Frequency Stability
Shikuma, R., Orihara, D., Kikusato, H., Taoka, H., Kaneko, A., & Hayashi, Y. (2023) · IEEE PowerTech Conference · doi:10.1109/powertech55446.2023.10202957 · Cited by 6
“SGs have been contributing to power system stability [3].”
BackgroundSenyuk, M. D., Safaraliev, M., Pazderin, A., Pichugova, O., Zicmane, I., & Beryozkina, S. (2023) · Mathematics · doi:10.3390/math11224667 · Cited by 7
Wang, Y., Xu, S., Sun, H., & Shen, C. (2024) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2024.3410321 · Cited by 6
Impact of Passive-Components’ Models on the Stability Assessment of Inverter-Dominated Power Grids
del Giudice, D., Bizzarri, F., Grillo, S., Linaro, D., & Brambilla, A. (2022) · Energies · doi:10.3390/en15176348 · Cited by 6
Priyamvada, I. R. S., Das, S., & Chaudhuri, B. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3228940 · Cited by 6
“T HE interactions among different components of power systems are important for understanding the dynamic behaviour of the system [1].”
BackgroundInfluentialSemi-explicit multilinear modeling of a P Q open-loop controlled PV inverter in α β -frame
Kaufmann, C., Pangalos, G., Lichtenberg, G., & Gomis‐Bellmunt, O. (2023) · Energy Reports · doi:10.1016/j.egyr.2022.12.135 · Cited by 6
A New Self-Tuning Deep Neuro-Sliding Mode Control for Multi-Machine Power System Stabilizer
Gu, C., Chi, E., Guo, C., Salah, M. M., & Shaker, A. (2023) · Mathematics · doi:10.3390/math11071616 · Cited by 6
Co-optimizing transmission and BESS expansions with system strength constraints
Cerda, J. P., Rahmann, C., Moreno, R., & Moran, L. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110696 · Cited by 5
Self-citationReal-time small-signal security assessment using graph neural networks
Justin, G., & Paternain, S. (2024) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2024.101469 · Cited by 5
“This kind of stability is characterized by the system’s damping of oscillations following a disturbance or change of system topology [4].”
BackgroundLiyanage, C., Meegahapola, L. G., Nutkani, I. U., & Jalili, M. (2025) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2025.3538480 · Cited by 6
“However, this enhancement comes at the expense of inferior system strength, inertia, fault levels, and the worsening oscillation damping following the network perturbations [1].”
InfluentialPerformance Comparison of LCC and VSC HVDC Systems in Minimizing Long-Term Voltage Collapse
Fernandes, R. P., Lirio, F. L., de Oliveira, B. C., & Lima, A. C. S. (2025) · IEEE Access · doi:10.1109/access.2025.3554448 · Cited by 5
Facets of hydro power and future trends in a Nordic Context
Tome-Robles, D. J., Maurer, F., Nøland, J. K., Panwar, M., Mishra, S., & Øyvang, T. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.04.005 · Cited by 5
Ren, C., Tang, Y.-P., Gao, Y., Sun, X., Fu, K., Skoglund, M., Dong, Z. Y., Yu, H., Li, A., & Xiao, M. (2025) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2025.3574588 · Cited by 5
“However, the unpredictable and uncontrollable characteristics of renewable power introduce substantial challenges to the secure functioning of smart grid, particularly when the fluctuations in renewable power and load demand occur simultaneously [1].”
Mollaali, A., Zufferey, G., Constante‐Flores, G. E., Moya, C., Li, C., Meng, Y., & Lin, G. (2025) · Neural Networks · doi:10.1016/j.neunet.2025.107809 · Cited by 5
Optimal allocation of fast frequency response in power systems considering inertia distribution
Maureira, G. C., Rahmann, C., Palma-Behnke, R. E., & Vittal, V. (2025) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2025.101905 · Cited by 5
Self-citationAssessing the inertial response time of grid-forming converters: Estimation and optimization
Sun, L. L., Pan, Y., & Wang, H. (2025) · Electric Power Systems Research · doi:10.1016/j.epsr.2025.112470 · Cited by 5
An Evaluation Method of Renewable Energy Resources’ Penetration Capacity of an AC-DC Hybrid Grid
Li, C., Zhang, D., Liu, Z., Xiong, Y., Yu, T., Gao, Z., & Miao, S. (2022) · Energies · doi:10.3390/en15072550 · Cited by 5
An Adaptive Voltage Control Using Local Voltage Profile Mode and Similarity Ranking
Ma, H., Wang, G., Gao, X., Zou, Z., & Dong, Y. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.865151 · Cited by 5
“Long-term voltage instability is always triggered by outage of transmission and/or generation equipment after fault clearing when the load dynamics attempts to restore power consumption beyond the maximum power transfer limit (Hatziargyriou et al., 2020).”
BackgroundInfluentialMiranda, R. L., Fernandes, L. D. E. S., Araújo, D. N., Medrado, R. C., Filho, D. F. G., & Aderbal, G. M. (2023) · IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la56058.2023.10328254 · Cited by 5
“Wind and PV plants use electronic converters to interface with the grid, and unlike synchronous machines, the converters are characterized by having low or no inertia, limited short-circuit current, and reactive power supply capability, among other aspects [2] [3].”
BackgroundZhou, W., Mohammed, N., & Bahrani, B. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3376659 · Cited by 5
“This instability is primarily due to broad adverse control interactions that occur between these PLL-based GFLIs and the weak grid environments [5], [6].”
BackgroundAraúz, J., & Martínez, S. (2024) · IEEE Access · doi:10.1109/access.2024.3396331 · Cited by 5
“The increasing presence of this type of generation has forced the redefinition of the concept of ‘‘stability in power systems’’ [3], [4] and of the possible solutions.”
BackgroundXia, Y., Wei, W., Cheng, H., Li, L., Hu, Z., & Bo, Y. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.102018 · Cited by 9
Liu, Y., & Jia, R. (2024) · Engineering · doi:10.1016/j.eng.2024.05.017 · Cited by 5
Design of a Robust PID-PSS & FACTS Using Craziness Particle Swarm Optimization in Sulselrabar System
(2024) · International journal of intelligent engineering and systems · doi:10.22266/ijies2024.0831.38 · Cited by 5
Mishra, A., Mir, A. S., & Padhy, N. P. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3425576 · Cited by 5
“Thedynamicsecurityassessment Thedynamicsecurityassessment inapowersystemtypicallyinvolvesassessingtheabilityofthe systemtowithstandarangeofpotentialfaultsthatmayoccur inthepowersystemnetwork[4],[5].”
PRBS-Based Impedance Measurement Tool for Stability Analysis of Black-Box EMT Models in PSCAD
Mohammed, N., Zhou, W., Bahrani, B., Hill, D. J., & Blaabjerg, F. (2024) · International Conference on Emerging Smart Technologies and Applications (eSmarTA) · doi:10.1109/esmarta62850.2024.10638870 · Cited by 5
“Hence, the categories of IBRs, namely grid-following inverters (GFLIs) and grid-forming inverters (GFMIs), are expected to reshape future power systems dynamics, necessitating insights into instability issues for successful integration into modern grids [2].”
BackgroundSelf-citationDNP3 Implementation in a High DER Penetration Distribution System
Moldovan, D., & Ayyanar, R. (2024) · IEEE Kansas Power and Energy Conference (KPEC) · doi:10.1109/kpec61529.2024.10676137 · Cited by 5
“Today, these are being replaced by green sources like photovoltaics (PV) and wind [1], but these introduce new challenges to the grid.”
BackgroundMoutevelis, D., Roldán‐Pérez, J., Rodríguez-Ortega, P., & Prodanović, M. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3487017 · Cited by 5
“The MG formed by these elements is stable (excluding the VSM), although it is prone to low-frequency converter-driven interactions that will be analysed later in Section V-C [22].”
Sun, C., Wang, N., Ding, Y., Shang, X., & Chen, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3481907 · Cited by 5
“I N the past decades, the issue of broadband oscillation has become increasingly prominent in power system, due to the large-scale integration of renewable energy resources interfaced by power electronic converters [1].”
Fang, J., Yang, S., Xie, Z., Zhang, X., & Chang, L. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3499315 · Cited by 5
“The former interaction is formulated as the weak-grid problem [1].”
InfluentialLu, S., Wu, M., Liu, J., Wang, H., Yang, L., Liu, Q., Yang, J., & Sui, Y. (2024) · IET Renewable Power Generation · doi:10.1049/rpg2.13174 · Cited by 5
Aspects of Relevance of Hybrid Power Plants in Control and Stability of Weak Grids
Shahnazian, F., Das, K., Yan, R., & Sørensen, P. E. (2024) · Energies · doi:10.3390/en17246353 · Cited by 5
“This can be further classified into small and large disturbance voltage stability [21].”
Salleh, Z. M. T., Alsammak, A. N. B., & Mohammed, H. A. (2024) · Journal Européen des Systèmes Automatisés · doi:10.18280/jesa.570603 · Cited by 5
Liu, K., Chen, Z., Li, X., & Gao, Y. (2025) · Energies · doi:10.3390/en18061317 · Cited by 5
Barbosa, J. P. P., Filho, J. A. P., Ramos, R. A., & Alberto, L. (2025) · IEEE Access · doi:10.1109/access.2025.3555935 · Cited by 5
“Recent work defines stability as encompassing not only angle, frequency, and voltage stability [6] but also resonance and converter-driven stability [7].”
A Dynamic Similarity Index for Assessing Voltage Source Behaviour in Power Systems
Alican, O., Moutevelis, D., Arévalo-Soler, J., Collados‐Rodríguez, C., Amorós, J., Gomis‐Bellmunt, O., Cheah-Mañé, M., & Prieto‐Araujo, E. (2025) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2025.3628350 · Cited by 5
“…(cid:2) Range 2: 20-40 Hz - Low frequency (cid:2) Range 3: 40-100 Hz - Converter-driven (cid:2) Range 4: 100-1000 Hz - Fast interaction This range selection was chosen due to the current understanding and classification between dynamic phenomena in power systems and their timescale separation [43].”
Ribeiro, R., Cerveira, A., & Baptista, J. (2021) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet52533.2021.9698750 · Cited by 5
Optimal Sizing of Battery Energy Storage System for Grid Stability in Western Kenya
Ngala, M. O., Opana, S., Charles, J. K., Nabaala, A., & Wachira, K. (2022) · IEEE PES/IAS PowerAfrica Conference (PowerAfrica) · doi:10.1109/powerafrica53997.2022.9905373 · Cited by 5
“Power system stability is its ability to regain operating balance after being subjected to a physical disturbance with most system variables bounded so that the entire system remains practically intact [1].”
BackgroundThe Impact of Frequency Support by Wind Turbines on the Small-Signal Stability of Power Systems
Pepiciello, A., Domínguez‐García, J. L., & Vaccaro, A. (2022) · Energies · doi:10.3390/en15228470 · Cited by 5
Hilawie, A., & Shewarega, F. (2022) · EAI Endorsed Transactions on Energy Web · doi:10.4108/ew.v9i40.141 · Cited by 5
“Voltage instability is characterized by uncontrolled voltage decline at load buses regardless of the amount of reactive power compensation switched to [1-3].”
BackgroundXue, Y., Zhang, Z., Hua, W. X., Wang, G., Xu, Z. G., & Dong, W. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12785 · Cited by 5
Zhu, J., Zhou, B., Qiu, Y., Zang, T., Zhou, Y., Chen, S., Dai, N., & Luo, H. (2023) · Energies · doi:10.3390/en16165938 · Cited by 5
Comparison of Voltage Stability Indices Based on Synchronized PMU Measurements
de Souza, V. M., de Brito, H. R., & Uhlen, K. (2023) · International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest57387.2023.10257545 · Cited by 5
“In recent years, these developments have reinforced the need to update definitions of previously well-known stability phenomena, with the introduction of two new categories of stability: resonance and converter-driven [1].”
BackgroundGu, H., Jiao, Z., & Xiang, Y. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3321091 · Cited by 5
“During the device plug-in and -out, small-perturbation stability issues may arise due to the poor tuning of one or more equipment controllers and inadequate operating parameters [4], [5].”
BackgroundXing, Y., Zhang, G., Wang, B., Li, J., Bamisile, O., Cai, D., & Huang, Q. (2024) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-024-01820-z · Cited by 5
Data creation techniques and data-oriented models for dynamic security assessment of power system
Singh, M. P., & Sinha, N. (2024) · Electrical Engineering · doi:10.1007/s00202-024-02319-6 · Cited by 5
“…must ensure voltage and frequency stability within acceptable limits while making optimal use of power system resources (generation, transmission, and distribution assets) and eliminating cascading system failures while ensuring supply security in accordance with regulatory compliances [1].”
Thuý, H. L. T., Sanseverino, E. R., Nguyen, Q.-N., Silvestre, M. L. D., Favuzza, S., Nguyen, D. Q., & Musca, R. (2024) · Renewable energy focus · doi:10.1016/j.ref.2024.100638 · Cited by 5
“The suggestions about surveying the electricity security of power systems are provided in [39,40,45 – 48], see Fig.”
BackgroundGómez-Ramírez, G. A., García-Santander, L., Morales, J., Zubiaga, M., & Meza, C. (2024) · Energies · doi:10.3390/en17235878 · Cited by 5
Robin, M., Renedo, J., Gonzalez‐Torres, J. C., García‐Cerrada, A., Rouco, L., Benchaib, A., & García-González, P. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.110467 · Cited by 5
Metadata
- Authors
- Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., Pourbeik, P., Sanchez-Gasca, J., Stankovic, A., Van Cutsem, T., Vittal, V., & Vournas, C.
- Affiliations
- National Technical University of Athens (GR)
- University of Chile (CL)
- Iowa State University (US)
- University of Duisburg-Essen (DE)
- University of Hong Kong (HK)
- University of Michigan (US)
- Hydro-Québec (CA)
- Imperial College London (GB)
- General Electric (United States) (US)
- Arizona State University (US)
- ORCID
- Venue
- IEEE Transactions on Power Systems
- Published
- 2021-07
- Volume
- 36
- Issue
- 4
- Pages
- 3271-3281
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3110874572
- Cited by
- 1,244
- References
- 89
- Citations by year
- 2026: 242 · 2025: 286 · 2024: 274 · 2023: 237 · 2022: 152 · 2021: 52
- FWCI
- 37.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Power Systems (publishedVersion, cc-by)
- Open Repository and Bibliography (University of Liège) (submittedVersion, cc-by)
- Research Explorer (The University of Manchester) (submittedVersion, cc-by)
- Universidad de Chile (submittedVersion, cc-by-nc-nd)
- Funders
- Engineering and Physical Sciences Research Council (EP/T021713/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- power system stability, stability definitions, stability classification, converter-interfaced generation, power devices, transmission device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
![Fig. 1 Power system times scales [3].](https://figures.cochat.ai/paper-figures/164b0e6732b447d6b5ecb5927b7f989c/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-1.png)
![Fig. 2 Classification of power system stability [3].](https://figures.cochat.ai/paper-figures/a79bfd894fd8407790c6b5a89935f15e/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-2.png)
![Fig. 3 An illustration of power system frequency response to a major loss of generation. (IEEE © 2013, reproduced from [32])](https://figures.cochat.ai/paper-figures/d327b48f98464ab6ba883eb6f355f691/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-3.png)