Definition and Classification of Power System Stability – Revisited & Extended
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Since the publication of the original paper on power system stability definitions in 2004, the dynamic behavior of power systems has gradually changed due to the increasing penetration of converter interfaced generation technologies, loads, and transmission devices. In recognition of this change, a Task Force was established in 2016 to re-examine and extend, where appropriate, the classic definitions and classifications of the basic stability terms to incorporate the effects of fast-response power electronic devices. This paper based on an IEEE PES report summarizes the major results of the work of the Task Force and presents extended definitions and classification of power system stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“AI approaches, which mimic human thought, may be helpful [87]: they mentioned in their study that recent developments include using ANN to maintain steady-state security and FL applications for determining the reliability of power systems using the interrupted energy assessment rate given in [88].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [87]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Self-citationGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 1×
“The vast majority of large-scale CIGs use voltage-source converters [11], [12], or some derivative thereof, allowing designs that offer full four-quadrant control.”
BackgroundDesign and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402 · cited 1×
“The resonance of an inverter filter can also be triggered by the control of the inverter itself or by interactions with nearby controllers [76].”
BackgroundVoltage‐Sourced Converters in Power Systems: Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Wiley eBooks · doi:10.1002/9780470551578 · Cited by 2,264
Voltage Stability of Electric Power Systems
Cutsem, T., & Vournas, C. (1998) · Springer eBooks · doi:10.1007/978-0-387-75536-6 · Cited by 2,036
Self-citationKroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367 · cited 1×
“5) Converter-driven Stability: The dynamic behavior of CIG is clearly different from conventional synchronous generators, due to the predominant VSC interface with the grid [70].”
BackgroundHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 1×
“the electromagnetic transients of the network, which may lead to unstable power system oscillations over a wide frequency range [71].”
BackgroundWind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Research works printed but not linked: 11
- P. Pourbeik and J. K. Petter, "Modeling and validation of battery energy storage systems using simple generic models for power system stability studies," Cigre Sci. Eng., no. 9, pp. 63-72, Oct. 2017.
- Dynamic Models for Turbine-Governors in Power System Studies, IEEE Power and Energy Society, Tech. Rep. PES -TR1, Jan. 2013. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTR1.html)
- P. M. Anderson and R. G. Farmer, Series compensation of power systems. Encinitas, CA, USA: PBLSH, 1996.
- F. Milano, F. Dörfler, G. Hug, D. J. Hill, and G. Verbic, "Foundations and challenges of low-inertia systems," in 20th Power Systems Computation Conference (PSCC), Dublin, Ireland, 2018.
- Stability definitions and characterization of dynamic behavior in systems with high penetration of power electronic interfaced technologies, IEEE Power and Energy Society, Tech. Rep. PES- TR77, May 2020. (available on-line: https://resourcecenter.ieee- pes.org/technical-publications/technical- reports/PES_TP_TR77_PSDP_stability_051320.html)
- Contribution to Bulk System Control and Stability by Distributed Energy Resources Connected at Distribution Network, IEEE Power and Energy Society, Tech. Rep. PES-TR22, Jan. 2017. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PESTRPDFMRH0022.html)
- Microgrid Stability, Definitions, Analysis, and Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR66, Jun. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical- publications/technical-reports/PES_TR0066_062018.html)
- North American Electric Reliability Corporation (NERC), "Integrating inverter -based resources into low short circuit strength systems: reliability guideline," Reliability Guideline, Dec. 2017.
- T. Souxes and C. Vournas, "System Stability Issues Involving Distributed Sources under Adverse Network Conditions," Bulk Power Systems Dynamics and Control -X (IREP), Porto, Portugal, Sept. 2017.
- P. Pourbeik, S. Soni, A. Gaikwad, and V. Chadliev, "Providing primary frequency response from photovoltaic power Plants," in CIGRE Symposium 2017, Dublin, Ireland, 2017.
- Impact of Inverter Based Generation on Bulk Power System Dynamics and Short-Circuit Performance, IEEE Power and Energy Society, Tech. Rep. PES -TR68, Jul. 2018. (available on-line: https://resourcecenter.ieee-pes.org/technical-publications/technical- reports/PES_TR_7-18_0068.html)
Cited by
Items 101–200 of 1,000
Power System Stability Analysis From Cyber Attacks Perspective
Semertzis, I., Stefanov, A. I., Presekal, A., Kruimer, B., Rueda, J. L., & Pálenský, P. (2024) · IEEE Access · doi:10.1109/access.2024.3443061 · Cited by 39
Ren, C., Dong, Z. Y., Yu, H., Xu, M., Xiong, Z., & Niyato, D. T. (2024) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2024.3485878 · Cited by 39
Machine Learning Accelerated Real-Time Model Predictive Control for Power Systems
Hossain, R. R., & Kumar, R. (2023) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2023.123135 · Cited by 34
Alhelou, H. H., Bahrani, B., Ma, J., & Hill, D. J. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3322434 · Cited by 34
“…(DG) units in their distribution levels, like Australia’s power system, due to the fact that the source of uncertainties, unknown inputs, and power variations in such systems would be related to both the demand-side and the power generation-side [8], [9].”
BackgroundSelf-citationSupport Vector Machines for Predicting the Impedance Model of Inverter-Based Resources
Mohammed, N., Zhou, W., Bahrani, B., & Hill, D. J. (2024) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2024.3378200 · Cited by 38
“I N THE dynamic landscape of modern power systems, a notable transformation is occurring wherein inverter-based resources (IBRs) are progressively overtaking the roles traditionally held by synchronous generators [1], [2].”
BackgroundSelf-citationA method for monitoring the load margin of power systems under load growth variations
Bento, M. E. C. (2022) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2022.100677 · Cited by 34
Bifurcations of Grid-Following Rectifiers and Routes to Voltage Instability in Weak AC Grids
Yang, J., Tse, C. K., Huang, M., & Liu, D. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3179287 · Cited by 34
Wiegel, F., Wachter, J., Kyesswa, M., Mikut, R., Waczowicz, S., & Hagenmeyer, V. (2022) · at - Automatisierungstechnik · doi:10.1515/auto-2022-0018 · Cited by 35
“Since the laboratory can be operated decoupled from the public grid, grid control strategies can be studied and evaluated in regions of critical stability [18] without the risk of large-scale blackouts.”
BackgroundZhang, R., Yao, W., Shi, Z., Ai, X., Tang, Y., & Wen, J. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3220569 · Cited by 39
“In simulation analysis, it is a vital step to analyze the stability [7], [24] and identify the dominated instability mode (DIM) if unstable, that is, to determine whether the instability mode is dominant by transient rotor angle instability or short-term voltage instability [8], [9], [10], [11].”
BackgroundRouhanian, A., Aliamooei-Lakeh, H., Aliamooei-Lakeh, S., & Toulabi, M. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2023.109511 · Cited by 33
DNN Assisted Projection Based Deep Reinforcement Learning for Safe Control of Distribution Grids
Zhang, M., Guo, G., Zhao, T., & Xu, Q. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3336614 · Cited by 40
A power system stability assessment framework using machine-learning
Meridji, T., Joós, G., & Restrepo, J. (2021) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108981 · Cited by 33
Enhancing Microgrid Stability and Energy Management: Techniques, Challenges, and Future Directions
Safder, M. U., Sanjari, M. J., Hamza, A., Garmabdari, R., Hossain, M. A., & Lu, J. (2023) · Energies · doi:10.3390/en16186417 · Cited by 35
Si, W., Fang, J., Chen, X., Xu, T., & Goetz, S. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3477492 · Cited by 32
“Transient angle stability refers to the ability to remain synchronized with the grid or other power sources after being subjected to a large disturbance [18].”
Lacerda, V. A., Prieto‐Araujo, E., Cheah-Mañé, M., & Gomis‐Bellmunt, O. (2022) · IEEE Access · doi:10.1109/access.2022.3174958 · Cited by 32
Toward Online Power System Model Identification: A Deep Reinforcement Learning Approach
Hu, J., Wang, Q., Ye, Y., & Tang, Y. P. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3180415 · Cited by 33
Region of Attraction Estimation for Power Systems With Multiple Integrated DFIG-Based Wind Turbines
Liu, Y., Yao, H., Di, P., Qin, Y., Ma, Y., Alkahtani, M. S., & Hu, Y. (2025) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2025.3579018 · Cited by 31
External Inertia Emulation Controller for Grid-Following Power Converter
Lai, N. B., Tarrasó, A., Baltas, G. N., Marin, L., & Rodríguez, P. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3108350 · Cited by 31
“, between 1 and 10 s [23], which is not so demanding in terms of control bandwidth.”
BackgroundYakout, A. H., Sabry, W., Abdelaziz, A. Y., Hasanien, H. M., AboRas, K. M., & Kotb, H. (2021) · Alexandria Engineering Journal · doi:10.1016/j.aej.2021.11.011 · Cited by 31
Ren, C., Yuan, H., Li, Q., Zhang, R., & Xu, Y. H. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3223166 · Cited by 31
Mohale, V., Chelliah, T. R., & Hote, Y. V. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3221070 · Cited by 31
“In view stability, IEEE has defined the various stability issues in the power system [21] and recently SSCI has been considered by most of the policy makers and grid authorities due to incidents reported in [22], [23].”
BackgroundCapitanescu, F. (2023) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2023.3247053 · Cited by 31
Comparison of Homoclinic Bifurcations Between Grid-Following and Grid-Forming Converters
Yang, J., Tse, C. K., Huang, M., Liu, D., Liu, C. C., & Fu, X. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3285982 · Cited by 31
Transient Stability Analysis with Physics-Informed Neural NetworksPreprint
Stiasny, J., Misyris, G. S., & Chatzivasileiadis, S. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.13638 · Cited by 31
“The proliferation of converter-connected devices and the continuously increasing penetration of renewable sources, however, add significant complexity to an already complex procedure [1].”
BackgroundÁvila-Martínez, R. E., Renedo, J., Rouco, L., García‐Cerrada, A., Sigrist, L., Qoria, T., & Guillaud, X. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3199650 · Cited by 30
Power system inertia estimation method based on maximum frequency deviation
Wang, B., Sun, H., Li, W., Yang, C. R., Wei, W., Zhao, B., & Xu, S. (2021) · IET Renewable Power Generation · doi:10.1049/rpg2.12367 · Cited by 30
Dimoulias, S. C., Kontis, E. O., & Papagiannis, G. K. (2022) · Energies · doi:10.3390/en15207767 · Cited by 30
“This shift towards converterinterfaced generation progressively reduces the overall inertia levels [14], modifying powersystem dynamics, and also raising frequency stability issues [15,16].”
BackgroundDeep-Learning-Aided Voltage-Stability-Enhancing Stochastic Distribution Network Reconfiguration
Huang, W., & Zhao, C. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3286406 · Cited by 33
“The deep learning method to be proposed shortly can predict the voltage stability index I v from the SDNR decisions, for various types of voltage stability defined in [25].”
MethodGuerreiro, G. M. G., Sharma, R., Martin, F., Ghimire, P., & Yang, G. (2023) · IEEE Access · doi:10.1109/access.2023.3288610 · Cited by 30
“these effects for different aspects [6].”
Enhancing Dynamic Security Assessment in Smart Grids Through Quantum Federated Learning
Ren, C., Dong, Z. Y., Skoglund, M., Gao, Y., Wang, T., & Zhang, R. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3486070 · Cited by 29
“A. Background D YNAMIC security assessment (DSA) in an intelligent power grid is crucial for evaluating the stability of an electric power system under a range of credible contingencies [1], [2].”
Comprehensive Review of PMU Applications in Smart Grid: Enhancing Grid Reliability and Efficiency
Yu, S. S., Rahman, M. S., Zhang, G., Meraj, S. T., & Trinh, H. M. (2025) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2025.000129 · Cited by 29
Exploration of Artificial-intelligence Oriented Power System Dynamic Simulators
Xiao, T., Chen, Y., Wang, J., Huang, S., Tong, W., & He, T. (2023) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000099 · Cited by 29
Review of Wide-Area Controllers for Supporting Power System Stability
Mira-Gebauer, N. F., Rahmann, C., Álvarez-Malebrán, R., & Vittal, V. (2023) · IEEE Access · doi:10.1109/access.2023.3237576 · Cited by 29
“These works were classified based on the kind of stability they address according to [14], as shown in Table 2.”
BackgroundSelf-citationMarquez, J. L. A., Al-Ja’Afreh, M. A. A., Mokryani, G., Kabir, S., Campean, F., Dao, C. D., & Riaz, S. (2023) · Energy Reports · doi:10.1016/j.egyr.2023.02.082 · Cited by 29
Kim, J.-K., Kang, J.-S., Shim, J. W., Kim, H., Shin, J., Kang, C., & Hur, K. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3284890 · Cited by 29
Zhang, G., Li, J., Xing, Y., Bamisile, O., & Huang, Q. (2023) · ISA Transactions · doi:10.1016/j.isatra.2023.09.018 · Cited by 30
Liu, J., Xia, Y., Wei, W., Feng, Q., & Yang, P. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3381148 · Cited by 29
“A HIGH proportion of renewable energy access has led to the emergency and development of converter-dominant power grids [1], and consequently reduces the grid inertia and deteriorates the stability [2], [3].”
BackgroundWang, P., Li, S., Wang, W., & Xu, D. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3462908 · Cited by 29
“Compared to SGs with an overcurrent capability of 6-8 p.u., power converters have an awfully limited overcurrent capability of about 1.5 p.u. [15].”
InfluentialHuang, L., & Blaabjerg, F. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3516214 · Cited by 28
“Namely, the GFL inverter tends to be unstable during a severe grid fault when the SCR is lower than 2 or 1.5, which may threaten the stability of the whole power system [8].”
InfluentialLv, Z., Wang, B., Guo, Q., Sun, H., Zhao, H., & Jiang, M. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3226509 · Cited by 28
“Giventheinteractionofthemulti-infeed LCC-HVDCs,theshort-termvoltagestabilityproblemsnear theconverterstationsbecomemoreprominent[8].”
Transient Stability Assessment Using Deep Transfer Learning
Kim, J., Lee, H., Kim, S., Chung, S., & Park, J. H. (2023) · IEEE Access · doi:10.1109/access.2023.3320051 · Cited by 30
Joint Transient Angle and Voltage Stability Analysis and Enhancement of Grid-Forming Converters
Si, W., Li, W., Tashakor, N., & Fang, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3454767 · Cited by 27
“According to transient instability mechanisms, the transient stability problems of grid-forming converters comprise two major types — transient angle and voltage stability problems [16], [17].”
Revisit power system dispatch: Concepts, models, and solutions
Yang, Z., Yong, P., & Xiang, M. (2023) · iEnergy · doi:10.23919/ien.2023.0010 · Cited by 32
Liu, S., Luo, W., Zhou, Y., Chen, K., Zhang, Q., Xu, H., Guo, Q., & Song, M. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3298007 · Cited by 36
“P OWER systems are complex nonlinear physical systems with high uncertainty [1].”
BackgroundReview of Operational Challenges and Solutions for DER Integration with Distribution Networks
Javed, A. H., Nguyen, P. H., Morren, J., & Slootweg, J. G. (2021) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec50034.2021.9548198 · Cited by 34
Bento, M. E. C. (2023) · Results in Control and Optimization · doi:10.1016/j.rico.2023.100258 · Cited by 26
Large-Signal Stability Analysis of Inverter-Based AC Microgrids: A Critical and Analytical Review
Hosseinpour, H., MansourLakouraj, M., Benidris, M., & Livani, H. (2023) · IEEE Access · doi:10.1109/access.2023.3321834 · Cited by 26
“…differences between microgrids and conventional power grids are itemized as follows : The microgrid includes inverters and other power electronics devices, making their dynamic response faster than that in transmission power systems equipped with mechanical components used in the generators [32].”
BackgroundXu, J., Ling, Z., Luo, Y., Kan, J., Diao, H., & Xie, S. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3444281 · Cited by 25
Saadatmand, M., Gharehpetian, G. B., Kamwa, I., Siano, P., Guerrero, J. M., & Alhelou, H. H. (2021) · Energies · doi:10.3390/en14185983 · Cited by 25
Self-citationUnified Power Quality Management for Traction Substation Groups Connected to Weak Power Grids
Chen, M., Chen, Y., Chen, Y., Dai, X., & Li, L. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3147067 · Cited by 25
“For example, [10] emphasizes the characteristics of the”
BackgroundChang, M., Wang, X., Lv, X., & Kong, R. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3200994 · Cited by 25
“line impedance when analyzing the instability in power electronic-based power system [21], [22].”
BackgroundZuluaga, C. D., Jaramillo, A. V., & Saldarriaga-Zuluaga, S. D. (2022) · Energies · doi:10.3390/en15207646 · Cited by 25
Universal Grid-Forming Method for Future Power Systems
Laaksonen, H. J. J. (2022) · IEEE Access · doi:10.1109/access.2022.3231479 · Cited by 28
“ity issues will be substantial in future power systems and requires also new stability definitions [48].”
BackgroundRadwan, M. M., Azmy, A. M. R., Ali, G. E. M., & ELGebaly, A. E. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109056 · Cited by 26
Majumder, S., Vosughi, A., Mustafa, H. M., Warner, T. E., & Srivastava, A. K. (2023) · IEEE Access · doi:10.1109/access.2023.3278281 · Cited by 29
“Additionally, the new IBRs have vastly different dynamics than traditional synchronous machine-based generators [22].”
BackgroundRen, C., Wang, T., Yu, H., Xu, Y. H., & Dong, Z. Y. (2023) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2023.3293253 · Cited by 25
“Thus, it is significant to maintain high stability in smart cyber-physical grids for reliable, secure, and continuous electricity supply to the customers [2].”
BackgroundDesign and Performance Evaluation of a Hybrid Active Power Filter Controller
Herman, L., Knez, K., & Blažič, B. (2024) · Energies · doi:10.3390/en17112492 · Cited by 24
Grand challenges of wind energy science – meeting the needs and services of the power system
O’Malley, M., Holttinen, H., Cutululis, N. A., Vrana, T. K., King, J., Gevorgian, V., Wang, X., Najafabadi, F. R., & Hadjileonidas, A. (2024) · Wind energy science · doi:10.5194/wes-9-2087-2024 · Cited by 28
“Similarly for other host technologies, power-electronics-related solutions will be developed for IBRs, such as solar PV and battery storage, and this blurring of the boundaries between the technologies is to be There are also regulatory, subsidy, commercial, and market advantages that can be very system specific.”
BackgroundInfluentialSenyuk, M. D., Beryozkina, S., Gubin, P. Y., Dmitriev, S. A., Kamalov, F., Safaraliev, M., & Zicmane, I. (2022) · Mathematics · doi:10.3390/math10213949 · Cited by 24
Machado, S. D. J. M., da Silva, S. A. O., Monteiro, J. R. B. D. A., Sampaio, L. P., & de Oliveira, A. A. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3222630 · Cited by 24
Voltage stability analysis of grid-forming converters with current limitation
Liemann, S., & Rehtanz, C. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110820 · Cited by 26
Trend Analysis of Cross-Border Electricity Trading in Pan-European Network
Venizelou, V., & Poullikkas, A. (2024) · Energies · doi:10.3390/en17215318 · Cited by 23
Davari, M., Qasem, O., Gao, W., Blaabjerg, F., Kotsampopoulos, P. C., Lauss, G. F., & Hatziargyriou, N. D. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3426038 · Cited by 23
“…the model of interest digitally simulated on a real-time digital simulation platform—the time constants/responses of IBRs and those of power amplifiers can get closer (e.g., see [5], [6], [7], [8], [9]), thereby resulting in the inaccuracy of the PHIL-simulation-based testing of IBR-dominated grids.”
Self-citationAbudyak, Y., Rezaei, M. H., Abdelnabi, A. A. B., Rizi, H. S., Batarseh, I., & Huang, A. Q. (2026) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2026.3654526 · Cited by 25
“3 is implemented to constrain the current reference within a range that ensures the safe operation of the inverter switches, in accordance with their thermal limits, typically between 1.2 to 1.4 times the inverter’s rated current [81].”
InfluentialNetto, M., Krishnan, V. K., Zhang, Y. Y. C., & Mili, L. (2021) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12336 · Cited by 23
“The consideration of other notions of stability—particularly frequency, resonance, and converter-driven stability [137]—is a gap in the literature and an opportunity for future development.”
BackgroundMethodConditions of Existence and Uniqueness of Limit Cycle for Grid-Connected VSC With PLL
Li, Y., Lu, Y., Tang, Y., & Du, Z. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3238000 · Cited by 23
“Traditional synchronous generators (SGs) rely on the natural power-angle property to maintain the synchronization with the power grid during the large disturbance [1].”
BackgroundPower Swing in Systems With Inverter-Based Resources—Part II: Impact on Protection Systems
Nasr, M., & Hooshyar, A. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3382843 · Cited by 23
“It is worth noting that the oscillations associated with the inverters’ outer control loops, including the dc-link voltage control loop discussed in [1], fall under the category of low-frequency oscillations [14].”
BackgroundYin, Y., Jiang, X., Huang, D., Li, Y., Yue, M., & Zhao, T. (2024) · IEEE Access · doi:10.1109/access.2024.3384457 · Cited by 23
“Power system stability has seen extensive efforts in the past decade [2], [3], [4].”
BackgroundFast Transient Stability Assessment of Power Systems Using Optimized Temporal Convolutional Networks
Massaoudi, M., Zamzam, T., Eddin, M. E., Ghrayeb, A., Abu‐Rub, H., & Refaat, S. S. (2024) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2024.3426334 · Cited by 23
“With the constantly expanding scale of modern power systems, the existing power infrastructure encounters unprecedented changes in the wake of extensive penetration of renewable energy sources (RESs) [1].”
BackgroundMachine learning-based inertia estimation in power systems: a review of methods and challenges
Diggikar, S., Patil, A., Satyapal, K. S., & Samad, K. (2025) · Energy Informatics · doi:10.1186/s42162-025-00496-7 · Cited by 25
“The growing global energy demand, combined with the limited supply of conventional energy resources and escalating ecological concerns, has driven a substantial transition toward RES, particularly focusing on IBGs such as wind and solar photovoltaic (PV) power plants [1].”
Chatterjee, K., Samanta, S., & Chaudhuri, N. R. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3215929 · Cited by 22
“The instability, in this case, primarily stems from the interaction between the fast-acting PLL and the inner current control loops in the VSC [24], [25].”
BackgroundLi, Y., Yao, W., Zhao, Y., Huang, W. K., Zhai, S., Li, W., Wen, J., & Xia, Y. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109847 · Cited by 22
Lv, Z., Wang, B., Guo, Q., Zhao, H., Wang, Z., & Sun, H. (2024) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2024.3401742 · Cited by 23
“Meanwhile, the nodes adjacent to the generator also pay more attention to the generator nodes, such as nodes 2, 22 and 23.”
InfluentialSmall-signal stability analysis of uncertain power systems: A comprehensive survey
Pepiciello, A., & Domínguez‐García, J. L. (2024) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2024.114576 · Cited by 22
Fault Current Limiting and Grid Code Compliance for Grid-Forming Inverters—Part I: Problem Statement
Azizi, A., & Hooshyar, A. (2024) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2024.3424405 · Cited by 23
“This instability, arising from the poor design of the inverter’s control system, is categorized as converter-driven instability in the recent classification of power system stability [34].”
BackgroundStability Assessment of Low-Inertia Power Systems: A System Operator Perspective
Hurtado, M., Jafarian, M. J., Kërçi, T., Tweed, S., Escudero, M. V., Kennedy, E., & Milano, F. (2024) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm51994.2024.10688904 · Cited by 21
“The power system community have recently updated the classification of power system stability to account for the changing dynamic behavior mainly due to the introduction of such technologies [1].”
BackgroundWang, K., Song, Q., Liu, W.-H., Zhao, B., & Zhang, P. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3479726 · Cited by 24
“For instance, reactive power and dynamic voltage support has been widely viewed as the countermeasure for fault-induced delayed voltage recovery and short-term voltage instability [19].”
Stability tool for electric power systems with a high penetration of electronic power converters
Serrano-Jiménez, D., Unamuno, E., Gil‐de‐Muro, A., Aragon, D. A., Ceballos, S., & Barrena, J. A. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108115 · Cited by 21
Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems
Hou, J., Wang, J., Song, Y., Sun, W., & Hou, Y. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3199366 · Cited by 26
Xue, Y., Zhang, Z., Zhang, N., Hua, W. X., Wang, G., & Xu, Z. G. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109017 · Cited by 21
Cui, Z., Hu, W., Zhang, G., Huang, Q., Chen, Z., & Blaabjerg, F. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3315538 · Cited by 21
“Inevitably, there are random time delays in the wide-area measurement signal, and ignoring this phenomenon will affect the accuracy of the identification and thus mislead the security analysis [6].”
BackgroundClassification of Converter-Driven Stability and Suitable Modeling and Analysis Methods
Zuromski, C., Babazadeh, D., & Becker, C. U. (2024) · IEEE Access · doi:10.1109/access.2024.3388098 · Cited by 21
Probabilistic Risk Evaluation of Microgrids Considering Stability and Reliability
Song, Y., Sahoo, S., Yang, Y., & Blaabjerg, F. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3278037 · Cited by 21
“induced converter stability [7], [8], which is typical for droopdominated microgrids.”
BackgroundA Comprehensive Review on Stability Analysis of Hybrid Energy System
Kumari, N., Tran, B., Sharma, A. P., & Alahakoon, D. (2025) · Sensors · doi:10.3390/s25102974 · Cited by 20
Bharati, A. K., Ajjarapu, V., Du, W., & Liu, Y. (2022) · IEEE Systems Journal · doi:10.1109/jsyst.2022.3218117 · Cited by 20
“The D-IBR integration and changing distribution grid is leading to new behavior and manifestation of new phenomenon in the power gird that has led to an update of the classification and definitions of power system stability [11].”
BackgroundSelf-citationSimultaneous Assessment of Multiple Aspects of Stability of Power Systems With Renewable Generation
Wang, M., & Milanović, J. V. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3241862 · Cited by 20
“2) Transient stability as another component of rotor angle stability, is more related to the sufficient synchronising torque [1].”
BackgroundInfluentialControl Design of Passive Grid-Forming Inverters in Port-Hamiltonian Framework
Kong, L., Xue, Y. S., Qiao, L., & Wang, F. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3319966 · Cited by 20
Improving grid strength in a wide‐area transmission system with grid forming inverters
Mayer, P. F., Gordon, M., Huang, W., & Hardt, C. (2022) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12498 · Cited by 20
Resilient Wide-Area Damping Controller Design Using Crow Search Algorithm
Bento, M. E. C. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.04.154 · Cited by 20
Continuous-time echo state networks for predicting power system dynamics
Roberts, C., Lara, J. D., Henríquez-Auba, R., Bossart, M., Anantharaman, R., Rackauckas, C., Hodge, B. S., & Callaway, D. S. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108562 · Cited by 23
Giannuzzi, G. M., Mostova, V., Pisani, C., Tessitore, S., & Vaccaro, A. (2022) · Energies · doi:10.3390/en15218064 · Cited by 20
Xu, Y. H., Chi, Y., & Yuan, H. (2023) · Wiley eBooks · doi:10.1002/9781119848899.ch1 · Cited by 20
Benedetti, L. I., Paspatis, A., Papadopoulos, P. N., Egea‐Àlvarez, A., & Hatziargyriou, N. D. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110813 · Cited by 19
Self-citationLoad Margin Assessment of Power Systems Using Artificial Neural Network and Genetic Algorithms
Bento, M. E. C. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.04.155 · Cited by 19
Alves, E. F., Polleux, L., Guérassimoff, G., Korpås, M., & Tedeschi, E. (2023) · IEEE Access · doi:10.1109/access.2023.3261805 · Cited by 19
“post-disturbance), which is the definition of frequency stability given in [29] and in Section II-A.”
BackgroundNeamah, N. M., AbuHussein, A., Hossam‐Eldin, A. A., Alghamdi, S. M., & AboRas, K. M. (2023) · IEEE Access · doi:10.1109/access.2023.3277202 · Cited by 19
“that modern power systems must contend with [1], [2].”
BackgroundSafavizadeh, A., Ebrahimi, S., & Jatskevich, J. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109754 · Cited by 19
Rangarajan, S. S., Collins, E. R., & Senjyu, T. S. (2024) · Clean Technologies · doi:10.3390/cleantechnol6030051 · Cited by 20
“Hence, at the peak of the system voltage, the capacitors do not contribute any current [59,60].”
BackgroundResearch Methods for Transient Stability Analysis of Power Systems under Large Disturbances
Wu, H., Li, J., & Yang, H. B. (2024) · Energies · doi:10.3390/en17174330 · Cited by 19
Virtual Inertia Scheduling (VIS) for Microgrids With Static and Dynamic Security Constraints
She, B., Li, F. F., Wang, J., Cui, H., Wang, X., & Bo, R. (2024) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2024.3481239 · Cited by 19
“They quantify the ability of a power grid, for a given initial operating condition, to regain a state of operating equilibrium after being subjected to a physical disturbance, with most system variables bounded so that practically the entire system remains intact [25].”
Metadata
- Authors
- Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., Pourbeik, P., Sanchez-Gasca, J., Stankovic, A., Van Cutsem, T., Vittal, V., & Vournas, C.
- Affiliations
- National Technical University of Athens (GR)
- University of Chile (CL)
- Iowa State University (US)
- University of Duisburg-Essen (DE)
- University of Hong Kong (HK)
- University of Michigan (US)
- Hydro-Québec (CA)
- Imperial College London (GB)
- General Electric (United States) (US)
- Arizona State University (US)
- ORCID
- Venue
- IEEE Transactions on Power Systems
- Published
- 2021-07
- Volume
- 36
- Issue
- 4
- Pages
- 3271-3281
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3110874572
- Cited by
- 1,244
- References
- 89
- Citations by year
- 2026: 242 · 2025: 286 · 2024: 274 · 2023: 237 · 2022: 152 · 2021: 52
- FWCI
- 37.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Power Systems (publishedVersion, cc-by)
- Open Repository and Bibliography (University of Liège) (submittedVersion, cc-by)
- Research Explorer (The University of Manchester) (submittedVersion, cc-by)
- Universidad de Chile (submittedVersion, cc-by-nc-nd)
- Funders
- Engineering and Physical Sciences Research Council (EP/T021713/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- power system stability, stability definitions, stability classification, converter-interfaced generation, power devices, transmission device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
![Fig. 1 Power system times scales [3].](https://figures.cochat.ai/paper-figures/164b0e6732b447d6b5ecb5927b7f989c/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-1.png)
![Fig. 2 Classification of power system stability [3].](https://figures.cochat.ai/paper-figures/a79bfd894fd8407790c6b5a89935f15e/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-2.png)
![Fig. 3 An illustration of power system frequency response to a major loss of generation. (IEEE © 2013, reproduced from [32])](https://figures.cochat.ai/paper-figures/d327b48f98464ab6ba883eb6f355f691/definition-and-classification-of-power-system-stability-revisited-amp-extended-figure-3.png)