The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Placing Grid-Forming Converters to Enhance Small Signal Stability of PLL-Integrated Power Systems
Open accessAbstract
The modern power grid features the high penetration of power converters, which widely employ a phase-locked loop (PLL) for grid synchronization. However, it has been pointed out that PLL can give rise to small-signal instabilities under weak grid conditions. This problem can be potentially resolved by operating the converters in grid-forming mode, namely, without using a PLL. Nonetheless, it has not been theoretically revealed how the placement of grid-forming converters enhances the small-signal stability of power systems integrated with large-scale PLL-based converters. This paper aims at filling this gap. Based on matrix perturbation theory, we explicitly demonstrate that the placement of grid-forming converters is equivalent to increasing the power grid strength and thus improving the small-signal stability of PLL-based converters. Furthermore, we investigate the optimal locations to place grid-forming converters by increasing the smallest eigenvalue of the weighted and Kron-reduced Laplacian matrix of the power network. The analysis in this paper is validated through high-fidelity simulation studies on a modified two-area test system and a modified 39-bus test system. This paper potentially lays the foundation for understanding the interaction between PLL-based (i.e., grid-following) converters and grid-forming converters, and coordinating their placements in future converter-dominated power systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, R. A., & Johnson, C. R. (1985) · Cited by 22,203
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Horn, R. A., & Johnson, C. R. (2012) · doi:10.1017/cbo9781139020411 · Cited by 4,642
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
(1991) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(91)90038-5 · Cited by 2,437
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
1Kron Reduction of Graphs with Applications to Electrical Networks
Bullo, F. (2015) · Cited by 821
D’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704
Grid-Forming Inverters: Are They the Key for High Renewable Penetration?
Matevosyan, J., Badrzadeh, B., Prevost, T., Quitmann, E., Ramasubramanian, D., Urdal, H., Achilles, S., MacDowell, J., Huang, S. H., Vital, V., et al. (2019) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2019.2933072 · Cited by 472
D'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Poolla, B. K., Gros, D., & Dorfler, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892290 · Cited by 400
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
Self-citationComparison of Grid Following and Grid Forming Control for a High Inverter Penetration Power System
Pattabiraman, D., Lasseter., R. H., & Jahns, T. M. (2018) · 2018 IEEE Power & Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2018.8586162 · Cited by 304
Grid-forming control for power converters based on matching of synchronous machines
Arghir, C., Jouini, T., & Dörfler, F. (2018) · Automatica · doi:10.1016/j.automatica.2018.05.037 · Cited by 263
Huang, L., Xin, H., Li, Z., Ju, P., Yuan, H., Lan, Z., & Wang, Z. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2924295 · Cited by 252
Self-citationElectrical Networks and Algebraic Graph Theory: Models, Properties, and Applications
Dorfler, F., Simpson-Porco, J. W., & Bullo, F. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2821924 · Cited by 227
Modeling Type-4 Wind in Weak Grids
Fan, L. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2849849 · Cited by 182
The Effect of Transmission-Line Dynamics on Grid-Forming Dispatchable Virtual Oscillator Control
Gros, D., Colombino, M., Brouillon, J.-S., & Dorfler, F. (2019) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2019.2921347 · Cited by 168
Huang, L., Xin, H., & Dörfler, F. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.2984946 · Cited by 130
Self-citationHuang, L., Yang, C., Song, M., Yuan, H., Xie, H., Xin, H., & Wang, Z. (2019) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm40551.2019.8973583 · Cited by 25
Self-citation
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Metadata
- Authors
- Yang, C., Huang, L., Xin, H., & Ju, P.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2021-07
- Volume
- 36
- Issue
- 4
- Pages
- 3563-3573
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3041866734
- Cited by
- 279
- References
- 23
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.