The DOI matches its Crossref record.
Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope
Abstract
This paper proposes a magnetically actuated soft capsule endoscope (MASCE) as a tetherless miniature mobile robot platform for diagnostic and therapeutic medical applications inside the stomach. Two embedded internal permanent magnets and a large external magnet are used to actuate the robot remotely. The proposed MASCE has three novel features. First, its outside body is made of soft elastomer-based compliant structures. Such compliant structures can deform passively during the robot-tissue contact interactions, which makes the device safer and less invasive. Next, it can be actively deformed in the axial direction by using external magnetic actuation, which provides an extra degree of freedom that enables various advanced functions such as axial position control, drug releasing, drug injection, or biopsy. Finally, it navigates in three dimensions by rolling on the stomach surface as a new surface locomotion method inside the stomach. Here, the external attractive magnetic force is used to anchor the robot on a desired location, and the external magnetic torque is used to roll it to another location, which provides a stable, continuous, and controllable motion. The paper presents design and fabrication methods for the compliant structures of the robot with its axial deformation and position control capability. Rolling-based surface locomotion of the robot using external magnetic torques is modeled, and its feasibility is tested and verified on a synthetic stomach surface by using a magnetically actuated capsule endoscope prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Self-citationBiomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Biopsy with Thermally‐Responsive Untethered Microtools
Gultepe, E., Randhawa, J. S., Kadam, S., Yamanaka, S., Selaru, F. M., Shin, E. J., Kalloo, A. N., & Gracias, D. H. (2013) · Advanced Materials · doi:10.1002/adma.201203348 · Cited by 271
Metadata
- Authors
- Yim, S., & Sitti, M.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-02
- Volume
- 28
- Issue
- 1
- Pages
- 183-194
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2015705868
- Cited by
- 400
- References
- 0
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope. https://app.cochat.ai/papers/10.1109/tro.2011.2163861
- The paper
- Yim, S., & Sitti, M. (2012). Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2011.2163861
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.