The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope
Abstract
This paper proposes a magnetically actuated soft capsule endoscope (MASCE) as a tetherless miniature mobile robot platform for diagnostic and therapeutic medical applications inside the stomach. Two embedded internal permanent magnets and a large external magnet are used to actuate the robot remotely. The proposed MASCE has three novel features. First, its outside body is made of soft elastomer-based compliant structures. Such compliant structures can deform passively during the robot-tissue contact interactions, which makes the device safer and less invasive. Next, it can be actively deformed in the axial direction by using external magnetic actuation, which provides an extra degree of freedom that enables various advanced functions such as axial position control, drug releasing, drug injection, or biopsy. Finally, it navigates in three dimensions by rolling on the stomach surface as a new surface locomotion method inside the stomach. Here, the external attractive magnetic force is used to anchor the robot on a desired location, and the external magnetic torque is used to roll it to another location, which provides a stable, continuous, and controllable motion. The paper presents design and fabrication methods for the compliant structures of the robot with its axial deformation and position control capability. Rolling-based surface locomotion of the robot using external magnetic torques is modeled, and its feasibility is tested and verified on a synthetic stomach surface by using a magnetically actuated capsule endoscope prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Ciuti, G., Valdastri, P., Menciassi, A., & Dario, P. (2010) · Robotica · doi:10.1017/s0263574709990361 · Cited by 306
Modeling Magnetic Torque and Force for Controlled Manipulation of Soft-Magnetic Bodies
Abbott, J. J., Ergeneman, O., Kummer, M. P., Hirt, A. M., & Nelson, B. J. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910775 · Cited by 290
Capsule endoscopy: progress update and challenges ahead
Moglia, A., Menciassi, A., Dario, P., & Cuschieri, A. (2009) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2009.69 · Cited by 180
Development of a new engineering-based capsule for human drug absorption studies
Wilding, I. R., Hirst, P. H., & Connor, A. L. (2000) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(00)00311-4 · Cited by 122
Implementation of Multichannel Sensors for Remote Biomedical Measurements in a Microsystems Format
Johannessen, E. A., Wang, L., Li, C., Tang, T. B., Ahmadian, M., Astaras, A., Reid, S. W. J., Yam, P. S., Murray, A. F., Flynn, B. W., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820370 · Cited by 121
Fireman, Z., Glukhovsky, A., & Scapa, E. (2004) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/j.giec.2003.10.018 · Cited by 36
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Self-citationBiomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Magnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Multifunctional magnetic soft composites: a review
Wu, S., Hu, W., Ze, Q., Sitti, M., & Zhao, R. (2020) · Multifunctional Materials · doi:10.1088/2399-7532/abcb0c · Cited by 307
Self-citationYim, S., Gultepe, E., Gracias, D. H., & Sitti, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283369 · Cited by 292
Self-citationChallenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Biopsy with Thermally‐Responsive Untethered Microtools
Gultepe, E., Randhawa, J. S., Kadam, S., Yamanaka, S., Selaru, F. M., Shin, E. J., Kalloo, A. N., & Gracias, D. H. (2013) · Advanced Materials · doi:10.1002/adma.201203348 · Cited by 271
Nanomaterial Patterning in 3D Printing
Elder, B., Neupane, R., Tokita, E., Ghosh, U., Hales, S., & Kong, Y. L. (2020) · Advanced Materials · doi:10.1002/adma.201907142 · Cited by 265
A handheld device for magnetically inserting a neural interface into a peripheral nervous system
Yim, S., Hwang, D., Ihn, Y. S., Jeong, J., Oh, S.-R., & Kim, K. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036803 · Cited by 5
Self-citationPreliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4
Metadata
- Authors
- Yim, S., & Sitti, M.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-02
- Volume
- 28
- Issue
- 1
- Pages
- 183-194
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2015705868
- Cited by
- 400
- References
- 7
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.