Multilevel Energy Management System for Hybridization of Energy Storages in DC Microgrids
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Hybridization of energy storages (ESs) with different ramp rates helps minimization of system bus voltage variation and extension of ESs lifetime in dc microgrids. Hybrid ES system (HESS) control is normally realized with centralized coordination. In this paper, HESS distributed control, which is independent of the communication link, is proposed to enhance system reliability. All ESs are configured as slack terminals to regulate system bus voltage with droop control. System net power decomposition and ESs power sharing are realized with localized low-pass filter (LPF) applied to ESs with low-ramp rates. The relationship between LPF cut-off frequency and ES ramp rate is elaborated in detail. However, bus voltage deviation and power tracking errors are the main drawbacks of HESS distributed control. Multilevel energy management system (EMS) is thus proposed to enhance system control accuracy. HESS distributed control is scheduled as the primary control. Bus voltage restoration and power sharing compensation are applied in secondary control to eliminate the voltage deviation and power tracking errors, respectively. In tertiary control, autonomous state of charge (SoC) recovery is implemented to limit SoC variation of ES with high-ramp rate. A lab-scale dc microgrid is developed to verify the proposed multilevel EMS for HESS control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Anand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
Battery Energy Storage for Enabling Integration of Distributed Solar Power Generation
Hill, C. A., Such, M. C., Chen, D., Gonzalez, J., & Grady, W. M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2190113 · Cited by 799 · cited 1×
“ESs are always installed to compensate for system power imbalance [4], [5].”
BackgroundEnergy-management system for a hybrid electric vehicle, using ultracapacitors and neural networks
Moreno, J., Ortuzar, M. E., & Dixon, J. W. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.870880 · Cited by 748 · cited 1×
“HESS control algorithms can be categorized as passive [19], semi-active [20], [21], and active coordination [6].”
BackgroundZhou, H., Bhattacharya, T., Tran, D., Siew, T. S. T., & Khambadkone, A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095040 · Cited by 704
Power and life extension of battery-ultracapacitor hybrids
Dougal, R. A., Liu, S., & White, R. E. (2002) · IEEE Transactions on Components and Packaging Technologies · doi:10.1109/6144.991184 · Cited by 530 · cited 1×
“HESS control algorithms can be categorized as passive [19], semi-active [20], [21], and active coordination [6].”
BackgroundLi, W., Joos, G., & Belanger, J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037103 · Cited by 448 · cited 1×
“references for HRES and LRES accordingly in [22]–[25].”
BackgroundGu, Y., Xiang, X., Li, W., & He, X. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2294204 · Cited by 425 · cited 1×
“To ensure dc microgrid stability, at least one slack terminal should be online at all time for bus voltage regulation [31].”
BackgroundHierarchical Control of Parallel AC-DC Converter Interfaces for Hybrid Microgrids
Lu, X., Guerrero, J. M., Sun, K., Vasquez, J. C., Teodorescu, R., & Huang, L. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2272327 · Cited by 401 · cited 2×
“In this paper, all ESs are configured as slack terminals to eliminate the need for slack terminal reassignment in case of any ES outage [3], [32].”
BackgroundMethodDesign and Analysis of Novel Control Strategy for Battery and Supercapacitor Storage System
Kollimalla, S. K., Mishra, M. K., & Narasamma, N. L. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2336896 · Cited by 398
Cited by
Energy Management and Optimization Methods for Grid Energy Storage Systems
Byrne, R. H., Nguyen, T. A., Copp, D. A., Chalamala, B. R., & Gyuk, I. (2018) · IEEE Access · doi:10.1109/access.2017.2741578 · Cited by 406
Babu, T. S., Vasudevan, K. R., Ramachandaramurthy, V. K., Sani, S. B., Chemud, S., & Lajim, R. M. (2020) · IEEE Access · doi:10.1109/access.2020.3015919 · Cited by 354
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
Metadata
- Authors
- Xiao, J., Wang, P., & Setyawan, L.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015
- Pages
- 1-1
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2289870589
- Cited by
- 160
- References
- 35
- FWCI
- 13.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.