Intelligent Distributed Generation and Storage Units for DC Microgrids—A New Concept on Cooperative Control Without Communications Beyond Droop Control
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Low voltage dc microgrids have been widely used for supplying critical loads, such as data centers and remote communication stations. Consequently, it is important to ensure redundancy and enough energy capacity in order to support possible increments in load consumption. This is achieved by means of expansion of the energy storage system by adding extra distributed energy storage units. However, using distributed energy storage units adds more challenges in microgrids control, since stored energy should be balanced in order to avoid deep discharge or over-charge in one of the energy storage units. Typically, voltage droop loops are used for interconnecting several different units in parallel to a microgrid. This paper proposes a new decentralized strategy based on fuzzy logic that ensures stored energy balance for a low voltage dc microgrid with distributed battery energy storage systems by modifying the virtual resistances of the droop controllers in accordance with the state of charge of each energy storage unit. Additionally, the virtual resistance is adjusted in order to reduce the voltage deviation at the common dc bus. The units are self-controlled by using local variables only, hence, the microgrid can operate without relying on communication systems. Hardware in the loop results show the feasibility of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 1×
“In consequence, the battery with the lowest Rd will inject/extract more current in order to keep the power balance in the microgrid [23].”
BackgroundSelf-citationLinden, D. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,900
Supervisory Control of an Adaptive-Droop Regulated DC Microgrid With Battery Management Capability
Dragicevic, T., Guerrero, J. M., Vasquez, J. C., & Skrlec, D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257857 · Cited by 770
Self-citationSun, K., Zhang, L., Xing, Y., & Guerrero, J. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2127488 · Cited by 674
Self-citationVasquez, J. C., Guerrero, J. M., Savaghebi, M., Eloy-Garcia, J., & Teodorescu, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194951 · Cited by 666
Self-citationDC-Bus Signaling: A Distributed Control Strategy for a Hybrid Renewable Nanogrid
Schonbergerschonberger, J., Duke, R., & Round, S. D. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882012 · Cited by 573
Hierarchical Control of Intelligent Microgrids
Vasquez, J., Guerrero, J., Miret, J., Castilla, M., & Garcia de Vicuna, L. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.938720 · Cited by 471
Self-citationRahimi, A. M., & Emadi, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013748 · Cited by 461
Some Aspects of Stability in Microgrids
Majumder, R. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2234146 · Cited by 415
Distribution Voltage Control for DC Microgrids Using Fuzzy Control and Gain-Scheduling Technique
Kakigano, H., Miura, Y., & Ise, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2217353 · Cited by 391
Cited by
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Self-citationDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Self-citationDC Microgrid Planning, Operation, and Control: A Comprehensive Review
Al-Ismail, F. S. (2021) · IEEE Access · doi:10.1109/access.2021.3062840 · Cited by 542
Control Techniques in AC, DC, and Hybrid AC–DC Microgrid: A Review
Sahoo, S. K., Sinha, A. K., & Kishore, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2786588 · Cited by 534
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454
Hierarchical Control for Multiple DC-Microgrids Clusters
Shafiee, Q., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2362191 · Cited by 442
Self-citationSmart operations of smart grids integrated with distributed generation: A review
Kakran, S., & Chanana, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.045 · Cited by 427
Stability and Control Aspects of Microgrid Architectures–A Comprehensive Review
Ahmed, M., Meegahapola, L., Vahidnia, A., & Datta, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014977 · Cited by 326
Luna, A. C., Diaz, N. L., Graells, M., Vasquez, J. C., & Guerrero, J. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2581021 · Cited by 324
Self-citationPrimary and secondary control in DC microgrids: a review
GAO, F., KANG, R., CAO, J., & YANG, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-018-0466-5 · Cited by 314
A brief review on microgrids: Operation, applications, modeling, and control
Shahgholian, G. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12885 · Cited by 280
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
Hybrid ac/dc microgrids—Part II: Review and classification of control strategies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.186 · Cited by 254
Diaz, N. L., Luna, A. C., Vasquez, J. C., & Guerrero, J. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2606653 · Cited by 252
Self-citationReview of hierarchical control strategies for DC microgrid
Abhishek, A., Ranjan, A., Devassy, S., Kumar Verma, B., Ram, S. K., & Dhakar, A. K. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.1136 · Cited by 195
Cooperative Multi-Agent Control of Heterogeneous Storage Devices Distributed in a DC Microgrid
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2469725 · Cited by 166
“The most common charging strategy for lithium-ion and lead-acid batteries has two regions of operation, 1) a current-limited region below a maximum voltage, and 2) a constant voltage region at the float voltage [20].”
BackgroundLi, C., Coelho, E. A. A., Dragicevic, T., Guerrero, J. M., & Vasquez, J. C. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2645888 · Cited by 163
“For the first subcategory, the control is fully decentralized without any aids from the communication [10]–[12].”
BackgroundSelf-citationNonlinear Adaptive Backstepping Controller Design for Islanded DC Microgrids
Roy, T. K., Mahmud, M. A., Oo, A. M. T., Haque, M. E., Muttaqi, K. M., & Mendis, N. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2800680 · Cited by 163
“However, this is not the best solution when power electronics converters are connected to different devices, such as solar PV systems, wind generators, and BESSs with different sets of state of charges (SOCs) [19], [20].”
BackgroundA Multifunctional Single-Phase EV On-Board Charger With a New V2V Charging Assistance Capability
Taghizadeh, S., Hossain, M. J., Poursafar, N., Lu, J., & Konstantinou, G. (2020) · IEEE Access · doi:10.1109/access.2020.3004931 · Cited by 76
“The control method presented in [36] is used for HB2.”
Method
Metadata
- Authors
- Diaz, N. L., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-09
- Volume
- 5
- Issue
- 5
- Pages
- 2476-2485
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2080315331
- Cited by
- 309
- References
- 17
- FWCI
- 32.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.