Load Control Using Sensitivity Identification by Means of Smart Transformer
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The higher variability introduced by distributed generation leads to fast changes in the aggregate load composition, and thus in the power response during voltage variations. The smart transformer, a power electronics-based distribution transformer with advanced control functionalities, can exploit the load dependence on voltage for providing services to the distribution and transmission grids. In this paper, two possible applications are proposed: 1) the smart transformer overload control by means of voltage control action and 2) the soft load reduction method, that reduces load consumption avoiding the load disconnection. These services depend on the correct identification of load dependence on voltage, which the smart transformer evaluates in real time based on load measurements. The effect of the distributed generation on net load sensitivity has been derived and demonstrated with the control hardware in loop evaluation by means of a real time digital simulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 1×
“The Smart Transformer is a three-stage power electronics transformer [17], [21] that adapts the voltage between the MV to the LV grid and provides new services to the distribution grid.”
BackgroundSelf-citation
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Ferreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303
Self-citationIntegration of Large Photovoltaic and Wind System by Means of Smart Transformer
Zhu, R., De Carne, G., Deng, F., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701758 · Cited by 71
Self-citationGorjian, A., Eskandari, M., & Moradi, M. H. (2023) · Energies · doi:10.3390/en16052502 · Cited by 19
Load-Dependent Active Thermal Control of Grid-Forming Converters
Andresen, M., De Carne, G., & Liserre, M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2966573 · Cited by 10
“To reduce the thermal stress for the semiconductors, the grid forming converter can exploit its voltage control feature to shape the load consumption in controlled way and thus to damp the power variations at grid forming converter level [8]–[10].”
BackgroundSelf-citation
Metadata
- Authors
- De Carne, G., Buticchi, G., Liserre, M., & Vournas, C.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-07
- Volume
- 9
- Issue
- 4
- Pages
- 2606-2615
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2529186219
- Cited by
- 110
- References
- 2
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.