Modeling, Identification, and Control of Tendon-Based Actuation Systems
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
In this paper, we deal with several aspects related to the control of tendon-based actuation systems for robotic devices. In particular, the problems that are considered in this paper are related to the modeling, identification, and control of tendons sliding on curved pathways, subject to friction and viscoelastic effects. Tendons made in polymeric materials are considered, and therefore, hysteresis in the transmission system characteristic must be taken into account as an additional nonlinear effect because of the plasticity and creep phenomena typical of these materials. With the aim of reproducing these behaviors, a viscoelastic model is used to model the tendon compliance. Particular attention has been given to the friction effects arising from the interaction between the tendon pathway and the tendon itself. This phenomenon has been characterized by means of a LuGre-like dynamic friction model to consider the effects that cannot be reproduced by employing a static friction model. A specific setup able to measure the tendon's tension in different points along its path has been designed in order to verify the tension distribution and identify the proper parameters. Finally, a simple control strategy for the compensation of these nonlinear effects and the control of the force that is applied by the tendon to the load is proposed and experimentally verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new model for control of systems with friction
Canudas de Wit, C., Olsson, H., Astrom, K. J., & Lischinsky, P. (1995) · IEEE Transactions on Automatic Control · doi:10.1109/9.376053 · Cited by 3,685 · cited 1×
“In the original formulation [41], the LuGre friction model considers a constant normal force between two bodies in relative motion.”
Friction Models and Friction Compensation
Olsson, H., Åström, K. J., Canudas de Wit, C., Gäfvert, M., & Lischinsky, P. (1998) · European Journal of Control · doi:10.1016/s0947-3580(98)70113-x · Cited by 1,581 · cited 3×
“In Section IV, the friction effects acting along the tendon are modeled by means of the LuGre dynamic model [36], which are suitably modified to cope with the characteristics of the tendon transmission system.”
BackgroundMethodInfluentialIntroduction to polymer viscoelasticity
(2005) · Choice Reviews Online · doi:10.5860/choice.43-2216 · Cited by 980
Robot Hands and the Mechanics of Manipulation
Mason, M. T., Salisbury, J. K., & Parker, J. K. (1989) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3153010 · Cited by 911
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 1×
“In this case, suitable models of the transmission system together with adequate control strategies are necessary; otherwise, only limited performance can be achieved [28], [29].”
BackgroundAn arm exoskeleton system for teleoperation and virtual environments applications
Bergamasco, M., Allotta, B., Bosio, L., Ferretti, L., Parrini, G., Prisco, G. M., Salsedo, F., & Sartini, G. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351286 · Cited by 196 · cited 1×
“…Hand [4], and the WAM manipulator [5], the robotic hands developed at the University of Bologna [6]–[8] and by Korean institutes [9], [10], to end effectors for surgical robots [11]–[13], haptic interfaces [14], exoskeletons [15], snake-like multijoint arms [16], and parallel manipulators [17].”
BackgroundModeling of Transmission Characteristics Across a Cable-Conduit System
Agrawal, V., Peine, W. J., & Yao, B. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2064014 · Cited by 167
The Effect of coulomb friction and stiction on force control
Townsend, W., & Salisbury, J. (2005) · Proceedings. 1987 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1987.1087936 · Cited by 160 · cited 1×
“The main drawback of the fixed-path tendon routing is the introduction of time-dependent backlash and distributed friction in the actuation, which is generated by tendon compliance and by the interaction between the tendon and the (curved) path [26], [27].”
BackgroundBasic considerations on transmission characteristics for tendon drive robots
Kaneko, M., Yamashita, T., & Tanie, K. (1991) · doi:10.1109/icar.1991.240572 · Cited by 135 · cited 5×
“This model has been first proposed in [30], where the tendon has been considered as a chain of masses m i , i = 1, . . . , N, which are connected by elastic elements and subject to the Coulomb friction represented in (4).”
BackgroundMethodInfluentialModel and control of tendon-sheath transmission systems
Palli, G., & Melchiorri, C. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641838 · Cited by 127 · cited 7×
“In [32], the analysis and the characterization of tendon-sheath transmission systems have been made with the assumption of using steel cables.”
BackgroundMethodInfluentialSelf-citation
Cited by
Integrated linkage-driven dexterous anthropomorphic robotic hand
Kim, U., Jung, D., Jeong, H., Park, J., Jung, H.-M., Cheong, J., Choi, H. R., Do, H., & Park, C. (2021) · Nature Communications · doi:10.1038/s41467-021-27261-0 · Cited by 228
A survey on actuators-driven surgical robots
Le, H. M., Do, T. N., & Phee, S. J. (2016) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2016.06.010 · Cited by 204
Palli, G., Melchiorri, C., Vassura, G., Scarcia, U., Moriello, L., Berselli, G., Cavallo, A., De Maria, G., Natale, C., Pirozzi, S., et al. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364913519897 · Cited by 186
“The use of sheaths is a convenient solution due to its simplicity, but it introduces distributed friction along the tendon, which introduces hysteresis and dead-zones in the transmission system characteristic (Kaneko et al., 1991; Palli et al., 2012a).”
BackgroundMethodResultInfluentialSelf-citationSimaan, N., Yasin, R. M., & Wang, L. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-104956 · Cited by 182
“A simple transmission model assuming Coulomb friction was presented in [54] and a dynamic friction model was used in [55] to incorporate viscoelastic properties of tendons.”
Method
Metadata
- Authors
- Palli, G., Borghesan, G., & Melchiorri, C.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-04
- Volume
- 28
- Issue
- 2
- Pages
- 277-290
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2085029715
- Cited by
- 179
- References
- 16
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.