Voltage Unbalance Reduction in Low Voltage Feeders by Dynamic Switching of Residential Customers Among Three Phases
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
To dynamically reduce voltage unbalance (VU) along low voltage distribution feeders, a distributed intelligent residential load transfer scheme is proposed. In this scheme, residential loads are transferred from one phase to another to minimize VU along the feeder. The central controller, installed at the distribution transformer, observes the power consumption in each house and determines the house(s) to be transferred from an initially connected phase to another. The transfer is carried out by the help of a static transfer switch, with a three-phase input and a single-phase output connection, through which each house is supplied. The steady-state and dynamic performances of the proposed load transfer scheme are investigated by MATLAB analyses and PSCAD/EMTDC simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Power Quality Enhancement Using Custom Power Devices
Ghosh, A., & Ledwich, G. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1153-3 · Cited by 1,365 · cited 2×
“Current unbalance andVoltageUnbalance (VU) are one of the mainpower quality problems in these feeders [2].”
BackgroundSelf-citationDistribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Smart meters for power grid: Challenges, issues, advantages and status
Depuru, S. S. S. R., Wang, L., & Devabhaktuni, V. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.02.039 · Cited by 567 · cited 1×
“For this, all the houses participating in the LT scheme are equipped with smart meters [19] that transmit the power consumption of the house to the central controller in 15-min intervals.”
MethodA survey of communication/networking in Smart Grids
Gao, J., Xiao, Y., Liu, J., Liang, W., & Chen, C. L. P. (2012) · Future Generation Computer Systems · doi:10.1016/j.future.2011.04.014 · Cited by 536
Electric power distribution handbook
(2004) · Choice Reviews Online · doi:10.5860/choice.41-4699 · Cited by 514
Faruqui, A., Harris, D., & Hledik, R. (2010) · Energy Policy · doi:10.1016/j.enpol.2010.06.010 · Cited by 337
Reconfiguration of Power Distribution Systems Considering Reliability and Power Loss
Amanulla, B., Chakrabarti, S., & Singh, S. N. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2179950 · Cited by 279 · cited 1×
“The main benefits of reconfiguration for the network are reducing the power loss [6], facilitating higher penetration level of distributed generation units [7], improving power quality [8] and faster restoration of service following a fault [9].”
BackgroundVoltage imbalance analysis in residential low voltage distribution networks with rooftop PVs
Shahnia, F., Majumder, R., Ghosh, A., Ledwich, G. F., & Zare, F. (2011) · Electric Power Systems Research · doi:10.1016/j.epsr.2011.05.001 · Cited by 151 · cited 3×
“Therefore, penetration level, rating and location of PVs in the feeder significantly affect the VU [3].”
BackgroundMethodSelf-citationThree-phase unbalance of distribution systems: Complementary analysis and experimental case study
Bina, M. T., & Kashefi, A. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.12.003 · Cited by 139 · cited 4×
“It is stated in [13] that in four-wire systems, zero sequence voltage often makes a larger contribution to phase voltage magnitude imbalance than negative sequence components.”
BackgroundInfluential
Cited by
Load Balancing With EV Chargers and PV Inverters in Unbalanced Distribution Grids
Weckx, S., & Driesen, J. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2015.2402834 · Cited by 235
Probabilistic assessment of hosting capacity in radial distribution systems
Abad, M. S. S., Ma, J., Zhang, D., Ahmadyar, A. S., & Marzooghi, H. (2018) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2819201 · Cited by 137
Nejabatkhah, F., & Li, Y. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2778508 · Cited by 76
On the impact of different voltage unbalance metrics in distribution system optimization
Girigoudar, K., & Roald, L. A. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106656 · Cited by 68
Nour, A. M. M., Hatata, A. Y., Helal, A. A., & El-Saadawi, M. M. (2018) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.5034000 · Cited by 9
Hou, Y., Givisiez, A. G., Liu, M. Z., & Ochoa, L. F. (2025) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2024.101615 · Cited by 7
Residential PV Hosting Capacity, Voltage Unbalance, and Power Rebalancing: An Australian Case Study
Hou, Y., Liu, M. Z., & Ochoa, L. F. (2022) · 2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe) · doi:10.1109/isgt-europe54678.2022.9960503 · Cited by 3
Metadata
- Authors
- Shahnia, F., Wolfs, P. J., & Ghosh, A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-05
- Volume
- 5
- Issue
- 3
- Pages
- 1318-1327
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2102467042
- Cited by
- 165
- References
- 17
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.