A Protection Coordination Index for Evaluating Distributed Generation Impacts on Protection for Meshed Distribution Systems
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Depending on the capacity, type and location, distributed generation (DG) can have an impact on protection coordination of directional over-current relays for looped distribution systems. In this paper, a new index is proposed, “protection coordination index” (PCI), which can serve as an effective measure when planning the protection of meshed distribution systems with DG. A two-phase non-linear programming (NLP) optimization problem is proposed to determine the PCI by optimally calculating variations in the maximum DG penetration level with changes in the protection coordination time interval. Furthermore, the influence of connecting a DG at a certain location on the system PCIs is examined. The presented analysis is tested on the distribution section of the IEEE 14-bus and IEEE 30-bus systems. The PCI can serve as an efficient index for distribution system planners: (i) to determine the best DG candidate locations for utility owned DG and (ii) to evaluate the impact of a customer owned DG, considering distribution system protection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating Distributed Generation Impacts With a Multiobjective Index
Ochoa, L. F., Padilha-Feltrin, A., & Harrison, G. P. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.860262 · Cited by 384
A Modified Particle Swarm Optimizer for the Coordination of Directional Overcurrent Relays
Mansour, M. M., Mekhamer, S. F., & El-Kharbawe, N. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899259 · Cited by 347
Photovoltaic Generation Penetration Limits in Radial Distribution Systems
Shayani, R. A., & de Oliveira, M. A. G. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2077656 · Cited by 299
Communication Infrastructures for Distributed Control of Power Distribution Networks
Yang, Q., Barria, J. A., & Green, T. C. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2123903 · Cited by 298
El-Khattam, W., & Sidhu, T. S. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.915778 · Cited by 283
Impacts of distributed generation on power system transient stability
Slootweg, J. G., & Kling, W. L. (2003) · IEEE Power Engineering Society Summer Meeting, · doi:10.1109/pess.2002.1043465 · Cited by 259
Planning for Distributed Generation
Dugan, R. C., McDermott, T. E., & Ball, G. J. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.911193 · Cited by 230
A New Control Strategy to Mitigate the Impact of Inverter-Based DGs on Protection System
Yazdanpanahi, H., Li, Y. W., & Xu, W. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2184309 · Cited by 182
Ayres, H. M., Freitas, W., De Almeida, M. C., & Da Silva, L. C. P. (2010) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2009.0317 · Cited by 172
Optimal Distributed Voltage Regulation for Secondary Networks With DGs
Yu, L., Czarkowski, D., & de León, F. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2190308 · Cited by 172
Unsymmetrical Short-Circuit Fault Analysis for Weakly Meshed Distribution Systems
Teng, J. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036485 · Cited by 72
Neural Networks to Improve Distribution State Estimation—Volt Var Control Performances
Biserica, M. I., Bésanger, Y., Caire, R., Chilard, O., & Deschamps, P. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2193673 · Cited by 50
Optimal Sizing of Thyristor-Controlled Impedance for Smart Grids With Multiple Configurations
Zeineldin, H. H., El-Saadany, E. F., Salama, M. M. A., Alaboudy, A. H. K., & Woon, W. L. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2151213 · Cited by 24
Self-citation
Cited by
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Hooshyar, A., & Iravani, R. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2669342 · Cited by 435
Razavi, S.-E., Rahimi, E., Javadi, M. S., Nezhad, A. E., Lotfi, M., Shafie-khah, M., & Catalão, J. P. S. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.01.050 · Cited by 371
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Navigating the Complexities of Distributed Generation: Integration, Challenges, and Solutions
Saxena, V., Manna, S., Rajput, S. K., Kumar, P., Sharma, B., Alsharif, M. H., & Kim, M.-K. (2024) · Energy Reports · doi:10.1016/j.egyr.2024.09.017 · Cited by 82
Metadata
- Authors
- Zeineldin, H. H., Mohamed, Y. A.-R. I., Khadkikar, V., & Pandi, V. R.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2013-09
- Volume
- 4
- Issue
- 3
- Pages
- 1523-1532
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2046283704
- Cited by
- 159
- References
- 13
- FWCI
- 14.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.